Siemens Disyuntor 3RV1011-0JA10
$ 323 .69
(5) 1
Comentarios
Cantidad
MOQ : 1
Pagos
Parámetro
Tipo | 3RV1 |
Tipo de disyuntor | Motor Protection Circuit Breakers |
Corriente nominal | 1 |
Número de polos | 1 pole |
Rango de ajuste para disparadores de sobrecarga térmica | 0.7...1 A |
Adecuado para motores de inducción con P | 0.25 kW |
Liberaciones instantáneas de sobrecorriente | 13 A |
Short-circuit breaking capacidad | 100 kA |
Peso approx. | 0.233 kg |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S00 for motor protection, CLASS 10 A-release0.7...1 A
N-release 13 A Screw terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.7 - 1
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value0.5 A
operating current
at AC-3 at 400 V rated value 0.5 A
operating power at AC-3
at 230 V rated value 60 W
at 400 V rated value160 W
at 500 V rated value180 W
at 690 V rated value250 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 13 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value1 A
at 600 V rated value1A
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 10 A
at 500 V gL/gG 10 A
at 690 V gL/gG 10 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Circuit breaker size S00 for motor protection, CLASS 10 A-release0.7...1 A
N-release 13 A Screw terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.7 - 1
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value0.5 A
operating current
at AC-3 at 400 V rated value 0.5 A
operating power at AC-3
at 230 V rated value 60 W
at 400 V rated value160 W
at 500 V rated value180 W
at 690 V rated value250 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 13 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value1 A
at 600 V rated value1A
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 10 A
at 500 V gL/gG 10 A
at 690 V gL/gG 10 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Las personas que compraron este artículo también vieron
ABB Disyuntor T2L160 DC TMD125 FFCL 3P
US$534.38
Mitsubishi Disyuntor NV125-SW 4P 50A
US$385.94
CHINT Transformador TDGC2-3
US$110.75
Shilin Contactor S-P15 220V
US$12.69
Littelfuse Fusible 0234003.MXEP
US$3.45
TYCO Relé OJ-SH-105LM
US$1.15
Siemens Resistor 6ES7972-0BB12-0XA0
US$113.08
Los clientes ven con frecuencia
Carel Válvula de expansión E6VB2ASV00
US$839.00
Mitsubishi Compresor RE277NRAMT
US$389.00
Togami Contactor CLK-25J3
US$79.00
Schneider Sensor XS8C4A1DPG13
US$401.15
IFM Sensor OIH582
US$320.46
SMC Válvula solenoide SY3120-5G-M5
US$68.98
Panasonic Relé JW1FSN-DC24V
US$10.24
Publicaciones relacionadas recientes
-
02/17/2024
Método de cableado del relé PTC de nevera
El relé PTC (coeficiente de temperatura positivo) está conectado directamente en serie con el devanado secundario (devanado de arranque) y en paralelo con el devanado principal del motor.
-
07/29/2023
Compresor Scroll Vs. Compresor rotativo para CA
El compresor scrollue inventado en 1905 por el francés Copeland. Creó la compañía Copeland en los Estados Unidos, donde se utilizan principalmente acondicionadores de aire de agua
-
05/19/2022
17 fabricantes de compresores centrífugos, en el mundo. ¿cuántos conoce?
En la última década, en un contexto de globalización económica y feroz competencia, la industria de fabricación de compresores centrífugos también ha experimentado continuas fusiones, adquisiciones y reorganizaciones.
-
01/07/2024
¿Por qué vibra el servomotor?
¿En qué casos vibrará un servomotor? ¿Qué pasa si el servomotor vibra? ¿Cómo podemos solucionar los problemas causados por la vibración? Este artículo explicará varias razones para esto.
-
08/08/2022
Motor de inducción de jaula de ardilla frente a motor de inducción de rotor bobinado: Estructura del rotor, ventajas e inconvenientes
El motor de inducción trifásico consta de dos partes básicas: el estator y el rotor. El estator es la parte fija del motor y se utiliza para generar un campo magnético giratorio.
-
12/05/2023
Principios y diferencias de los transmisores de 2, 3 y 4 hilos
Los transmisores de 2, 3 y 4 hilos se refieren a transmisores cuyas salidas son señales analógicas de corriente CC.
-
05/11/2022
Reparación de averías en servoaccionamientos Ultra3000
Hemos enumerado las fallas comunes y los métodos de reparación de los servovariadores Ultra3000; si necesita reemplazar el equipo, le brindamos Servoaccionamiento Allen Bradley Rockwell.
-
08/08/2023
Método de cálculo del peso por metro de tubo de cobre para aire acondicionado
Método de cálculo del peso por metro de tubería de cobre para aire acondicionado.
-
11/18/2023
Transmisores Rosemount Series 1151, 2088, 2051, 3051CA, 3051S y sus diferencias
El transmisor de presión Rosemount es un tipo de transmisor de presión general. Está fabricado según la ley de inducción electromagnética y la norma JB/T9248-1999.
-
03/10/2024
Todo lo que debe saber sobre el embrague magnético del compresor de CA del coche
Este artículo presenta los componentes del embrague magnético del compresor y su principio de funcionamiento, así como varios parámetros importantes. Además, también le brindamos algunas experiencias sobre cómo lidiar con la quema de los embragues del compresor del aire acondicionado.