circuit breaker 3VM1 IEC frame 100 breaking capacity class S
Icu=36kA @ 415V 3-pole, line protection TM210, FTFM, In=20A
overload protection Ir=20A, not adjustable short-circuit protection
Ii=16 x In nut keeper kit
Model
product brand name SENTRON
product designation Molded case circuit breaker
Product version Line protection
design of the overcurrent release TM210
protection function of the overcurrent release LI
number of poles 3
General technical data
Tension assignée d'isolement Ui 690 V
Max. rated operational voltage Ue with AC 50/60Hz 500 V
Max. rated operational voltage Ue with DC 250 V
power loss W / maximum 12 W
Active power loss / for rated value of the current / at
AC / in hot operating state / per pole
4 W
mechanical service life (switching cycles) / typical 10 000
Electrical endurance (switching cycles) / at AC-1 / at
380/415 V 50/60 Hz
2 000
Neutral conductors / upgradeable/retrofittable No
ground-fault monitoring version Without
product function
communication function No
other measurement function No
net weight 0.9 kg
Current
Max. rated operational current of the frame size 100 A
Courant permanent assigné Iu 20 A
operational current
at 40 degrees centigrade 20 A
at 45 degrees centigrade 20 A
at 50 degrees centigrade 20 A
at 55 degrees centigrade 20 A
at 60 degrees centigrade 19 A
at 65 degrees centigrade 19 A
at 70 degrees centigrade 18 A
Switching capacity according to IEC 60947
switching capacity class of the circuit breaker S
breaking capacity maximum short-circuit current (Icu)
at 240 V 55 kA
at 415 V 36 kA
at 440 V 20 kA
at 500 V 7 kA
breaking capacity operating short-circuit current (Ics)
at 240 V 18 kA
at 415 V 12 kA
at 440 V 8 kA
at 500 V 2.5 kA
short-circuit current making capacity (Icm)
at 240 V 121 kA
at 415 V 76 kA
at 440 V 40 kA
at 500 V 11.9 kA
design of short-circuit protection For switching capacity values in DC power systems, see the 3VA
Molded Case Circuit Breaker Manual; link available under Service
& Support in the last chapter
Adjustable parameters
Adjustable response value current / lg min. 20 A
Adjustable response value current / lg min. 20 A
Short-term delayed / tripping switchable /
I2t=ON/OFF
No
Adjustable response value current / li min. 320 A
Adjustable response value current / li max. 320 A
Ground fault protection / tripping switchable /
I2t=ON/OFF
No
circuit breaker 3VM1 IEC frame 100 breaking capacity class S
Icu=36kA @ 415V 3-pole, line protection TM210, FTFM, In=20A
overload protection Ir=20A, not adjustable short-circuit protection
Ii=16 x In nut keeper kit
Model
product brand name SENTRON
product designation Molded case circuit breaker
Product version Line protection
design of the overcurrent release TM210
protection function of the overcurrent release LI
number of poles 3
General technical data
Tension assignée d'isolement Ui 690 V
Max. rated operational voltage Ue with AC 50/60Hz 500 V
Max. rated operational voltage Ue with DC 250 V
power loss W / maximum 12 W
Active power loss / for rated value of the current / at
AC / in hot operating state / per pole
4 W
mechanical service life (switching cycles) / typical 10 000
Electrical endurance (switching cycles) / at AC-1 / at
380/415 V 50/60 Hz
2 000
Neutral conductors / upgradeable/retrofittable No
ground-fault monitoring version Without
product function
communication function No
other measurement function No
net weight 0.9 kg
Current
Max. rated operational current of the frame size 100 A
Courant permanent assigné Iu 20 A
operational current
at 40 degrees centigrade 20 A
at 45 degrees centigrade 20 A
at 50 degrees centigrade 20 A
at 55 degrees centigrade 20 A
at 60 degrees centigrade 19 A
at 65 degrees centigrade 19 A
at 70 degrees centigrade 18 A
Switching capacity according to IEC 60947
switching capacity class of the circuit breaker S
breaking capacity maximum short-circuit current (Icu)
at 240 V 55 kA
at 415 V 36 kA
at 440 V 20 kA
at 500 V 7 kA
breaking capacity operating short-circuit current (Ics)
at 240 V 18 kA
