Siemens Disyuntor 3VA1112-5EF32-0AA0
$ 410 .16
(5) 1
Comentarios
Cantidad
MOQ : 1
Pagos
Parámetro
Tipo | 3VA1 |
Tipo de disyuntor | 3VA Molded Case Circuit Breakers |
Diseñoación de disyuntor | Thermal magnetic breakers |
Marco Tamaño | 160A |
Corriente Nominal | 125 A |
Interrupting Capacidad | 55 kA |
Número de polos | 3 pole |
Conexión Tecnologías / Destacados | Nut keeper kit |
Detalles regionales | Standard |
¡El Siemens Circuit Breaker es de alta calidad!
circuit breaker 3VA1 IEC frame 160 breaking capacity class M
Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A
overload protection Ir=88A...125A short-circuit protection Ii=5...10 x
In nut keeper kit
Model
product brand name SENTRON
product designation Molded case circuit breaker
Product version Line protection
design of the overcurrent release TM240
protection function of the overcurrent release LI
number of poles 3
General technical data
Tension assignée d'isolement Ui 800 V
Max. rated operational voltage Ue with AC 50/60Hz 690 V
Max. rated operational voltage Ue with DC 500 V
power loss W / maximum 28.1 W
Active power loss / for rated value of the current / at
AC / in hot operating state / per pole
9.37 W
mechanical service life (switching cycles) / typical 20 000
Electrical endurance (switching cycles) / at AC-1 / at
380/415 V 50/60 Hz
8 000
Electrical endurance (switching cycles) / at AC-1 / at
690 V 50/60 Hz
8 000
Neutral conductors / upgradeable/retrofittable No
ground fault monitoring version Without
product function
communication function No
other measurement function No
net weight 0.9 kg
Current
Max. rated operational current of the frame size 160 A
Courant permanent assigné Iu 125 A
operating current
at 40 degrees centigrade 125 A
at 45 degrees centigrade 125 A
at 50 degrees centigrade 125 A
at 55 degrees centigrade 122 A
at 60 degrees centigrade 120 A
at 65 degrees centigrade 117 A
at 70 degrees centigrade 114 A
Switching capacity according to IEC 60947
switching capacity class of the circuit breaker M
maximum short-circuit current breaking capacity (Icu)
at 240 V 85 kA
at 415 V 55 kA
at 440 V 36 kA
at 500 V 10 kA
at 690 V 10 kA
operational short-circuit current breaking capacity
(Ics)
at 240 V 85 kA
at 415 V 55 kA
at 440 V 36 kA
at 500 V 5 kA
at 690 V 5 kA
short-circuit current making capacity (Icm)
at 240 V 187 kA
at 415 V 121 kA
at 440 V 76 kA
at 500 V 17 kA
at 690 V 17 kA
design of short-circuit protection For switching power values in DC networks, see the 3VA molded
case circuit breaker device manual; link to be found under Service
& Support in the last chapter
Adjustable parameters
Adjustable response value current / lg min. 88 A
Adjustable response value current / lg min. 125 A
Short-term delayed / tripping switchable /
I2t=ON/OFF
No
Adjustable response value current / li min. 625 A
Adjustable response value current / li max. 1 250 A
Ground fault protection / tripping switchable /
I2t=ON/OFF
No
Mechanical Design
height in 5.1 in
Height 130 mm
width in 3 in
Width 76.2 mm
depth in 2.8 in
depth 70 mm
Connections
arrangement of electrical connectors / for main
current circuit
Front terminal
Type of connectable conductor cross-section,
connection screw, width x thickness , min.
12 x 0 mm
Type of connectable conductor cross-section,
connection screw, width x thickness , max.
17 x 6.5 mm
Auxiliary circuit
number of CO contacts / for auxiliary contacts 0
Accessories
product extension / optional / motor drive Yes
Environmental conditions
protection class IP / on the front IP40
ambient temperature
during operation / minimum -25 degrees centigrade
during operation / maximum 70 degrees centigrade
during storage / minimum -40 degrees centigrade
during storage / maximum 80 degrees centigrade
Certificates
reference code / acc. to DIN EN 81346-2 Q
circuit breaker 3VA1 IEC frame 160 breaking capacity class M
Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A
overload protection Ir=88A...125A short-circuit protection Ii=5...10 x
In nut keeper kit
Model
product brand name SENTRON
product designation Molded case circuit breaker
Product version Line protection
design of the overcurrent release TM240
protection function of the overcurrent release LI
number of poles 3
General technical data
Tension assignée d'isolement Ui 800 V
Max. rated operational voltage Ue with AC 50/60Hz 690 V
Max. rated operational voltage Ue with DC 500 V
power loss W / maximum 28.1 W
Active power loss / for rated value of the current / at
AC / in hot operating state / per pole
9.37 W
mechanical service life (switching cycles) / typical 20 000
Electrical endurance (switching cycles) / at AC-1 / at
380/415 V 50/60 Hz
8 000
Electrical endurance (switching cycles) / at AC-1 / at
690 V 50/60 Hz
8 000
Neutral conductors / upgradeable/retrofittable No
ground fault monitoring version Without
product function
communication function No
other measurement function No
net weight 0.9 kg
Current
Max. rated operational current of the frame size 160 A
Courant permanent assigné Iu 125 A
operating current
at 40 degrees centigrade 125 A
at 45 degrees centigrade 125 A
at 50 degrees centigrade 125 A
at 55 degrees centigrade 122 A
at 60 degrees centigrade 120 A
at 65 degrees centigrade 117 A
at 70 degrees centigrade 114 A
Switching capacity according to IEC 60947
switching capacity class of the circuit breaker M
maximum short-circuit current breaking capacity (Icu)
at 240 V 85 kA
at 415 V 55 kA
at 440 V 36 kA
at 500 V 10 kA
at 690 V 10 kA
operational short-circuit current breaking capacity
(Ics)
at 240 V 85 kA
at 415 V 55 kA
at 440 V 36 kA
at 500 V 5 kA
at 690 V 5 kA
short-circuit current making capacity (Icm)
at 240 V 187 kA
at 415 V 121 kA
at 440 V 76 kA
at 500 V 17 kA
at 690 V 17 kA
design of short-circuit protection For switching power values in DC networks, see the 3VA molded
case circuit breaker device manual; link to be found under Service
& Support in the last chapter
Adjustable parameters
Adjustable response value current / lg min. 88 A
Adjustable response value current / lg min. 125 A
Short-term delayed / tripping switchable /
I2t=ON/OFF
No
Adjustable response value current / li min. 625 A
Adjustable response value current / li max. 1 250 A
Ground fault protection / tripping switchable /
I2t=ON/OFF
No
Mechanical Design
height in 5.1 in
Height 130 mm
width in 3 in
Width 76.2 mm
depth in 2.8 in
depth 70 mm
Connections
arrangement of electrical connectors / for main
current circuit
Front terminal
Type of connectable conductor cross-section,
connection screw, width x thickness , min.
