Mejores selecciones
1/1
Siemens Disyuntor 3RV2031-4UB15
$ 651 .14
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 40 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 32...40 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S2 for motor protection class 20 A-release
32...40 A N-release 585 A screw terminal Standard switching
capacity with transverse auxiliary switch 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 20?W
at AC in hot operating state per pole 6.7?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
32?...?40?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 40?A
operating current
at AC-3
at 400 V rated value 40?A
operating power
at AC-3
at 230 V rated value 11?000?W
at 400 V rated value 18?500?W
at 500 V rated value 22?000?W
at 690 V rated value 37?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class Class 20
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 30?kA
at 500 V rated value 5?kA
at 690 V rated value 2?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 65?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 4?kA
response value current
of instantaneous short-circuit trip unit 585?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 40?A
at 600 V rated value 40?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 3?hp
at 230 V rated value 7.5?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 15?hp
at 460/480 V rated value 30?hp
at 575/600 V rated value 40?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 125
at 500 V 100
at 690 V 80
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Circuit breaker size S2 for motor protection class 20 A-release
32...40 A N-release 585 A screw terminal Standard switching
capacity with transverse auxiliary switch 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 20?W
at AC in hot operating state per pole 6.7?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
32?...?40?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 40?A
operating current
at AC-3
at 400 V rated value 40?A
operating power
at AC-3
at 230 V rated value 11?000?W
at 400 V rated value 18?500?W
at 500 V rated value 22?000?W
at 690 V rated value 37?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class Class 20
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 30?kA
at 500 V rated value 5?kA
at 690 V rated value 2?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 65?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 4?kA
response value current
of instantaneous short-circuit trip unit 585?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 40?A
at 600 V rated value 40?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 3?hp
at 230 V rated value 7.5?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 15?hp
at 460/480 V rated value 30?hp
at 575/600 V rated value 40?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 125
at 500 V 100
at 690 V 80
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo ver el tamaño y las especificaciones de un producto?
Responder: En la página de detalles del producto, puede encontrar información detallada sobre el tamaño y las especificaciones, incluidas tablas de tamaños, medidas específicas y más, para ayudarlo a seleccionar el producto correcto.
- Consulta: ¿Cómo puedo rastrear mi pedido?
Responder: Una vez que se envíe su pedido, recibirá un correo electrónico de confirmación con información de seguimiento. Puede utilizar esta información para realizar un seguimiento de su pedido a través del sitio web del proveedor de logística.
- Consulta: ¿Ofrecéis servicios de instalación para determinados productos?
Responder: Desafortunadamente, no brindamos directamente servicios de instalación de productos. La disponibilidad de los servicios de instalación generalmente se menciona en la página del producto. Si realmente necesita ayuda con la instalación, comuníquese con nuestro equipo de servicio al cliente para obtener información y arreglos más detallados. Le brindaremos asistencia activamente .
Comentarios
- M
Matthew Torres
28/09/2025
Siemens Disyuntor 3RV2031-4UB15The product will be shipped out shortly.ÚtilNo ayuda - M
MARGARET GEORGE
23/09/2025
Siemens Disyuntor 3RV2031-4UB15I'm loving the present moment.ÚtilNo ayuda - W
William Geltz
19/02/2025
Siemens Disyuntor 3RV2031-4UB15Quick and easy shippingÚtilNo ayuda - N
Natalia
14/06/2024
Siemens Disyuntor 3RV2031-4UB15niceÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2031-4UB15¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2031-4UB15
$ 651 .14
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Fuji Disyuntor BW32SAG-3P010
US$56.54
Siemens Disyuntor 3RV2011-1JA20
US$256.38
Schneider Disyuntor A9D93632
US$450.00
Fuji Disyuntor EW50EAG-3P032
US$89.23
Schneider Transformador ABL6TS250G
US$640.55
Eaton Contactor DILM170C(RDC24)
US$515.38
Littelfuse Fusible LMF3.2
US$3.85
HONGFA Relé HF116F-G2-24-1HTF
US$26.92
Yageo Resistor MFR-50DTE52-562R
US$76.92
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Saginomiya Válvula de expansión ATX-34013BHCY
Contacta con nosotros
Schneider Sensor XS1N05NB310
US$143.08
Copeland Compresor ZP39K5E-TFE-498
Contacta con nosotros
Meas Transmisor P499CDJA501C0
Contacta con nosotros
IMI Norgren Válvula solenoide UM/22354/22/61
Contacta con nosotros
VBI Cojinete 6013-2Z
US$18.46