Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 75 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 57...75 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S3 for motor protection, Class 20 A-release
57...75 A N-release 975 A screw terminal Increased switching
capacity 100 kA
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S3
size of contactor can be combined company-specific S3
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 38?W
at AC in hot operating state per pole 12.7?W
insulation voltage with degree of pollution 3 at AC
rated value
1?000?V
surge voltage resistance rated value 8?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 25?000
of auxiliary contacts typical 25?000
electrical endurance (switching cycles)
typical 25?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
57?...?75?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 75?A
operating current
at AC-3
at 400 V rated value 75?A
operating power
at AC-3
at 230 V rated value 22?000?W
at 400 V rated value 37?000?W
at 500 V rated value 45?000?W
at 690 V rated value 55?000?W
operating frequency
at AC-3 maximum 15?1/h
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class Class 20
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 5?kA
at 690 V rated value 3?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 975?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 75?A
at 600 V rated value 75?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 7.5?hp
at 230 V rated value 15?hp
for three-phase AC motor
at 200/208 V rated value 25?hp
at 220/230 V rated value 30?hp
at 460/480 V rated value 60?hp
at 575/600 V rated value 75?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 165?mm
width 70?mm
depth 176?mm
Circuit breaker size S3 for motor protection, Class 20 A-release
57...75 A N-release 975 A screw terminal Increased switching
capacity 100 kA
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S3
size of contactor can be combined company-specific S3
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 38?W
at AC in hot operating state per pole 12.7?W
insulation voltage with degree of pollution 3 at AC
rated value
1?000?V
surge voltage resistance rated value 8?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 25?000
of auxiliary contacts typical 25?000
electrical endurance (switching cycles)
typical 25?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
57?...?75?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 75?A
operating current
at AC-3
at 400 V rated value 75?A
operating power
at AC-3
at 230 V rated value 22?000?W
at 400 V rated value 37?000?W
at 500 V rated value 45?000?W
at 690 V rated value 55?000?W
operating frequency
at AC-3 maximum 15?1/h
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class Class 20
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 5?kA
at 690 V rated value 3?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 975?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 75?A
at 600 V rated value 75?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 7.5?hp
at 230 V rated value 15?hp
for three-phase AC motor
at 200/208 V rated value 25?hp
at 220/230 V rated value 30?hp
at 460/480 V rated value 60?hp
at 575/600 V rated value 75?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 165?mm
width 70?mm
depth 176?mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo consultar la fecha de producción o fecha de vencimiento de un producto?
Responder: Para comprobar la fecha de producción o la fecha de caducidad de un producto, puede consultar el embalaje o las etiquetas del producto. Proporcionamos información clara y precisa sobre la fecha de fabricación y la fecha de vencimiento, lo que le permite tomar decisiones de compra informadas. Si necesita más ayuda, nuestro equipo de atención al cliente siempre está listo para ayudar.
- Consulta: ¿El producto tiene garantía de calidad?
Responder: ¡Absolutamente! Estamos orgullosos de ofrecer productos de alta calidad. Cada producto se somete a rigurosos controles de calidad para garantizar la excelencia y la satisfacción del cliente. Respaldamos la calidad de nuestros productos.
- Consulta: ¿Cómo puedo enviar comentarios o reseñar un producto?
Responder: Puede proporcionar comentarios o reseñar un producto accediendo a la página del producto y haciendo clic en la opción "Escribir una reseña" o "Dejar comentarios". Comparta su experiencia y opiniones para ayudar a otros compradores a tomar decisiones informadas.
Comentarios
- K
KAREN VOGT
08/07/2025
Siemens Disyuntor 3RV2042-4KB10Thanks for being so responsive and helpful with this order.ÚtilNo ayuda - S
Sally Ryan
30/06/2025
Siemens Disyuntor 3RV2042-4KB10All's in the green.ÚtilNo ayuda - R
Ramon Pitt
01/11/2024
Siemens Disyuntor 3RV2042-4KB10Fast and efficientÚtilNo ayuda - F
Fernanda
11/08/2024
Siemens Disyuntor 3RV2042-4KB10Ordering was easy. Found what I needed at a reasonable price. Thank you!ÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2042-4KB10¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2042-4KB10
$ 1,207 .50
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Fuji Disyuntor EW50RAGU-3P030B
US$626.92
Fuji Disyuntor EG203C-3P175A
US$141.15
Siemens Disyuntor 3RV1011-1KA10
US$363.07
Siemens Disyuntor 3RV2021-4BA10
US$277.79
Delixi Transformador JBK-63VA
US$27.50
Eaton Contactor DLLM300
US$1346.15
Ferraz Shawmut Fusible PC33UD45V2500TF
US$423.08
AIKS Relé AR302F-F DC24V
US$10.15
Siemens Resistor 6SE6400-4BD21-2DA0
US$877.31
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Copeland Compresor RS64C1E-CAA-211
Contacta con nosotros
ANSON Bomba de paletas IVPV1-12AM-L-L-A-10
Contacta con nosotros
Bristol Compresor H20B283ABJ
US$563.38
INFINEON IGBT Módulo FF600R12KE4
US$332.00
NMB Cojinete DDL-1910ZZ
US$8.65
ORION Ventilador OD1238-24MBXC
US$66.80
ULVAC Bomba de Vacío PMB600DT-MD2J1F1I4XX
Contacta con nosotros
Schneider Contactor LC1D066BD
Contacta con nosotros