Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 0.63 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 0.45...0.63 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S00 for motor protection, CLASS 10 A-release
0.45...0.63 A N-release 8.2 A screw terminal Standard switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at AC
rated value
690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400V
in networks with grounded star point between
main and auxiliary circuit
400 V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles)
typical 100 000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2 000 m
ambient temperature
during operation -20 ... +60 degrees centigrade
during storage -50 ... +80 degrees centigrade
during transport -50 ... +80 degrees centigrade
temperature compensation -20 ... +60 degrees centigrade
relative humidity during operation 10 ... 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent
overload release
0.45 ... 0.63 A
operating voltage
rated value 690 V
at AC-3 rated value maximum 690 V
operating frequency rated value 50 ... 60 Hz
operating current rated value 0.63 A
operating current
at AC-3
at 400 V rated value 0.63 A
operating power
at AC-3
at 230 V rated value 90 W
at 400 V rated value 180 W
at 500 V rated value 180 W
at 690 V rated value 250 W
operating frequency
at AC-3 maximum 15 1/h
Auxiliary circuit
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 8.2 A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.63 A
at 600 V rated value 0.63 A
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 690 V gL/gG 6 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97 mm
width 45 mm
depth 97 mm
required spacing
for grounded parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for grounded parts at 500 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 500 V downwards 30 mm
upwards 30 mm at the side 9 mm
for grounded parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm
for live parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm
Connections/ Terminals
product function
removable terminal for auxiliary and control
circuit
No
type of electrical connection
for main current circuit screw-type terminals
arrangement of electrical connectors for main current
circuit
Top and bottom
type of connectable conductor cross-sections
for main contacts
single or multi-stranded 2x (0,75 ... 2,5 mm?), 2x 4 mm?
finely stranded with core end processing 2x (0.5 ... 1.5 mm?), 2x (0.75 ... 2.5 mm?)
at AWG conductors for main contacts 2x (18 ... 14), 2x 12
tightening torque
for main contacts with screw-type terminals 0.8 ... 1.2 N.m
design of screwdriver shaft Diameter 5 to 6 mm
size of the screwdriver tip Pozidriv 2
design of the thread of the connection screw
for main contacts M3
Safety related data
B10 value
with high demand rate acc. to SN 31920 5 000
proportion of dangerous failures
with low demand rate acc. to SN 31920 50 %
with high demand rate acc. to SN 31920 50 %
failure rate FIT
with low demand rate acc. to SN 31920 50 FIT
T1 value for proof test interval or service life acc. to
IEC 61508
10 y
display version
for switching status Handle
Circuit breaker size S00 for motor protection, CLASS 10 A-release
0.45...0.63 A N-release 8.2 A screw terminal Standard switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at AC
rated value
690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400V
in networks with grounded star point between
main and auxiliary circuit
400 V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles)
typical 100 000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2 000 m
ambient temperature
during operation -20 ... +60 degrees centigrade
during storage -50 ... +80 degrees centigrade
during transport -50 ... +80 degrees centigrade
temperature compensation -20 ... +60 degrees centigrade
relative humidity during operation 10 ... 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent
overload release
0.45 ... 0.63 A
operating voltage
rated value 690 V
at AC-3 rated value maximum 690 V
operating frequency rated value 50 ... 60 Hz
operating current rated value 0.63 A
operating current
at AC-3
at 400 V rated value 0.63 A
operating power
at AC-3
at 230 V rated value 90 W
at 400 V rated value 180 W
at 500 V rated value 180 W
at 690 V rated value 250 W
operating frequency
at AC-3 maximum 15 1/h
Auxiliary circuit
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 8.2 A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.63 A
at 600 V rated value 0.63 A
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 690 V gL/gG 6 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97 mm
width 45 mm
depth 97 mm
required spacing
for grounded parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for grounded parts at 500 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 500 V downwards 30 mm
upwards 30 mm at the side 9 mm
for grounded parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm
for live parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm
Connections/ Terminals
product function
removable terminal for auxiliary and control
circuit
No
type of electrical connection
for main current circuit screw-type terminals
arrangement of electrical connectors for main current
circuit
Top and bottom
type of connectable conductor cross-sections
for main contacts
single or multi-stranded 2x (0,75 ... 2,5 mm?), 2x 4 mm?
