Mejores selecciones
1/1
Dwyer Caudalímetro UFC-122
No hay precio en este momento, puede solicitar una cotización
Service:Homogeneous liquids that do not contain more than 3% of air bubbles or particulate and capable of ultrasonic wave propagation.
Inputs:TNC cable from sensors.
Range:0.33 to 33 ft/s (0.1 to 10 m/s) .
Display:240 x 64 pixel graphic display, high contrast black on white with backlight. Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5" W x 1.3" H (5 x 33.02 mm).
Accuracy:±0.5 to ±2% of flow reading of flow rate > 0.03 ft/s (0.01 m/s) and pipe OD > 3.0 in (75 mm); ±3% of flow reading for flow rate > 0.03 ft/s (0.01 m/s) and pipe OD 0.5 to 3 in (13 to 75 mm); ±6% of flow reading for flow rate < 0.03 ft/s (0.01 m/s).
Power Requirements:86 to 264 VAC (50 to 60 Hz) or 24 VAC/VDC (1 A max.).
Power Consumption:10.5 W.
Temperature Limits:Transducer: -4 to 275°F (-20 to 135°C); Controller: -4 to 122°F (-20 to 50°C).
Outputs:Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 O max; Alarm: 2 opto-isolated MOSFET NO relays, 48 V at 500 mA, maximum 200 Hz; Pulsed: 1 opto-isolated MOSFET relay, 48 V at 500 mA, 1 to 250 pps; Pulse width: 2 to 500 ms (selectable).
Serial Communications:USB.Materials:Plastic ABS and aluminum.
Repeatability:±0.5% of measured value or 0.03 ft/s (0.01 m/s).
Electrical Connections:Removeable screw in type terminal block.
Mounting:Wall mounted using 3 type M4 screws.
Turbidity:<3% by volume of particulate content.
Permissible Air Content:<3% by volume.
Response Time:<500 ms.
Weight:Unit not including accessories: 2.80 lb (1.26 kg); Unit including accessories: 9.92 lb (4.5 kg).
Inputs:TNC cable from sensors.
Range:0.33 to 33 ft/s (0.1 to 10 m/s) .
Display:240 x 64 pixel graphic display, high contrast black on white with backlight. Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5" W x 1.3" H (5 x 33.02 mm).
Accuracy:±0.5 to ±2% of flow reading of flow rate > 0.03 ft/s (0.01 m/s) and pipe OD > 3.0 in (75 mm); ±3% of flow reading for flow rate > 0.03 ft/s (0.01 m/s) and pipe OD 0.5 to 3 in (13 to 75 mm); ±6% of flow reading for flow rate < 0.03 ft/s (0.01 m/s).
Power Requirements:86 to 264 VAC (50 to 60 Hz) or 24 VAC/VDC (1 A max.).
Power Consumption:10.5 W.
Temperature Limits:Transducer: -4 to 275°F (-20 to 135°C); Controller: -4 to 122°F (-20 to 50°C).
Outputs:Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 O max; Alarm: 2 opto-isolated MOSFET NO relays, 48 V at 500 mA, maximum 200 Hz; Pulsed: 1 opto-isolated MOSFET relay, 48 V at 500 mA, 1 to 250 pps; Pulse width: 2 to 500 ms (selectable).
Serial Communications:USB.Materials:Plastic ABS and aluminum.
Repeatability:±0.5% of measured value or 0.03 ft/s (0.01 m/s).
Electrical Connections:Removeable screw in type terminal block.
Mounting:Wall mounted using 3 type M4 screws.
Turbidity:<3% by volume of particulate content.
Permissible Air Content:<3% by volume.
Response Time:<500 ms.
Weight:Unit not including accessories: 2.80 lb (1.26 kg); Unit including accessories: 9.92 lb (4.5 kg).
Hacer preguntas
(0/1,200)
- Consulta: ¿Qué debo hacer si recibo un artículo dañado o defectuoso?
Responder: Si recibe un artículo dañado o defectuoso, comuníquese con nuestro equipo de atención al cliente de inmediato. Bríndeles los detalles necesarios y, si es posible, incluya fotografías de los daños. Le ayudaremos a resolver el problema ofreciéndole un reemplazo, un reembolso o una solución adecuada.
- Consulta: ¿Cómo puedo ver el estado y el historial de mis pedidos?
Responder: Puede iniciar sesión en su cuenta, acceder a la página de pedidos y ver el estado y el historial de sus pedidos. Actualizaremos el estado del pedido con prontitud y proporcionaremos información detallada del pedido para su comodidad al realizar consultas y seguimiento.
- Consulta: ¿Qué debo hacer si recibo el artículo incorrecto?
Responder: Si recibe el artículo incorrecto, comuníquese con nuestro equipo de servicio al cliente de inmediato. Bríndeles los detalles del pedido y una descripción del artículo incorrecto recibido. Rectificaremos el problema organizando una devolución y enviándole el artículo correcto.
Comentarios
- U
Usuario anónimo
25/11/2022
Dwyer Caudalímetro UFC-122¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Dwyer Caudalímetro UFC-122
No hay precio en este momento, puede solicitar una cotización
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
TRANSTECNO Motor Eléctrico MS80M1-4
US$258.46
Copeland Compresor 6SLW-250E-AWM
US$4225.35
CKD Válvula solenoide M4HA110-M5-8-3
Contacta con nosotros
MUNDORF Condensador 600V 10UF
US$200.00
PARKER Filtro 1303 20QE B MP
US$519.23
SMC Válvula solenoide SY7200-5UD1
US$144.90
Siemens Sensor 3RG4014-3AB00-2AA1
US$115.00
Bristol Compresor H89B183ABHK
Contacta con nosotros