Chint Disyuntor DZ47LE-32 D20 2P
No hay precio en este momento, puede solicitar una cotización
¡El Chint Circuit Breaker es de alta calidad!
DZ47LE series residual current operated circuit breaker is suitable for AC 50Hz,
rated voltage unipolar two-wire, bipolar 230V, three-pole, three-pole four-wire,
four-pole 400V, rated current up to 60A, when personal electric shock or power
grid leakage,
When the leakage current exceeds the specified value, the residual current operated
circuit breaker can quickly cut off the fault power supply in a very short time,
protect the safety of people and electrical equipment, and can also be used for
overload and short circuit protection of lines, and make and break electrical
devices and lighting lines infrequently under normal circumstances, especially
suitable for industrial and commercial lighting distribution systems.
¡El rated short-circuit breaking capacity is 6000a (C6 ~ C40); 4500A(C50、C60、D6~D60
¡El rated residual on and off capacity is 500a (INM = 32a); 630A(Inm=63A)
¡El ambient temperature is -5℃~40℃, and the average temperature within 24h does not exceed 35℃.
Elevation: ≤2000m.
Installation conditions: the external magnetic field of the installation site should not exceed 5
times of the geomagnetic field in any direction;
¡El residual current operated circuit breaker shall be installed vertically, and the handle shall
be turned on upwards.
There should be no significant impact and vibration at the installation site.
Connection mode: use screws to press the connection.
Ambient air temperature:
¡El maximum temperature of ambient air is 40℃, the minimum temperature is not lower than -5℃,
and the average temperature within 24h is not more than +35℃
DZ47LE series residual current operated circuit breaker is suitable for AC 50Hz,
rated voltage unipolar two-wire, bipolar 230V, three-pole, three-pole four-wire,
four-pole 400V, rated current up to 60A, when personal electric shock or power
grid leakage,
When the leakage current exceeds the specified value, the residual current operated
circuit breaker can quickly cut off the fault power supply in a very short time,
protect the safety of people and electrical equipment, and can also be used for
overload and short circuit protection of lines, and make and break electrical
devices and lighting lines infrequently under normal circumstances, especially
suitable for industrial and commercial lighting distribution systems.
¡El rated short-circuit breaking capacity is 6000a (C6 ~ C40); 4500A(C50、C60、D6~D60
¡El rated residual on and off capacity is 500a (INM = 32a); 630A(Inm=63A)
¡El ambient temperature is -5℃~40℃, and the average temperature within 24h does not exceed 35℃.
Elevation: ≤2000m.
Installation conditions: the external magnetic field of the installation site should not exceed 5
times of the geomagnetic field in any direction;
¡El residual current operated circuit breaker shall be installed vertically, and the handle shall
be turned on upwards.
There should be no significant impact and vibration at the installation site.
Connection mode: use screws to press the connection.
Ambient air temperature:
¡El maximum temperature of ambient air is 40℃, the minimum temperature is not lower than -5℃,
and the average temperature within 24h is not more than +35℃
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo cambiar mi dirección de correo electrónico asociada a mi cuenta?
Responder: Para cambiar la dirección de correo electrónico asociada a su cuenta, comuníquese con nuestro equipo de servicio al cliente y proporcióneles la información de verificación necesaria. Ellos le ayudarán a actualizar su dirección de correo electrónico.
- Consulta: ¿Puedo guardar artículos en mi carrito para comprarlos más tarde?
Responder: Sí, puede guardar artículos en su carrito para futuras compras. Al agregar artículos a su lista de deseos o guardarlos en su cuenta, podrá acceder fácilmente a ellos y comprarlos más tarde sin necesidad de buscarlos nuevamente.
- Consulta: ¿Cómo puedo ver la calificación promedio y las reseñas de los usuarios de un producto?
Responder: En la página de detalles del producto, puede ver la calificación promedio y las reseñas de los usuarios. Alentamos a los usuarios a compartir sus experiencias de compra y comentarios sobre los productos, para que pueda comprender mejor las opiniones y sugerencias de otros compradores.
Comentarios
- U
Usuario anónimo
25/11/2022
Chint Disyuntor DZ47LE-32 D20 2P¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Chint Disyuntor DZ47LE-32 D20 2P
No hay precio en este momento, puede solicitar una cotización
Las personas que compraron este artículo también vieron
Fuji Disyuntor CP30FM-2P005
US$81.92
TRIAD Transformador FS120-02
US$29.33
Schurter Fusible 0001.1037
US$4.03
OEG Relé OJE-SH-124HM
US$1.15
UniOhm Resistor 1206W4J0201T5E
US$17.31
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
HONGFA Relé HF33F-005-HS3
US$42.44
Omron PLC CS1W-MCH71
US$5993.78
ASCO Válvula solenoide 153SA425K
Contacta con nosotros
Yaskawa Servo Motor SGMGV-03A3A2C
US$384.62
ULVAC Bomba de Vacío PMB100DT-MF2A2F1XXB1
Contacta con nosotros
LEOCH Batería DJM1265S
US$151.93
LEEMIN Filtro TZX2-630-5
US$132.69
Lenze VFD Frequency Converter EVS9329-ES
US$5480.00