at 415 V 12 kA
at 440 V 8 kA
at 500 V 2.5 kA
short-circuit current making capacity (Icm)
at 240 V 121 kA
at 415 V 76 kA
at 440 V 40 kA
at 500 V 11.9 kA
design of short-circuit protection For switching capacity values in DC power systems, see the 3VA
Molded Case Circuit Breaker Manual; link available under Service
& Support in the last chapter
Adjustable parameters
Adjustable response value current / lg min. 20 A
Adjustable response value current / lg min. 20 A
Short-term delayed / tripping switchable /
I2t=ON/OFF
No
Adjustable response value current / li min. 320 A
Adjustable response value current / li max. 320 A
Ground fault protection / tripping switchable /
I2t=ON/OFF
No
Las personas que compraron este artículo también vieron
Fuji Disyuntor EW32AAG-3P030
US$113.85
Schneider Disyuntor LS8F18140G
US$125.00
Eaton Moeller Disyuntor LZMS3-A500+NZM3-XAV
US$2022.06
Siemens Disyuntor 3RV2021-1HA10
US$238.68
TRIAD Transformador F-3185U
US$88.46
ALBRIGHT Contactor SW200-802
US$146.15
Littelfuse Fusible 0453010.DR
US$0.77
TYCO Relé OJ-SS-112DM
US$2.69
UniOhm Resistor 1210W2J0433T5E
US$2.31
Los clientes ven con frecuencia
Carel Válvula de expansión E6VB2ASV00
US$839.00
Mitsubishi Compresor RE277NRAMT
US$389.00
Togami Contactor CLK-25J3
US$79.00
PIZZATO Interruptor NB B112KP-SMK
US$230.77
Delta Servo Motor ECMA-C10401SS
US$1125.28
TOWARD Relé LRL-102PCZ-14KV
US$64.62
Publicaciones relacionadas recientes
-
06/27/2023
Principio de funcionamiento del compresor frigorífico, esquema eléctrico, estructura
El componente principal del refrigerador es el compresor. Si un frigorífico no está equipado con un compresor de buena calidad y tecnología no puede ser un buen frigorífico.
-
01/07/2024
¿Por qué vibra el servomotor?
¿En qué casos vibrará un servomotor? ¿Qué pasa si el servomotor vibra? ¿Cómo podemos solucionar los problemas causados por la vibración? Este artículo explicará varias razones para esto.
-
05/19/2022
17 fabricantes de compresores centrífugos, en el mundo. ¿cuántos conoce?
En la última década, en un contexto de globalización económica y feroz competencia, la industria de fabricación de compresores centrífugos también ha experimentado continuas fusiones, adquisiciones y reorganizaciones.
-
08/08/2023
Método de cálculo del peso por metro de tubo de cobre para aire acondicionado
Método de cálculo del peso por metro de tubería de cobre para aire acondicionado.
-
02/17/2024
Método de cableado del relé PTC de nevera
El relé PTC (coeficiente de temperatura positivo) está conectado directamente en serie con el devanado secundario (devanado de arranque) y en paralelo con el devanado principal del motor.
-
05/11/2022
Reparación de averías en servoaccionamientos Ultra3000
Hemos enumerado las fallas comunes y los métodos de reparación de los servovariadores Ultra3000; si necesita reemplazar el equipo, le brindamos Servoaccionamiento Allen Bradley Rockwell.
-
11/18/2023
Transmisores Rosemount Series 1151, 2088, 2051, 3051CA, 3051S y sus diferencias
El transmisor de presión Rosemount es un tipo de transmisor de presión general. Está fabricado según la ley de inducción electromagnética y la norma JB/T9248-1999.
-
08/04/2023
Aire acondicionado Mitsubishi vs Panasonic
El verano es tan difícil de pasar que las personas sin aire acondicionado son como peces fuera del agua. Es fundamental elegir un buen aire acondicionado.
-
03/10/2024
Todo lo que debe saber sobre el embrague magnético del compresor de CA del coche
Este artículo presenta los componentes del embrague magnético del compresor y su principio de funcionamiento, así como varios parámetros importantes. Además, también le brindamos algunas experiencias sobre cómo lidiar con la quema de los embragues del compresor del aire acondicionado.
-
07/29/2023
Compresor Scroll Vs. Compresor rotativo para CA
El compresor scrollue inventado en 1905 por el francés Copeland. Creó la compañía Copeland en los Estados Unidos, donde se utilizan principalmente acondicionadores de aire de agua