Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 1.25 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 0.9...1.25 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S00 for motor protection, CLASS 10 with
overload relay function A-release 0.9...1.25 A N-release 16 A screw
terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection with overload relay function
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25?W
at AC in hot operating state per pole 2.4?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
0.9?...?1.25?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 1.25?A
operating current
at AC-3
at 400 V rated value 1.25?A
operating power
at AC-3
at 230 V rated value 180?W
at 400 V rated value 370?W
at 500 V rated value 370?W
at 690 V rated value 750?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch laterally
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 1.5?A
at 230 V 1.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 100?kA
at 500 V rated value 100?kA
at 690 V rated value 100?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 100?kA
at AC at 690 V rated value 100?kA
response value current
of instantaneous short-circuit trip unit 16?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 1.25?A
at 600 V rated value 1.25?A
yielded mechanical performance hp
for three-phase AC motor
at 460/480 V rated value 0.5?hp
at 575/600 V rated value 0.5?hp
contact rating of auxiliary contacts according to UL C600 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gL/gG: 6 A, quick: 10 A
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 500 V gL/gG 16 A
at 690 V gL/gG 16 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97?mm
width 65?mm
depth 97?mm
Circuit breaker size S00 for motor protection, CLASS 10 with
overload relay function A-release 0.9...1.25 A N-release 16 A screw
terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection with overload relay function
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25?W
at AC in hot operating state per pole 2.4?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
0.9?...?1.25?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 1.25?A
operating current
at AC-3
at 400 V rated value 1.25?A
operating power
at AC-3
at 230 V rated value 180?W
at 400 V rated value 370?W
at 500 V rated value 370?W
at 690 V rated value 750?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch laterally
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 1.5?A
at 230 V 1.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 100?kA
at 500 V rated value 100?kA
at 690 V rated value 100?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 100?kA
at AC at 690 V rated value 100?kA
response value current
of instantaneous short-circuit trip unit 16?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 1.25?A
at 600 V rated value 1.25?A
yielded mechanical performance hp
for three-phase AC motor
at 460/480 V rated value 0.5?hp
at 575/600 V rated value 0.5?hp
contact rating of auxiliary contacts according to UL C600 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gL/gG: 6 A, quick: 10 A
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 500 V gL/gG 16 A
at 690 V gL/gG 16 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97?mm
width 65?mm
depth 97?mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo buscar productos en el sitio web?
Responder: Puede utilizar la barra de búsqueda ubicada en la parte superior del sitio web para ingresar palabras clave y encontrar los productos deseados. Alternativamente, puede navegar a través de diferentes categorías y filtrar opciones para limitar su búsqueda.
- Consulta: ¿Admiten envíos internacionales?
Responder: Sí, admitimos envíos internacionales. Puede seleccionar la opción de envío internacional y proporcionar la dirección de envío correspondiente durante el proceso de pago. Tenga en cuenta que el envío internacional puede requerir tarifas y tiempo adicionales.
- Consulta: ¿Cómo puedo verificar el estado de mi artículo pendiente?
Responder: Para verificar el estado de su artículo pendiente, comuníquese con nuestro equipo de servicio al cliente. Le proporcionarán la información más reciente sobre la disponibilidad y la fecha estimada de envío del artículo.
Comentarios
- J
Joan Kelly
01/07/2025
Siemens Disyuntor 3RV2111-0KA10That's the ticket!ÚtilNo ayuda - J
Jed Milhorne
23/06/2025
Siemens Disyuntor 3RV2111-0KA10That's the way to go, buddy!ÚtilNo ayuda - I
Ivaylo Djambov
27/12/2024
Siemens Disyuntor 3RV2111-0KA10The price was amazing, and the shipping was still super quick.ÚtilNo ayuda - E
Enrique
10/04/2024
Siemens Disyuntor 3RV2111-0KA10quick and easy - found partÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2111-0KA10¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2111-0KA10
$ 373 .45
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Fuji Disyuntor BW32AAG-3P032
US$53.46
Fuji Disyuntor EG203C-3P125A
US$189.00
Fuji Disyuntor EW63EAG-3P063B
US$182.69
Eaton Moeller Disyuntor PL9-C2-DC
US$27.57
TRIAD Transformador F-254X
US$71.98
Fuji Contactor SC-N4-SE
US$590.00
Littelfuse Fusible KLQ1
US$34.50
TYCO Relé T92S7D22-22
US$19.23
UniOhm Resistor 0402WGJ0562TCE
US$4.81
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Danfoss Bomba de engranajes SNM2NN019
Contacta con nosotros
Kuebler Codificador 8.5020.8A5A.0050
Contacta con nosotros
Copeland Compresor CR35K6E-TFD-201WB
Contacta con nosotros
Omron PLC CQM1-CIF02
US$1725.00
EATON Relé DILA-22(110VDC)
US$138.00
Contrinex Sensor DW-AS-502-M5
US$76.92
Copeland Compresor ZPT144KCE-TF7-275
Contacta con nosotros