finely stranded with core end processing 2x (0.5 ... 1.5 mm?), 2x (0.75 ... 2.5 mm?)
at AWG conductors for main contacts 2x (18 ... 14), 2x 12
tightening torque
for main contacts with screw-type terminals 0.8 ... 1.2 N.m
design of screwdriver shaft Diameter 5 to 6 mm
size of the screwdriver tip Pozidriv 2
design of the thread of the connection screw
for main contacts M3
Safety related data
B10 value
with high demand rate acc. to SN 31920 5 000
proportion of dangerous failures
with low demand rate acc. to SN 31920 50 %
with high demand rate acc. to SN 31920 50 %
failure rate FIT
with low demand rate acc. to SN 31920 50 FIT
T1 value for proof test interval or service life acc. to
IEC 61508
10 y
display version
for switching status Handle
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo consultar la fecha de producción o fecha de vencimiento de un producto?
Responder: Para comprobar la fecha de producción o la fecha de caducidad de un producto, puede consultar el embalaje o las etiquetas del producto. Proporcionamos información clara y precisa sobre la fecha de fabricación y la fecha de vencimiento, lo que le permite tomar decisiones de compra informadas. Si necesita más ayuda, nuestro equipo de atención al cliente siempre está listo para ayudar.
- Consulta: ¿El producto tiene garantía de calidad?
Responder: ¡Absolutamente! Estamos orgullosos de ofrecer productos de alta calidad. Cada producto se somete a rigurosos controles de calidad para garantizar la excelencia y la satisfacción del cliente. Respaldamos la calidad de nuestros productos.
- Consulta: ¿Cómo puedo enviar comentarios o reseñar un producto?
Responder: Puede proporcionar comentarios o reseñar un producto accediendo a la página del producto y haciendo clic en la opción "Escribir una reseña" o "Dejar comentarios". Comparta su experiencia y opiniones para ayudar a otros compradores a tomar decisiones informadas.
Comentarios
- W
Walters Sternlieb
04/05/2025
Siemens Disyuntor 3RV2011-0GA10Just what I was searching for.ÚtilNo ayuda - J
JACINTO CALDERIN
06/04/2025
Siemens Disyuntor 3RV2011-0GA10Rapid shipping, guaranteed!ÚtilNo ayuda - M
Malcolm Dorman
30/03/2025
Siemens Disyuntor 3RV2011-0GA10Exactly what I was looking for, thank you so much!ÚtilNo ayuda - L
Leticia
01/03/2024
Siemens Disyuntor 3RV2011-0GA10¡Fácil encontrar lo que necesitaba!ÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2011-0GA10¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2011-0GA10
$ 194 .61
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 2
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Fuji Disyuntor EW50RAGU-3P030B
US$626.92
Mitsubishi Disyuntor NF630-SEW 4P
US$962.11
Honeywell Disyuntor HMS-2C4
US$28.99
Terasaki Disyuntor XS100NB
US$346.15
TRIAD Transformador FP10-4800
US$60.75
Siemens Contactor 3TF6844-0CP7
US$4807.69
Ferraz Shawmut Fusible PC73UD10C900D1A
US$253.85
TYCO Relé OJE-SH-112DM,095
US$3.85
UniOhm Resistor 0.25W200K
US$19.23
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Rexroth Bomba de paletas PVV54-1X/154-098RJ15LDVB
Contacta con nosotros
Panasonic Resistor EXB-V8V112JV
Contacta con nosotros
Iwaki Bomba magnética MX-251AE6-2
US$1153.85
TYCO Relé SSFR90P
US$1195.00
BANDO Belt STS S5M-1135-15
US$48.85