Parámetro
| Tipo | 3RV1 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 0.32 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 0.22...0.32 A |
| Adecuado para motores de inducción con P | 0.09 kW |
| Liberaciones instantáneas de sobrecorriente | 4.2 A |
| Short-circuit breaking capacidad | 100 kA |
| Peso approx. | 0.303 kg |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S0 for motor protection CLASS 10 A-release0.22...0.32 A Short-circuit release 4.2 A
Screw terminal Standardswitching capacity with transverse auxiliary switch 1 NO+1 NC Phased-out product Successor
is SIRIUS 3RV2 Preferredsuccessor type is 3RV2011-0DA15
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
General technical data
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
protection class IP
on the front IP20 mechanical service life (switching cycles)
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typica 100 000
continuous current rated value 0.32 A
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.22 - 0.32
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating current
at AC-3 at 400 V rated value 0.32 A
operating power at AC-3
at 400 V rated value 90 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 2 A
at 230 V 0.5 A
operating current of auxiliary contacts at DC-13
at 24 V 1 A
at 60 V 0.15 A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 50022
height 97 mm width 45 mm depth 96 mm
Circuit breaker size S0 for motor protection CLASS 10 A-release0.22...0.32 A Short-circuit release 4.2 A
Screw terminal Standardswitching capacity with transverse auxiliary switch 1 NO+1 NC Phased-out product Successor
is SIRIUS 3RV2 Preferredsuccessor type is 3RV2011-0DA15
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
General technical data
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
protection class IP
on the front IP20 mechanical service life (switching cycles)
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typica 100 000
continuous current rated value 0.32 A
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.22 - 0.32
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating current
at AC-3 at 400 V rated value 0.32 A
operating power at AC-3
at 400 V rated value 90 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 2 A
at 230 V 0.5 A
operating current of auxiliary contacts at DC-13
at 24 V 1 A
at 60 V 0.15 A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 50022
height 97 mm width 45 mm depth 96 mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo cambiar mi dirección de correo electrónico asociada a mi cuenta?
Responder: Para cambiar la dirección de correo electrónico asociada a su cuenta, comuníquese con nuestro equipo de servicio al cliente y proporcióneles la información de verificación necesaria. Ellos le ayudarán a actualizar su dirección de correo electrónico.
- Consulta: ¿Puedo guardar artículos en mi carrito para comprarlos más tarde?
Responder: Sí, puede guardar artículos en su carrito para futuras compras. Al agregar artículos a su lista de deseos o guardarlos en su cuenta, podrá acceder fácilmente a ellos y comprarlos más tarde sin necesidad de buscarlos nuevamente.
- Consulta: ¿Cómo puedo ver la calificación promedio y las reseñas de los usuarios de un producto?
Responder: En la página de detalles del producto, puede ver la calificación promedio y las reseñas de los usuarios. Alentamos a los usuarios a compartir sus experiencias de compra y comentarios sobre los productos, para que pueda comprender mejor las opiniones y sugerencias de otros compradores.
Comentarios
- K
Kelly Hostetler
05/08/2025
Siemens Disyuntor 3RV1021-0DA15Exactly as I expected, with speedy delivery.ÚtilNo ayuda - M
Michael Hughes
19/04/2025
Siemens Disyuntor 3RV1021-0DA15I'm so glad you had express shipping available, thanks.ÚtilNo ayuda - S
Shawn Alexander
10/03/2025
Siemens Disyuntor 3RV1021-0DA15Same old reliable service, thanks.ÚtilNo ayuda - C
Clementina
30/08/2024
Siemens Disyuntor 3RV1021-0DA15Encontré lo que estaba buscandoÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV1021-0DA15¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV1021-0DA15
$ 355 .96
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Terasaki Disyuntor S400-NF
US$1142.31
Fuji Disyuntor CP31P-1M015
US$22.31
Terasaki Disyuntor ZS100-NF
US$326.92
Delixi Transformador JMB-25
US$32.50
Lovato Contactor 11BG0022D
US$86.25
Buss Fusible KTK-15
US$6.93
YLE Relé YL314-B-12V
US$17.31
Samsung Resistor RC1005J153CS
US$11.54
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
SKF Cojinete NUP 409 ECM/C3
US$76.92
ATMEL IC Integrated Circuit Chip AT89C51ED2-RDRUM
Contacta con nosotros
Honeywell Relé GRT-4C-AC12V
US$10.00
ULVAC Bomba de Vacío VS750A-A-02222-194231133
Contacta con nosotros
Copeland Compresor KATA-0100-TAD-801
Contacta con nosotros
BANDO Belt STS S5M-1225-25
US$88.46
SMC Válvula solenoide VNC214A-15A-5TZ
US$461.54
Sanyo Denki Ventilador 109P0424DZ6D4
US$13.50