Circuit breaker 4 a tripper 2.8 ... 4 A A n tripper 52 A, used for motor protection, etc
Class 10, threaded connection, standard switch capacity, with lateral auxiliary switch 1 NO+1 NC
Product brand name SIRIUS
Product Name Circuit Breaker
Product specifications are used for motor protection
Product type name 3RV6
Comprehensive technical data
Structural dimension S00 of circuit breaker
¡El loss power W totals 6 W typically
¡El measured value is 690 V at AC when the pollution degree of isolation voltage is 3
¡El measured value of impulse voltage resistance is 6 kV
Protection level IP
IP20 on the front
connection terminal IP20
dent resistance
comply with IEC 60068-2-27 25g/11 ms
environmental conditions
¡El installation height is higher than the horizontal plane
the maximum value is 2 000 m.
Ambient temperature
-20 ...+60 c during operation
-50 ...+80 C during transportation
Relative air humidity during operation 10 ... 95%
main circuit
¡El number of poles is used for the main circuit 3
Settable current action value 2.8 ... 4 A of overload tripping of current control
Working voltage
the measured value is 690 V
the maximum measured value is 690 V at AC-3
¡El measured working frequency is 50 ... 60 Hz
¡El measured working current is 4 a.
Working current
AC-3 AC-3
the measured value is 4 A at 400v
Switching frequency
the maximum value at AC-3 is 15 1/H.
auxiliary circuit
¡El structure of the auxiliary switch is horizontally placed
Protection and monitoring functions
Trip level CLASS 10
Over-current release specification heat
Working short circuit current (Ics) breaking capacity AC
the measured value at 400v is 100 kA
Breaking capacity of limit short circuit current (Icu)
the measured value at 400 V at AC is 100 kA
Current action value
52 A of short circuit release without delay
Protection device to prevent short circuit from causing damage to switching device.
Product function short circuit protection yes
Specification of short circuit release magnetic
Mounting/fixing/outline dimensions
¡El loading position is arbitrary
Fastening type: screw fastening and snap fastening on 35mm mounting rail according to DIN EN 60715
Height 97 mm
Width 45 mm
Depth 96 mm
Circuit breaker 4 a tripper 2.8 ... 4 A A n tripper 52 A, used for motor protection, etc
Class 10, threaded connection, standard switch capacity, with lateral auxiliary switch 1 NO+1 NC
Product brand name SIRIUS
Product Name Circuit Breaker
Product specifications are used for motor protection
Product type name 3RV6
Comprehensive technical data
Structural dimension S00 of circuit breaker
¡El loss power W totals 6 W typically
¡El measured value is 690 V at AC when the pollution degree of isolation voltage is 3
¡El measured value of impulse voltage resistance is 6 kV
Protection level IP
IP20 on the front
connection terminal IP20
dent resistance
comply with IEC 60068-2-27 25g/11 ms
environmental conditions
¡El installation height is higher than the horizontal plane
the maximum value is 2 000 m.
Ambient temperature
-20 ...+60 c during operation
-50 ...+80 C during transportation
Relative air humidity during operation 10 ... 95%
main circuit
¡El number of poles is used for the main circuit 3
Settable current action value 2.8 ... 4 A of overload tripping of current control
Working voltage
the measured value is 690 V
the maximum measured value is 690 V at AC-3
¡El measured working frequency is 50 ... 60 Hz
¡El measured working current is 4 a.
Working current
AC-3 AC-3
the measured value is 4 A at 400v
Switching frequency
the maximum value at AC-3 is 15 1/H.
auxiliary circuit
¡El structure of the auxiliary switch is horizontally placed
Protection and monitoring functions
Trip level CLASS 10
Over-current release specification heat
Working short circuit current (Ics) breaking capacity AC
the measured value at 400v is 100 kA
Breaking capacity of limit short circuit current (Icu)
the measured value at 400 V at AC is 100 kA
Current action value
52 A of short circuit release without delay
Protection device to prevent short circuit from causing damage to switching device.
