Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 40 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 32...40 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S2 for motor protection, CLASS 10 A-release
9.5...14 A N-release 208 A screw terminal increased switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 12.5?W
at AC in hot operating state per pole 4.2?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
9.5?...?14?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 14?A
operating current
at AC-3
at 400 V rated value 14?A
operating power
at AC-3
at 230 V rated value 3?000?W
at 400 V rated value 5?500?W
at 500 V rated value 7?500?W
at 690 V rated value 11?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 10?kA
at 690 V rated value 5?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 18?kA
at AC at 690 V rated value 8?kA
response value current
of instantaneous short-circuit trip unit 208?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 14?A
at 600 V rated value 14?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 1.5?hp
at 230 V rated value 3?hp
for three-phase AC motor
at 200/208 V rated value 5?hp
at 220/230 V rated value 5?hp
at 460/480 V rated value 10?hp
at 575/600 V rated value 15?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 100
at 500 V 80
at 690 V 63
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Circuit breaker size S2 for motor protection, CLASS 10 A-release
9.5...14 A N-release 208 A screw terminal increased switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 12.5?W
at AC in hot operating state per pole 4.2?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
9.5?...?14?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 14?A
operating current
at AC-3
at 400 V rated value 14?A
operating power
at AC-3
at 230 V rated value 3?000?W
at 400 V rated value 5?500?W
at 500 V rated value 7?500?W
at 690 V rated value 11?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 10?kA
at 690 V rated value 5?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 18?kA
at AC at 690 V rated value 8?kA
response value current
of instantaneous short-circuit trip unit 208?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 14?A
at 600 V rated value 14?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 1.5?hp
at 230 V rated value 3?hp
for three-phase AC motor
at 200/208 V rated value 5?hp
at 220/230 V rated value 5?hp
at 460/480 V rated value 10?hp
at 575/600 V rated value 15?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 100
at 500 V 80
at 690 V 63
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo filtrar productos por rango de precios?
Responder: En la página de listado de productos, puede utilizar la herramienta de filtrado de precios para establecer el rango de precios deseado. El sistema mostrará los productos que cumplan con sus criterios, ayudándole a encontrar los artículos adecuados rápidamente.
- Consulta: ¿Cómo puedo consultar la cobertura de garantía de un producto?
Responder: La cobertura de garantía de un producto generalmente se especifica en la página de detalles del producto o en la información de garantía proporcionada por el fabricante. Puede revisar esta información antes de realizar una compra para comprender la cobertura de la garantía.
- Consulta: ¿Qué debo hacer si recibo un producto dañado o defectuoso?
Responder: En el raro caso de que reciba un producto dañado o defectuoso, comuníquese con nuestro servicio de atención al cliente de inmediato. Le ayudaremos a resolver el problema organizando una devolución, reemplazo o reparación, según las circunstancias.
Comentarios
- M
Mack Crane
15/10/2025
Siemens Disyuntor 3RV2032-4SA15They stocked the tool I needed, and the price was much better than others.ÚtilNo ayuda - B
Brandon Roost
02/09/2025
Siemens Disyuntor 3RV2032-4SA15Easy and quick as a flash!ÚtilNo ayuda - R
Ralph Graham
13/07/2025
Siemens Disyuntor 3RV2032-4SA15You're a packing expertÚtilNo ayuda - A
Alejandro
30/08/2024
Siemens Disyuntor 3RV2032-4SA15Great checkoutÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2032-4SA15¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2032-4SA15
$ 472 .75
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Siemens Disyuntor 3RV1031-4DA10
US$686.06
Fuji Disyuntor BC63E1CG-1P006
US$46.54
ABB Disyuntor SH201-B32
US$23.44
Siemens Disyuntor 3RV2021-1DA10
US$238.68
TRIAD Transformador F-213Z
US$73.93
Schneider Contactor LC1E0901F5N
US$43.85
Ferraz Shawmut Fusible A15QS6-2
US$38.46
TWIDEC Relé MT3-80DA
US$225.77
Duelund Resistor VSF 51R ±5% 10W
US$69.23
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
SUNON Ventilador KDE1204PKB2
US$17.69
CAMEL Batería 6-QWLZ-120(760)-K
US$310.40
CHELIC Cilindro de aire JDAD80*150
US$185.38
Autonics Interruptor S3PF-P3BBD
US$13.80
KOGANEI Válvula solenoide 200E1-SR
US$63.45
Lenze Brake Módulo BFK457-12
Contacta con nosotros
CHANTO Cilindro de aire JS32X20B
Contacta con nosotros
ABB Relé CR-M110DC4LG
US$17.69