Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 40 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 32...40 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S2 for motor protection, CLASS 10 A-release
42...52 A N-release 741 A screw terminal increased switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 24.5?W
at AC in hot operating state per pole 8.2?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
42?...?52?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 52?A
operating current
at AC-3
at 400 V rated value 52?A
operating power
at AC-3
at 230 V rated value 15?000?W
at 400 V rated value 22?000?W
at 500 V rated value 30?000?W
at 690 V rated value 45?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 5?kA
at 690 V rated value 4?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 741?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 52?A
at 600 V rated value 52?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 5?hp
at 230 V rated value 10?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 20?hp
at 460/480 V rated value 40?hp
at 575/600 V rated value 50?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 160
at 500 V 125
at 690 V 100
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Circuit breaker size S2 for motor protection, CLASS 10 A-release
42...52 A N-release 741 A screw terminal increased switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 24.5?W
at AC in hot operating state per pole 8.2?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
42?...?52?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 52?A
operating current
at AC-3
at 400 V rated value 52?A
operating power
at AC-3
at 230 V rated value 15?000?W
at 400 V rated value 22?000?W
at 500 V rated value 30?000?W
at 690 V rated value 45?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 5?kA
at 690 V rated value 4?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 741?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 52?A
at 600 V rated value 52?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 5?hp
at 230 V rated value 10?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 20?hp
at 460/480 V rated value 40?hp
at 575/600 V rated value 50?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 160
at 500 V 125
at 690 V 100
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo filtrar productos por rango de precios?
Responder: En la página de listado de productos, puede utilizar la herramienta de filtrado de precios para establecer el rango de precios deseado. El sistema mostrará los productos que cumplan con sus criterios, ayudándole a encontrar los artículos adecuados rápidamente.
- Consulta: ¿Cómo puedo consultar la cobertura de garantía de un producto?
Responder: La cobertura de garantía de un producto generalmente se especifica en la página de detalles del producto o en la información de garantía proporcionada por el fabricante. Puede revisar esta información antes de realizar una compra para comprender la cobertura de la garantía.
- Consulta: ¿Qué debo hacer si recibo un producto dañado o defectuoso?
Responder: En el raro caso de que reciba un producto dañado o defectuoso, comuníquese con nuestro servicio de atención al cliente de inmediato. Le ayudaremos a resolver el problema organizando una devolución, reemplazo o reparación, según las circunstancias.
Comentarios
- L
Luke Masters
22/06/2025
Siemens Disyuntor 3RV2032-4WA15Piece of cake, no sweat!ÚtilNo ayuda - D
Dale Woolford
18/06/2025
Siemens Disyuntor 3RV2032-4WA15You're a genius.ÚtilNo ayuda - C
Carl Muntz
31/05/2025
Siemens Disyuntor 3RV2032-4WA15First-classÚtilNo ayuda - R
Rodrigo
09/02/2024
Siemens Disyuntor 3RV2032-4WA15Rápido y fácil! Buenos precios!!!ÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2032-4WA15¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2032-4WA15
$ 745 .86
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Mitsubishi Disyuntor NV400-SW 3P 250A
US$1332.03
Siemens Disyuntor 3RV2011-0JA20
US$207.02
Siemens Disyuntor 3RV2021-4EA10
US$428.33
Tamura Transformador 3FL16-350
US$52.50
Fuji Contactor SC-E05P-G-C
US$57.69
Fuji Fusible CS15F-1250-P
US$103.85
REXROTH Relé HED8OH15/50K14AS
US$335.85
IRC Resistor 20220516 56K
US$14.62
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Panasonic Servoaccionamiento MSD023A1XX
US$1076.92
CHANTO Cilindro de aire GSM63X500
Contacta con nosotros
Eaton Contactor C80DD110A22
Contacta con nosotros
HYDAC Transmisor EDS3446-3-0400-000
US$976.56
Fuji VFD Frequency Converter FRN200F1H-4A511
Contacta con nosotros
Copeland Compresor 4MTL-05-EWL-P
Contacta con nosotros
NORGREN Cilindro de aire SPC/020058/145
Contacta con nosotros