Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 40 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 28...40 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S3 for motor protection, Class 20 A-release
28...40 A N-release 520 A screw terminal Increased switching
capacity 100 kA
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S3
size of contactor can be combined company-specific S3
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 23?W
at AC in hot operating state per pole 7.7?W
insulation voltage with degree of pollution 3 at AC
rated value
1?000?V
surge voltage resistance rated value 8?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 25?000
of auxiliary contacts typical 25?000
electrical endurance (switching cycles)
typical 25?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
28?...?40?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 40?A
operating current
at AC-3
at 400 V rated value 40?A
operating power
at AC-3
at 230 V rated value 11?000?W
at 400 V rated value 18?500?W
at 500 V rated value 22?000?W
at 690 V rated value 37?000?W
operating frequency
at AC-3 maximum 15?1/h
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class Class 20
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 9?kA
at 690 V rated value 6?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 18?kA
at AC at 690 V rated value 12?kA
response value current
of instantaneous short-circuit trip unit 520?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 40?A
at 600 V rated value 40?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 3?hp
at 230 V rated value 7.5?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 15?hp
at 460/480 V rated value 30?hp
at 575/600 V rated value 40?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 165?mm
width 70?mm
depth 176?mm
Circuit breaker size S3 for motor protection, Class 20 A-release
28...40 A N-release 520 A screw terminal Increased switching
capacity 100 kA
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S3
size of contactor can be combined company-specific S3
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 23?W
at AC in hot operating state per pole 7.7?W
insulation voltage with degree of pollution 3 at AC
rated value
1?000?V
surge voltage resistance rated value 8?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 25?000
of auxiliary contacts typical 25?000
electrical endurance (switching cycles)
typical 25?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
28?...?40?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 40?A
operating current
at AC-3
at 400 V rated value 40?A
operating power
at AC-3
at 230 V rated value 11?000?W
at 400 V rated value 18?500?W
at 500 V rated value 22?000?W
at 690 V rated value 37?000?W
operating frequency
at AC-3 maximum 15?1/h
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class Class 20
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 9?kA
at 690 V rated value 6?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 18?kA
at AC at 690 V rated value 12?kA
response value current
of instantaneous short-circuit trip unit 520?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 40?A
at 600 V rated value 40?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 3?hp
at 230 V rated value 7.5?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 15?hp
at 460/480 V rated value 30?hp
at 575/600 V rated value 40?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 165?mm
width 70?mm
depth 176?mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo cambiar mi dirección de correo electrónico asociada a mi cuenta?
Responder: Para cambiar la dirección de correo electrónico asociada a su cuenta, comuníquese con nuestro equipo de servicio al cliente y proporcióneles la información de verificación necesaria. Ellos le ayudarán a actualizar su dirección de correo electrónico.
- Consulta: ¿Puedo guardar artículos en mi carrito para comprarlos más tarde?
Responder: Sí, puede guardar artículos en su carrito para futuras compras. Al agregar artículos a su lista de deseos o guardarlos en su cuenta, podrá acceder fácilmente a ellos y comprarlos más tarde sin necesidad de buscarlos nuevamente.
- Consulta: ¿Cómo puedo ver la calificación promedio y las reseñas de los usuarios de un producto?
Responder: En la página de detalles del producto, puede ver la calificación promedio y las reseñas de los usuarios. Alentamos a los usuarios a compartir sus experiencias de compra y comentarios sobre los productos, para que pueda comprender mejor las opiniones y sugerencias de otros compradores.
Comentarios
- P
Paul Salerno
28/09/2025
Siemens Disyuntor 3RV2042-4FB10It was a no-brainer, it worked perfectly.ÚtilNo ayuda - E
ELENA GUIZAR
31/05/2025
Siemens Disyuntor 3RV2042-4FB10Quite remarkable!ÚtilNo ayuda - D
David Brightwell
11/03/2025
Siemens Disyuntor 3RV2042-4FB10Timely and dependable.ÚtilNo ayuda - C
Clara
03/06/2024
Siemens Disyuntor 3RV2042-4FB10I have to say, the quality of this free toolbox is great.ÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2042-4FB10¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2042-4FB10
$ 1,132 .75
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Siemens Disyuntor 3RV1041-4KA15
US$1030.73
Eaton Moeller Disyuntor E2KM3400W
US$4227.94
Fuji Disyuntor EW50SAG-3P005
US$113.85
Siemens Disyuntor 3WL1112-3CB36-4GA2
US$7597.66
CHINT Transformador TSGC2J-30
US$1269.25
Schneider Contactor LC2D12B7
US$192.31
Littelfuse Fusible 0154.500DR
US$2.88
ANLY Relé ASR-75RA-H
US$75.00
EBG Resistor UXP-600-200R
US$126.93
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
NSK Cojinete NN 3048 MBKRCC1P4
US$2496.15
UNID Válvula solenoide PKW-50
US$192.31
SICK Cortina de luz C40E-S306
US$5947.31
Bosch Rexroth Válvula solenoide 4WE6Y1X/ZG24N9K4
Contacta con nosotros
Parker Válvula proporcional RE06M17T2V1F026
Contacta con nosotros
Eaton Vickers Bomba de paletas 3525VQ35AM12-1AB20
Contacta con nosotros
EBARA Bomba de agua 80DF53.7
US$3846.15
NSK Cojinete 6311
US$326.92