Mejores selecciones
1/1
Chint Disyuntor NXM-125S/4300B
No hay precio en este momento, puede solicitar una cotización
¡El Chint Circuit Breaker es de alta calidad!
¡El rated working voltage Ue(V), AC 50/60Hz 230/240,400/415,500
¡El breaking capacity code is S 2P 3P 4P H 3/4P
¡El rated limit short circuit breaking capacity is Icu(kA)AC230/240V 36
AC400/415V 25
AC500V -
AC690V -
¡El rated running short circuit breaking capacity Ics(kA) AC230/240V 50
AC400/415V 36
AC500V - 15
AC690V -
¡El molded case circuit breaker can protect the lines and equipment in distribution lines when overload,
short circuit and undervoltage occur, and can also provide overload, short circuit and undervoltage
protection for infrequent starting of motors.
Grade of shell frame
NXM series molded case circuit breakers: 63A, 125A, 160A, 250A, 400A, 630A, 800A,
1000A、1250A、1600A
¡El rated working voltage UE (AC): 230v/240v, 400V/415V, 500V, 690V(63A,
125A shell frame has no 690V, and 1250A/1600A shell frame has no 500V)
Code of breaking capacity: s and h
Number of poles: 2P, 3P, 4P(2P is only applicable to shell products of 250A and below)
Release types: electromagnetic, thermomagnetic and thermally adjustable magnetic fixed
Installation mode: fixed type and plug-in type
NXM-160-S P /4 300
NXM: Product code NXM series molded case circuit breaker
160: current grade code of shell frame 63a 125a 160a 250a 400a 630a 800a 1000a 1250a 1600a
S: breaking capacity code s 25kah: 50ka (63a 125a) s 36kah: 50ka (160a 250a)
S 50kA H:70kA(400A 630A 800A 1000A 1250A 1600A)
P: operation mode code No code handle direct operation P electric operation Z: rotating handle operation
4. Number of poles Code 2: Two poles 3: Three poles 4: Four poles
¡El first digit of 300 release mode and internal accessory code represents release mode 2: electromagnetic type
3: Thermomagnetic
(¡El function of thermal overload alarm without tripping can only be selected 3) ¡El second and third digits
are internal accessory codes
¡El rated working voltage Ue(V), AC 50/60Hz 230/240,400/415,500
¡El breaking capacity code is S 2P 3P 4P H 3/4P
¡El rated limit short circuit breaking capacity is Icu(kA)AC230/240V 36
AC400/415V 25
AC500V -
AC690V -
¡El rated running short circuit breaking capacity Ics(kA) AC230/240V 50
AC400/415V 36
AC500V - 15
AC690V -
¡El molded case circuit breaker can protect the lines and equipment in distribution lines when overload,
short circuit and undervoltage occur, and can also provide overload, short circuit and undervoltage
protection for infrequent starting of motors.
Grade of shell frame
NXM series molded case circuit breakers: 63A, 125A, 160A, 250A, 400A, 630A, 800A,
1000A、1250A、1600A
¡El rated working voltage UE (AC): 230v/240v, 400V/415V, 500V, 690V(63A,
125A shell frame has no 690V, and 1250A/1600A shell frame has no 500V)
Code of breaking capacity: s and h
Number of poles: 2P, 3P, 4P(2P is only applicable to shell products of 250A and below)
Release types: electromagnetic, thermomagnetic and thermally adjustable magnetic fixed
Installation mode: fixed type and plug-in type
NXM-160-S P /4 300
NXM: Product code NXM series molded case circuit breaker
160: current grade code of shell frame 63a 125a 160a 250a 400a 630a 800a 1000a 1250a 1600a
S: breaking capacity code s 25kah: 50ka (63a 125a) s 36kah: 50ka (160a 250a)
S 50kA H:70kA(400A 630A 800A 1000A 1250A 1600A)
P: operation mode code No code handle direct operation P electric operation Z: rotating handle operation
4. Number of poles Code 2: Two poles 3: Three poles 4: Four poles
¡El first digit of 300 release mode and internal accessory code represents release mode 2: electromagnetic type
3: Thermomagnetic
(¡El function of thermal overload alarm without tripping can only be selected 3) ¡El second and third digits
are internal accessory codes
Hacer preguntas
(0/1,200)
- Consulta: Cuanto tiempo tarda el envio?
Responder: El tiempo de envío depende del método de envío que elijas y del destino. Los tiempos de entrega estimados generalmente se proporcionan durante el proceso de pago.
- Consulta: ¿Cómo puedo verificar la certificación de seguridad o la información de cumplimiento de un producto?
Responder: Para productos que requieren certificación o cumplimiento de seguridad, proporcionamos información relevante en la página de detalles del producto. Puede consultar las etiquetas de certificación o descripciones para asegurarse de que el producto cumpla con los estándares y regulaciones pertinentes.
- Consulta: ¿Cómo me registro como miembro y qué privilegios tienen los miembros?
Responder: Registrarse como miembro es muy simple; solo necesita proporcionar cierta información básica. Los miembros pueden disfrutar de actividades promocionales exclusivas, puntos de recompensa, pago rápido y privilegios exclusivos de servicio al cliente.
Comentarios
- U
Usuario anónimo
25/11/2022
Chint Disyuntor NXM-125S/4300B¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Chint Disyuntor NXM-125S/4300B
No hay precio en este momento, puede solicitar una cotización
Las personas que compraron este artículo también vieron
ABB Disyuntor 10113660
US$42.97
EATON Transformador DTZ0.16
US$277.18
Lovato Contactor BF6500E
US$448.50
Siemens Fusible 3NA3803-2C
US$319.50
CRYDOM Relé RPC48125
US$211.54
UniOhm Resistor 25121WF1503T4E
US$184.62
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Schneider Sensor XS212BLPAL10
US$133.85
Haier Aire acondicionado KFR-26GW-01NJC23A
US$1153.46
Delta Servo Motor ECM-B3M-EP1310P71
Contacta con nosotros
PIZZATO Interruptor FR 555-M1
US$576.92
Danfoss Válvula de expansión TGE 067N5241
Contacta con nosotros
Nachi Bomba de engranajes IPH-22A-5-5-TT-11
Contacta con nosotros