Mejores selecciones
1/1
Chint Disyuntor NXMLE-250S/4300A
No hay precio en este momento, puede solicitar una cotización
¡El Chint Circuit Breaker es de alta calidad!
¡El rated working voltage Ue(V), AC 50/60Hz 230/240,400/415
Residual current operating characteristics AC type, A type
¡El rated residual operating current IΔn (ma) (2p, 3P+N, 4P) is not adjustable in single gear, and is of non-delay type 30/50/100/200/300/500
(2P, 3P+N, 4P) single gear is not adjustable, and the delay type is 50/100/200/300/500
¡El rated residual inoperative current IΔno (ma) is 0.5IΔn.
Maximum breaking time (s) of non-delay 5IΔn ≤ 0.04
¡El main function of residual current operated circuit breaker series is to provide indirect contact
protection for fatal personal electric shock, and to provide protection for electrical fire caused by
ground fault current, such as insulation damage. It also provides protection for overload, short
circuit and undervoltage of the line, and can also be used for infrequent switching of the line.
Grade of shell frame: 125A, 160A, 250A, 400A, 630A, 800A
¡El rated working voltage Ue(AC): AC 230V/240V(1P+N, 2P),
AC 400V/415V(3P, 3P+N,4P)
Code of breaking capacity: s and h
Number of poles: 1P+N, 2P, 3P, 3P+N, 4P 1P+N, 2P is only applicable to shell products of 250A and below)
Installation mode: fixed type and plug-in type
NXMLE-125 H P/3 300 2
NXMLE: residual current operated circuit breaker
125: current level code of shell frame 125A 160A 250A 400A 630A 800A
H: breaking capacity code s: (ac230v/ac240v): 36ka (ac400v/ac415v: 25ka
H:(AC230V/AC240V):50kA(AC400V/AC415V):36kA
P: operation mode code No code handle direct operation P electric operation Z: rotating handle operation
3: Pole number code 1P+N 2P 3P 3P+N 4P
300: Trip Method and Internal Attachment Code
2. Use code No code: for distribution protection 2: for motor protection 3: for generator protection
¡El rated working voltage Ue(V), AC 50/60Hz 230/240,400/415
Residual current operating characteristics AC type, A type
¡El rated residual operating current IΔn (ma) (2p, 3P+N, 4P) is not adjustable in single gear, and is of non-delay type 30/50/100/200/300/500
(2P, 3P+N, 4P) single gear is not adjustable, and the delay type is 50/100/200/300/500
¡El rated residual inoperative current IΔno (ma) is 0.5IΔn.
Maximum breaking time (s) of non-delay 5IΔn ≤ 0.04
¡El main function of residual current operated circuit breaker series is to provide indirect contact
protection for fatal personal electric shock, and to provide protection for electrical fire caused by
ground fault current, such as insulation damage. It also provides protection for overload, short
circuit and undervoltage of the line, and can also be used for infrequent switching of the line.
Grade of shell frame: 125A, 160A, 250A, 400A, 630A, 800A
¡El rated working voltage Ue(AC): AC 230V/240V(1P+N, 2P),
AC 400V/415V(3P, 3P+N,4P)
Code of breaking capacity: s and h
Number of poles: 1P+N, 2P, 3P, 3P+N, 4P 1P+N, 2P is only applicable to shell products of 250A and below)
Installation mode: fixed type and plug-in type
NXMLE-125 H P/3 300 2
NXMLE: residual current operated circuit breaker
125: current level code of shell frame 125A 160A 250A 400A 630A 800A
H: breaking capacity code s: (ac230v/ac240v): 36ka (ac400v/ac415v: 25ka
H:(AC230V/AC240V):50kA(AC400V/AC415V):36kA
P: operation mode code No code handle direct operation P electric operation Z: rotating handle operation
3: Pole number code 1P+N 2P 3P 3P+N 4P
300: Trip Method and Internal Attachment Code
2. Use code No code: for distribution protection 2: for motor protection 3: for generator protection
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo consultar la fecha de producción o fecha de vencimiento de un producto?
Responder: Para comprobar la fecha de producción o la fecha de caducidad de un producto, puede consultar el embalaje o las etiquetas del producto. Proporcionamos información clara y precisa sobre la fecha de fabricación y la fecha de vencimiento, lo que le permite tomar decisiones de compra informadas. Si necesita más ayuda, nuestro equipo de atención al cliente siempre está listo para ayudar.
- Consulta: ¿El producto tiene garantía de calidad?
Responder: ¡Absolutamente! Estamos orgullosos de ofrecer productos de alta calidad. Cada producto se somete a rigurosos controles de calidad para garantizar la excelencia y la satisfacción del cliente. Respaldamos la calidad de nuestros productos.
- Consulta: ¿Cómo puedo enviar comentarios o reseñar un producto?
Responder: Puede proporcionar comentarios o reseñar un producto accediendo a la página del producto y haciendo clic en la opción "Escribir una reseña" o "Dejar comentarios". Comparta su experiencia y opiniones para ayudar a otros compradores a tomar decisiones informadas.
Comentarios
- U
Usuario anónimo
25/11/2022
Chint Disyuntor NXMLE-250S/4300A¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Chint Disyuntor NXMLE-250S/4300A
No hay precio en este momento, puede solicitar una cotización
Las personas que compraron este artículo también vieron
ABB Disyuntor T2L160 DC TMD125 FFCL 4P
US$799.61
TRIAD Transformador FS10-1200
US$38.00
Siemens Contactor 3TF6833-8DF4
US$24129.62
Littelfuse Fusible FLNR-5
US$13.80
HONGFA Relé HFD3-I-5-L1SR
US$2.31
UniOhm Resistor 1206W4J0513T5E
US$10.96
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Toshiba Compresor PH410M3CS-4MUL
US$352.11
Emerson Alco Válvula de expansión TX6-M05 801 566
Contacta con nosotros
ADDA Ventilador AD1212LB-F91GP
US$16.15
NSK Cojinete NU 2309 ET
US$107.69
Copeland Compresor 4DJ1-3000-TSE-201
Contacta con nosotros
Schneider Disyuntor A9D65240
US$375.00
AirTAC Cilindro de aire MAC40X90SCA
US$49.23