Product function short circuit protection yes
Specification of short circuit release magnetic
Mounting/fixing/outline dimensions
¡El loading position is arbitrary
Fastening type: screw fastening and snap fastening on 35mm mounting rail according to DIN EN 60715
Height 97 mm
Width 45 mm
Depth 96 mm
Las personas que compraron este artículo también vieron
Eaton Moeller Disyuntor LZMB1-A20
US$147.06
Eaton Moeller Disyuntor E6X-10/3/C
US$29.41
Siemens Disyuntor 3WN6361-0GV58-0AK1
US$13048.83
Siemens Disyuntor 5SY6101-7
US$31.25
TRIAD Transformador TCT50-06E07K
US$67.40
Lovato Contactor BG0601D
US$788.46
Nais Relé DS2E-ML2-DC9V
US$3.85
IRC Resistor 20190905 1W 80.4R
US$19.23
Los clientes ven con frecuencia
Carel Válvula de expansión E6VB2ASV00
US$839.00
Mitsubishi Compresor RE277NRAMT
US$389.00
Togami Contactor CLK-25J3
US$79.00
EACO Condensador STH-600-3.3-37
US$3.65
ORION Ventilador OD172SAP-24HB
US$205.44
Festo Cilindro de aire ADN-80-25-A-P-A
US$231.77
Bristol Compresor H23A503DBEA
US$807.69
Publicaciones relacionadas recientes
-
12/05/2023
Principios y diferencias de los transmisores de 2, 3 y 4 hilos
Los transmisores de 2, 3 y 4 hilos se refieren a transmisores cuyas salidas son señales analógicas de corriente CC.
-
11/18/2023
Transmisores Rosemount Series 1151, 2088, 2051, 3051CA, 3051S y sus diferencias
El transmisor de presión Rosemount es un tipo de transmisor de presión general. Está fabricado según la ley de inducción electromagnética y la norma JB/T9248-1999.
-
02/18/2024
Método de cableado del relé PTC de nevera
El relé PTC (coeficiente de temperatura positivo) está conectado directamente en serie con el devanado secundario (devanado de arranque) y en paralelo con el devanado principal del motor.
-
07/29/2023
Compresor Scroll Vs. Compresor rotativo para CA
El compresor scrollue inventado en 1905 por el francés Copeland. Creó la compañía Copeland en los Estados Unidos, donde se utilizan principalmente acondicionadores de aire de agua
-
05/12/2022
Reparación de averías en servoaccionamientos Ultra3000
Hemos enumerado las fallas comunes y los métodos de reparación de los servovariadores Ultra3000; si necesita reemplazar el equipo, le brindamos Servoaccionamiento Allen Bradley Rockwell.
-
06/27/2023
Principio de funcionamiento del compresor frigorífico, esquema eléctrico, estructura
El componente principal del refrigerador es el compresor. Si un frigorífico no está equipado con un compresor de buena calidad y tecnología no puede ser un buen frigorífico.
-
03/10/2024
Todo lo que debe saber sobre el embrague magnético del compresor de CA del coche
Este artículo presenta los componentes del embrague magnético del compresor y su principio de funcionamiento, así como varios parámetros importantes. Además, también le brindamos algunas experiencias sobre cómo lidiar con la quema de los embragues del compresor del aire acondicionado.
-
01/08/2024
¿Por qué vibra el servomotor?
¿En qué casos vibrará un servomotor? ¿Qué pasa si el servomotor vibra? ¿Cómo podemos solucionar los problemas causados por la vibración? Este artículo explicará varias razones para esto.
-
08/04/2023
Aire acondicionado Mitsubishi vs Panasonic
El verano es tan difícil de pasar que las personas sin aire acondicionado son como peces fuera del agua. Es fundamental elegir un buen aire acondicionado.
-
08/08/2023
Método de cálculo del peso por metro de tubo de cobre para aire acondicionado
Método de cálculo del peso por metro de tubería de cobre para aire acondicionado.