Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 100 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 80...100 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S3 for motor protection, CLASS 10 A-release
80...100 A N-release 1300 A screw terminal Standard switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S3
size of contactor can be combined company-specific S3
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 44?W
at AC in hot operating state per pole 14.7?W
insulation voltage with degree of pollution 3 at AC
rated value
1?000?V
surge voltage resistance rated value 8?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 25?000
of auxiliary contacts typical 25?000
electrical endurance (switching cycles)
typical 25?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
80?...?100?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 100?A
operating current
at AC-3
at 400 V rated value 100?A
operating power
at AC-3
at 230 V rated value 30?000?W
at 400 V rated value 45?000?W at 690 V rated value 90?000?W
operating frequency
at AC-3 maximum 15?1/h
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 30?kA
at 500 V rated value 4?kA
at 690 V rated value 3?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 65?kA
at AC at 500 V rated value 8?kA
at AC at 690 V rated value 5?kA
response value current
of instantaneous short-circuit trip unit 1?300?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 100?A
at 600 V rated value 100?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 7.5?hp
at 230 V rated value 20?hp
for three-phase AC motor
at 200/208 V rated value 30?hp
at 220/230 V rated value 40?hp
at 460/480 V rated value 75?hp
at 575/600 V rated value 100?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 165?mm
width 70?mm
depth 176?mm
Circuit breaker size S3 for motor protection, CLASS 10 A-release
80...100 A N-release 1300 A screw terminal Standard switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S3
size of contactor can be combined company-specific S3
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 44?W
at AC in hot operating state per pole 14.7?W
insulation voltage with degree of pollution 3 at AC
rated value
1?000?V
surge voltage resistance rated value 8?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 25?000
of auxiliary contacts typical 25?000
electrical endurance (switching cycles)
typical 25?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
80?...?100?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 100?A
operating current
at AC-3
at 400 V rated value 100?A
operating power
at AC-3
at 230 V rated value 30?000?W
at 400 V rated value 45?000?W at 690 V rated value 90?000?W
operating frequency
at AC-3 maximum 15?1/h
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 30?kA
at 500 V rated value 4?kA
at 690 V rated value 3?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 65?kA
at AC at 500 V rated value 8?kA
at AC at 690 V rated value 5?kA
response value current
of instantaneous short-circuit trip unit 1?300?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 100?A
at 600 V rated value 100?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 7.5?hp
at 230 V rated value 20?hp
for three-phase AC motor
at 200/208 V rated value 30?hp
at 220/230 V rated value 40?hp
at 460/480 V rated value 75?hp
at 575/600 V rated value 100?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 165?mm
width 70?mm
depth 176?mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo buscar productos en el sitio web?
Responder: Puede utilizar la barra de búsqueda ubicada en la parte superior del sitio web para ingresar palabras clave y encontrar los productos deseados. Alternativamente, puede navegar a través de diferentes categorías y filtrar opciones para limitar su búsqueda.
- Consulta: ¿Admiten envíos internacionales?
Responder: Sí, admitimos envíos internacionales. Puede seleccionar la opción de envío internacional y proporcionar la dirección de envío correspondiente durante el proceso de pago. Tenga en cuenta que el envío internacional puede requerir tarifas y tiempo adicionales.
- Consulta: ¿Cómo puedo verificar el estado de mi artículo pendiente?
Responder: Para verificar el estado de su artículo pendiente, comuníquese con nuestro equipo de servicio al cliente. Le proporcionarán la información más reciente sobre la disponibilidad y la fecha estimada de envío del artículo.
Comentarios
- C
Carl Muntz
12/10/2025
Siemens Disyuntor 3RV2041-4MA10Thanks, I really appreciate it!ÚtilNo ayuda - C
Christina Viveiros
07/10/2025
Siemens Disyuntor 3RV2041-4MA10Thanks, I really appreciate your support.ÚtilNo ayuda - J
Jonathan Aldrich
09/05/2025
Siemens Disyuntor 3RV2041-4MA10Outstanding work!ÚtilNo ayuda - S
Sonia
23/09/2024
Siemens Disyuntor 3RV2041-4MA10Very good !! Thanks!ÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2041-4MA10¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2041-4MA10
$ 816 .50
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Siemens Disyuntor 5SL6232-7CC
US$38.67
Siemens Disyuntor 3RV5341-4KC10
US$226.76
ABB Disyuntor XT2N160 LSIG R25 FF 3P
US$639.45
TRIAD Transformador FP16-375
US$39.88
Eaton Contactor DILM7-10N
US$76.92
Littelfuse Fusible 0326012.MXP
US$5.75
OEG Relé ORWH-SS-124DM
US$0.38
UniOhm Resistor 1W150K
US$2.31
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Honeywell Actuator M9185A1018/U
Contacta con nosotros
SAND Transmisor PT322-M22-285MPa-152/460
Contacta con nosotros
NKK Interruptor M2012TJW01-GA-1A
US$13.80
CHINT Contactor CJX2-0901
US$94.80
ULVAC Bomba de Vacío PMB600DT-MD4J1R4I4B1
Contacta con nosotros
Yaskawa Servo Motor SGMP-01U314C
US$692.31