12 x 0 mm
Type of connectable conductor cross-section,
connection screw, width x thickness , max.
17 x 6.5 mm
Auxiliary circuit
number of CO contacts / for auxiliary contacts 0
Accessories
product extension / optional / motor drive Yes
Environmental conditions
protection class IP / on the front IP40
ambient temperature
during operation / minimum -25 degrees centigrade
during operation / maximum 70 degrees centigrade
during storage / minimum -40 degrees centigrade
during storage / maximum 80 degrees centigrade
Certificates
reference code / acc. to DIN EN 81346-2 Q
Las personas que compraron este artículo también vieron
Schneider Disyuntor LS8Z11250
US$625.00
Schneider Disyuntor EA9A47C50
US$125.00
Terasaki Disyuntor ZS50-NF HI
US$123.08
Schneider Disyuntor GV2-ME07C
US$625.00
CHINT Transformador QZB-J-115
US$462.50
Schneider Contactor LC1N50M5N
US$182.69
Littelfuse Fusible 0891020.NXWS
US$0.77
HONGFA Relé HFV7-024-H4STM
US$6.54
EBG Resistor UXP-250-2R
US$72.70
Los clientes ven con frecuencia
Carel Válvula de expansión E6VB2ASV00
US$839.00
Mitsubishi Compresor RE277NRAMT
US$389.00
Togami Contactor CLK-25J3
US$79.00
NMB Sensor PRB-30MP
US$3076.92
Hossoni Fuente de alimentación CWY-500VA
US$573.83
Yaskawa Servo Motor SGMSV-20ADA6C
US$1500.00
OEG Relé OJ-SH-112HM
US$0.85
Publicaciones relacionadas recientes
-
05/19/2022
17 fabricantes de compresores centrífugos, en el mundo. ¿cuántos conoce?
En la última década, en un contexto de globalización económica y feroz competencia, la industria de fabricación de compresores centrífugos también ha experimentado continuas fusiones, adquisiciones y reorganizaciones.
-
08/08/2023
Método de cálculo del peso por metro de tubo de cobre para aire acondicionado
Método de cálculo del peso por metro de tubería de cobre para aire acondicionado.
-
03/10/2024
Todo lo que debe saber sobre el embrague magnético del compresor de CA del coche
Este artículo presenta los componentes del embrague magnético del compresor y su principio de funcionamiento, así como varios parámetros importantes. Además, también le brindamos algunas experiencias sobre cómo lidiar con la quema de los embragues del compresor del aire acondicionado.
-
08/04/2023
Aire acondicionado Mitsubishi vs Panasonic
El verano es tan difícil de pasar que las personas sin aire acondicionado son como peces fuera del agua. Es fundamental elegir un buen aire acondicionado.
-
02/17/2024
Método de cableado del relé PTC de nevera
El relé PTC (coeficiente de temperatura positivo) está conectado directamente en serie con el devanado secundario (devanado de arranque) y en paralelo con el devanado principal del motor.
-
01/07/2024
¿Por qué vibra el servomotor?
¿En qué casos vibrará un servomotor? ¿Qué pasa si el servomotor vibra? ¿Cómo podemos solucionar los problemas causados por la vibración? Este artículo explicará varias razones para esto.
-
11/18/2023
Transmisores Rosemount Series 1151, 2088, 2051, 3051CA, 3051S y sus diferencias
El transmisor de presión Rosemount es un tipo de transmisor de presión general. Está fabricado según la ley de inducción electromagnética y la norma JB/T9248-1999.
-
07/29/2023
Compresor Scroll Vs. Compresor rotativo para CA
El compresor scrollue inventado en 1905 por el francés Copeland. Creó la compañía Copeland en los Estados Unidos, donde se utilizan principalmente acondicionadores de aire de agua
-
12/05/2023
Principios y diferencias de los transmisores de 2, 3 y 4 hilos
Los transmisores de 2, 3 y 4 hilos se refieren a transmisores cuyas salidas son señales analógicas de corriente CC.
-
06/27/2023
Principio de funcionamiento del compresor frigorífico, esquema eléctrico, estructura
El componente principal del refrigerador es el compresor. Si un frigorífico no está equipado con un compresor de buena calidad y tecnología no puede ser un buen frigorífico.