Mejores selecciones
1/3
Siemens Disyuntor 3RV1011-1BA10
$ 324 .91
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Parámetro
| Tipo | 3RV1 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 2 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 1.4...2 A |
| Adecuado para motores de inducción con P | 0.75 kW |
| Liberaciones instantáneas de sobrecorriente | 26 A |
| Short-circuit breaking capacidad | 100 kA |
| Peso approx. | 0.28 kg |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S00 for motor protection, CLASS 10 A-release1.4...2 A
N-release 26 A Screw terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 1.4 - 2
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value 2A
operating current
at AC-3 at 400 V rated value 2 A
operating power at AC-3
at 230 V rated value 370 W
at 400 V rated value750 W
at 500 V rated value750 W
at 690 V rated value110 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 2 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 2 kA
response value current
of instantaneous short-circuit trip unit 26 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 2A
at 600 V rated value2 A
yielded mechanical performance hp
for single-phase AC motor
at 230 V rated value 0.125 hp
for three-phase AC motor
at 460/480 V rated value 0.75 hp
at 575/600 V rated value1 hp
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 35 A
at 500 V gL/gG 25 A
at 690 V gL/gG 25 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Circuit breaker size S00 for motor protection, CLASS 10 A-release1.4...2 A
N-release 26 A Screw terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 1.4 - 2
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value 2A
operating current
at AC-3 at 400 V rated value 2 A
operating power at AC-3
at 230 V rated value 370 W
at 400 V rated value750 W
at 500 V rated value750 W
at 690 V rated value110 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 2 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 2 kA
response value current
of instantaneous short-circuit trip unit 26 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 2A
at 600 V rated value2 A
yielded mechanical performance hp
for single-phase AC motor
at 230 V rated value 0.125 hp
for three-phase AC motor
at 460/480 V rated value 0.75 hp
at 575/600 V rated value1 hp
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 35 A
at 500 V gL/gG 25 A
at 690 V gL/gG 25 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo cambiar mi dirección de correo electrónico asociada a mi cuenta?
Responder: Para cambiar la dirección de correo electrónico asociada a su cuenta, comuníquese con nuestro equipo de servicio al cliente y proporcióneles la información de verificación necesaria. Ellos le ayudarán a actualizar su dirección de correo electrónico.
- Consulta: ¿Puedo guardar artículos en mi carrito para comprarlos más tarde?
Responder: Sí, puede guardar artículos en su carrito para futuras compras. Al agregar artículos a su lista de deseos o guardarlos en su cuenta, podrá acceder fácilmente a ellos y comprarlos más tarde sin necesidad de buscarlos nuevamente.
- Consulta: ¿Cómo puedo ver la calificación promedio y las reseñas de los usuarios de un producto?
Responder: En la página de detalles del producto, puede ver la calificación promedio y las reseñas de los usuarios. Alentamos a los usuarios a compartir sus experiencias de compra y comentarios sobre los productos, para que pueda comprender mejor las opiniones y sugerencias de otros compradores.
Comentarios
- H
Hector Lerma
13/06/2025
Siemens Disyuntor 3RV1011-1BA10Amazing shipping speed, thanks a lot.ÚtilNo ayuda - Z
ZUBEK MOTORS
07/05/2025
Siemens Disyuntor 3RV1011-1BA10Superb itemÚtilNo ayuda - T
Timothy Long
24/03/2025
Siemens Disyuntor 3RV1011-1BA10That's just what I needed to know!ÚtilNo ayuda - G
George Gurkin
04/01/2025
Siemens Disyuntor 3RV1011-1BA10Informative product overview.ÚtilNo ayuda - C
Craig Wiita
02/11/2024
Siemens Disyuntor 3RV1011-1BA10They had what I was searching for!ÚtilNo ayuda - E
Edgardo
22/02/2024
Siemens Disyuntor 3RV1011-1BA10He utilizado este disyuntor en varios proyectos y siempre ha funcionado a la perfección. La protección IP20 lo hace ideal para ambientes con polvo y humedad. El diseño es simple y funcional, y la instalación es muy fácil. Lo recomiendo para cualquier aplicación donde se necesite una protección confiable contra sobrecargas y cortocircuitos.ÚtilNo ayuda - C
Clara
01/02/2024
Siemens Disyuntor 3RV1011-1BA10Este disyuntor Siemens es una excelente opción para aplicaciones industriales. La curva de disparo B garantiza una protección rápida y precisa contra sobrecargas, mientras que la alta capacidad de corte de 10kA me da la seguridad de que mi equipo está protegido contra cortocircuitos severos. La calidad de construcción es excelente y el precio es muy competitivo.ÚtilNo ayuda - S
Santiago
03/01/2024
Siemens Disyuntor 3RV1011-1BA10¡Excelente disyuntor! La protección termomagnética de 10kA me da la tranquilidad de que mi circuito está protegido contra sobrecargas y cortocircuitos. La instalación en riel DIN fue muy sencilla y el tamaño compacto lo hace ideal para espacios reducidos. Lo recomiendo para cualquier aplicación residencial o comercial.ÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV1011-1BA10¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV1011-1BA10
$ 324 .91
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Siemens Disyuntor ED43B040
US$147.34
Mitsubishi Disyuntor AE1600-SW 3P
US$5371.09
Siemens Disyuntor 3RV1021-4AA15
US$427.24
Siemens Disyuntor 3RV1031-4GB10
US$1495.00
TRIAD Transformador F-361U
US$53.75
Siemens Contactor 3RT1064-2XF46-0LA2
US$4658.85
Ferraz Shawmut Fusible BS17GB69V45
US$38.46
OKITA Relé HFSS-1A-05WL
US$25.00
UniOhm Resistor 0603WAJ068JT5E
US$16.92
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Parker Válvula solenoide PHS520-M15
Contacta con nosotros
YUKEN Bomba de paletas HPV2MY-06-F-LAA-K1-20
Contacta con nosotros
Sumitomo Reduction Drive Caja de cambios Reductor de velocidad RNYM1-1420-B-40
Contacta con nosotros
Copeland Compresor 4DC3A2200-TSK-800
Contacta con nosotros
Baumer Codificador BFF 1G.24K360-L2-9
Contacta con nosotros
sauer danfoss Bomba de pistón 90L130DD5NN80P4C8FGBG
Contacta con nosotros
Danfoss Compresor 120U2317
Contacta con nosotros
Yeoshe Bomba de paletas IVP42-35-14-L-L-86AB-10
Contacta con nosotros