Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 40 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 32...40 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S2 for motor protection, CLASS 10 A-release
42...52 A N-release 741 A screw terminal increased switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 24.5?W
at AC in hot operating state per pole 8.2?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
42?...?52?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 52?A
operating current
at AC-3
at 400 V rated value 52?A
operating power
at AC-3
at 230 V rated value 15?000?W
at 400 V rated value 22?000?W
at 500 V rated value 30?000?W
at 690 V rated value 45?000?W
operating frequency
at AC-3 maximum 15?1/h
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 5?kA
at 690 V rated value 4?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 741?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 52?A
at 600 V rated value 52?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 5?hp
at 230 V rated value 10?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 20?hp
at 460/480 V rated value 40?hp
at 575/600 V rated value 50?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 160
at 500 V 125
at 690 V 100
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Circuit breaker size S2 for motor protection, CLASS 10 A-release
42...52 A N-release 741 A screw terminal increased switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 24.5?W
at AC in hot operating state per pole 8.2?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
42?...?52?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 52?A
operating current
at AC-3
at 400 V rated value 52?A
operating power
at AC-3
at 230 V rated value 15?000?W
at 400 V rated value 22?000?W
at 500 V rated value 30?000?W
at 690 V rated value 45?000?W
operating frequency
at AC-3 maximum 15?1/h
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 5?kA
at 690 V rated value 4?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 741?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 52?A
at 600 V rated value 52?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 5?hp
at 230 V rated value 10?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 20?hp
at 460/480 V rated value 40?hp
at 575/600 V rated value 50?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 160
at 500 V 125
at 690 V 100
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo cambiar mi dirección de correo electrónico asociada a mi cuenta?
Responder: Para cambiar la dirección de correo electrónico asociada a su cuenta, comuníquese con nuestro equipo de servicio al cliente y proporcióneles la información de verificación necesaria. Ellos le ayudarán a actualizar su dirección de correo electrónico.
- Consulta: ¿Puedo guardar artículos en mi carrito para comprarlos más tarde?
Responder: Sí, puede guardar artículos en su carrito para futuras compras. Al agregar artículos a su lista de deseos o guardarlos en su cuenta, podrá acceder fácilmente a ellos y comprarlos más tarde sin necesidad de buscarlos nuevamente.
- Consulta: ¿Cómo puedo ver la calificación promedio y las reseñas de los usuarios de un producto?
Responder: En la página de detalles del producto, puede ver la calificación promedio y las reseñas de los usuarios. Alentamos a los usuarios a compartir sus experiencias de compra y comentarios sobre los productos, para que pueda comprender mejor las opiniones y sugerencias de otros compradores.
Comentarios
- P
Peggy Walling
28/10/2025
Siemens Disyuntor 3RV2032-4WA10I can’t express my gratitude enough!ÚtilNo ayuda - M
Michelle Marques
30/09/2025
Siemens Disyuntor 3RV2032-4WA10That's the secret to success.ÚtilNo ayuda - C
Christy Resnik
05/09/2025
Siemens Disyuntor 3RV2032-4WA10I had an amazing time! I'll be back for more.ÚtilNo ayuda - C
Catalina
18/07/2024
Siemens Disyuntor 3RV2032-4WA10Easy checkoutÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2032-4WA10¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2032-4WA10
$ 708 .18
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Siemens Disyuntor 3RV1021-1JA15
US$403.36
GE Disyuntor FDN36TD125GD
US$353.85
Fuji Disyuntor EG103F-3P100
US$103.85
CHINT Transformador JMB-50
US$20.75
CHINT Contactor CJ20-250
US$840.66
Tyco Fusible NANOSMDC110F-2
US$0.58
ABB Relé CR-MX024AC4
US$19.23
Caddock Resistor MP925-20.0K-1%
US$9.63
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
MINDMAN Cilindro de aire MCQA-21-200-45M
US$369.23
Eaton Vickers Bomba de paletas 2520VQ14AM14S-11AD20
Contacta con nosotros
Keyence Sensor OP-85137
US$375.00
Copeland Compresor CR22K6E-TFE-267
Contacta con nosotros
OKAZAKI Herramienta para cortar metales CSRM0097
Contacta con nosotros