Mejores selecciones
1/1
Siemens Disyuntor 3RV2031-4PA15
$ 511 .77
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 36 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 28...36 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S2 for motor protection, CLASS 10 A-release
28...36 A N-release 520 A screw terminal Standard switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 20?W
at AC in hot operating state per pole 6.7?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
28?...?36?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 36?A
operating current
at AC-3
at 400 V rated value 36?A
operating power
at AC-3
at 400 V rated value 18?500?W
at 500 V rated value 22?000?W
at 690 V rated value 30?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 30?kA
at 500 V rated value 5?kA
at 690 V rated value 2?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 65?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 4?kA
response value current
of instantaneous short-circuit trip unit 520?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 36?A
at 600 V rated value 36?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 3?hp
at 230 V rated value 7.5?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 15?hp
at 460/480 V rated value 30?hp
at 575/600 V rated value 40?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 125
at 500 V 100
at 690 V 80
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Circuit breaker size S2 for motor protection, CLASS 10 A-release
28...36 A N-release 520 A screw terminal Standard switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 20?W
at AC in hot operating state per pole 6.7?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
28?...?36?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 36?A
operating current
at AC-3
at 400 V rated value 36?A
operating power
at AC-3
at 400 V rated value 18?500?W
at 500 V rated value 22?000?W
at 690 V rated value 30?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 30?kA
at 500 V rated value 5?kA
at 690 V rated value 2?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 65?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 4?kA
response value current
of instantaneous short-circuit trip unit 520?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 36?A
at 600 V rated value 36?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 3?hp
at 230 V rated value 7.5?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 15?hp
at 460/480 V rated value 30?hp
at 575/600 V rated value 40?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 125
at 500 V 100
at 690 V 80
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo ver el tamaño y las especificaciones de un producto?
Responder: En la página de detalles del producto, puede ver el tamaño y las especificaciones del producto. Por lo general, proporcionamos tablas de tallas detalladas y descripciones de especificaciones para ayudarlo a elegir el producto correcto.
- Consulta: ¿Cómo puedo verificar el estado de mi reclamo de garantía?
Responder: Para verificar el estado de su reclamo de garantía, comuníquese con nuestro equipo de servicio al cliente y proporcióneles los detalles necesarios, como su número de reclamo de garantía o información del pedido. Le ayudarán a seguir el progreso de su reclamo.
- Consulta: ¿Existen restricciones de cantidad mínima de pedido para comprar ciertos productos?
Responder: Sí, para ciertos productos, es posible que existan restricciones de cantidad mínima de pedido. Esto garantiza un procesamiento eficiente y rentabilidad para ambas partes involucradas. Verifique los detalles del producto o comuníquese con nuestro equipo de ventas para obtener información específica sobre las cantidades mínimas de pedido.
Comentarios
- L
LISA LANCASTER
12/07/2025
Siemens Disyuntor 3RV2031-4PA15Friendly crowdÚtilNo ayuda - C
Chad Folstad
18/05/2025
Siemens Disyuntor 3RV2031-4PA15Quick shipment.ÚtilNo ayuda - J
Joe Campbell
10/05/2025
Siemens Disyuntor 3RV2031-4PA15I located the grill here when no other site had it.ÚtilNo ayuda - C
Carolina
24/04/2024
Siemens Disyuntor 3RV2031-4PA15good priceÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2031-4PA15¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2031-4PA15
$ 511 .77
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Siemens Disyuntor 3RV1011-1EA10
US$324.91
Fuji Disyuntor EW63EAG-3P063
US$199.00
Eaton Moeller Disyuntor PL9-C2-DC
US$27.57
Siemens Contactor 3RT2017-2AH02
US$186.54
IDEC Relé RJ2V-C-D24
US$14.23
UniOhm Resistor 0603WAJ0624T5E
US$14.46
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
ATOS Válvula proporcional AGMZA/M-A-10/80/M
Contacta con nosotros
HONGFA Relé HF179F-5-H2TF
US$5.38
Renishaw Codificador RGH40N15D62G
Contacta con nosotros
Danfoss Compresor MT36HW4D
US$1725.35
Kompass Bomba de paletas T6DC-031-020-1R00-B1
Contacta con nosotros
Beckhoff Módulo Fieldbus Box And Io-Link Box Compact Box Digital Combi IP2312-B810
Contacta con nosotros
SEW Servo Motor PSE212/N/EK03DS56M/B/TF/RH1M/SB10
Contacta con nosotros
KMP Bomba de agua 80X50-315
US$3577.31