Siemens Disyuntor 3RV2011-0DA40
$ 192 .44
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 0.32 |
| Número de polos | 4 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 0.22...0.32 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S00 for motor protection, CLASS 10 A-release
0.22...0.32 A N-release 4.2 A ring cable lug connection Standard
switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at AC
rated value
690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400 V
in networks with grounded star point between
main and auxiliary circuit
400 V
protection class IP
on the front IP00
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles)
typical 100 000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2 000 m
ambient temperature
during operation -20 ... +60 degrees centigrade
during storage -50 ... +80 degrees centigrade
during transport -50 ... +80 degrees centigrade
temperature compensation -20 ... +60 degrees centigrade
relative humidity during operation 10 ... 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent
overload release
0.22 ... 0.32 A
operating voltage
rated value 690 V
at AC-3 rated value maximum 690 V
operating frequency rated value 50 ... 60 Hz
operating current rated value 0.32 A
operating current
at AC-3
at 400 V rated value 0.32 A
operating power
at AC-3
at 230 V rated value 40 W
at 400 V rated value 90 W
at 500 V rated value 120 W
at 690 V rated value 120 W
operating frequency
at AC-3 maximum 15 1/h
Auxiliary circuit
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 4.2 A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.32 A
at 600 V rated value 0.32 A
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97 mm
width 45 mm
depth 97 mm
required spacing
for grounded parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for grounded parts at 500 V downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 500 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for grounded parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm for live parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm
Connections/ Terminals
product function
removable terminal for auxiliary and control
circuit
No
type of electrical connection
for main current circuit Ring cable lug connection
for auxiliary and control circuit ring cable connection
arrangement of electrical connectors for main current
circuit
Top and bottom
tightening torque
for main contacts for ring cable lug 0.8 ... 1.2 N.m
for auxiliary contacts for ring cable lug 1.2 ... 0.8 N.m
outer diameter of the usable ring cable lug maximum 7.5 mm
design of screwdriver shaft Diameter 5 to 6 mm
size of the screwdriver tip Size 2 and Pozidriv 2
design of the thread of the connection screw
for main contacts M3
of the auxiliary and control contacts M3
Safety related data
B10 value
with high demand rate acc. to SN 31920 5 000
proportion of dangerous failures
with low demand rate acc. to SN 31920 50 %
with high demand rate acc. to SN 31920 50 %
failure rate FIT
with low demand rate acc. to SN 31920 50 FIT
T1 value for proof test interval or service life acc. to
IEC 61508
10 y
display version
for switching status Handle
Circuit breaker size S00 for motor protection, CLASS 10 A-release
0.22...0.32 A N-release 4.2 A ring cable lug connection Standard
switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at AC
rated value
690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400 V
in networks with grounded star point between
main and auxiliary circuit
400 V
protection class IP
on the front IP00
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles)
typical 100 000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2 000 m
ambient temperature
during operation -20 ... +60 degrees centigrade
during storage -50 ... +80 degrees centigrade
during transport -50 ... +80 degrees centigrade
temperature compensation -20 ... +60 degrees centigrade
relative humidity during operation 10 ... 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent
overload release
0.22 ... 0.32 A
operating voltage
rated value 690 V
at AC-3 rated value maximum 690 V
operating frequency rated value 50 ... 60 Hz
operating current rated value 0.32 A
operating current
at AC-3
at 400 V rated value 0.32 A
operating power
at AC-3
at 230 V rated value 40 W
at 400 V rated value 90 W
at 500 V rated value 120 W
at 690 V rated value 120 W
operating frequency
at AC-3 maximum 15 1/h
Auxiliary circuit
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 4.2 A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.32 A
at 600 V rated value 0.32 A
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97 mm
width 45 mm
depth 97 mm
required spacing
for grounded parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for grounded parts at 500 V downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 500 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for grounded parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm for live parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm
Connections/ Terminals
product function
removable terminal for auxiliary and control
circuit
No
type of electrical connection
for main current circuit Ring cable lug connection
for auxiliary and control circuit ring cable connection
arrangement of electrical connectors for main current
circuit
Top and bottom
tightening torque
for main contacts for ring cable lug 0.8 ... 1.2 N.m
for auxiliary contacts for ring cable lug 1.2 ... 0.8 N.m
outer diameter of the usable ring cable lug maximum 7.5 mm
design of screwdriver shaft Diameter 5 to 6 mm
size of the screwdriver tip Size 2 and Pozidriv 2
design of the thread of the connection screw
for main contacts M3
of the auxiliary and control contacts M3
Safety related data
B10 value
with high demand rate acc. to SN 31920 5 000
proportion of dangerous failures
with low demand rate acc. to SN 31920 50 %
with high demand rate acc. to SN 31920 50 %
failure rate FIT
with low demand rate acc. to SN 31920 50 FIT
T1 value for proof test interval or service life acc. to
IEC 61508
10 y
display version
for switching status Handle
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo aplicar un cupón o código de descuento?
Responder: Durante el proceso de pago, encontrarás un campo para ingresar tu cupón o código de descuento. Ingrese el código y haga clic en "Aplicar" para ver el monto total actualizado.
- Consulta: ¿Cuánto tiempo lleva procesar un reembolso?
Responder: Nos esforzamos por procesar los reembolsos lo más rápido posible. Una vez que recibimos el producto devuelto, normalmente tardamos unos días hábiles en inspeccionarlo y procesar el reembolso. El plazo exacto puede variar según el método de pago y su institución financiera.
- Consulta: ¿Puedo comprar productos como invitado o necesito crear una cuenta?
Responder: Vaya, actualmente no admitimos el pago como invitado. Debe crear una cuenta para poder continuar con su pedido. Los beneficios de crear una cuenta incluyen un pago más rápido, la capacidad de realizar un seguimiento de los pedidos y ver el historial de pedidos. Sin embargo, si prefiere realizar el pago como invitado, puede consultar con nuestro personal de atención al cliente y ellos le brindarán la asistencia conveniente.
Comentarios
- J
Johnny Huynh
30/06/2025
Siemens Disyuntor 3RV2011-0DA40Excellent product, excellent price!ÚtilNo ayuda - K
Kathleen Hayes
18/04/2025
Siemens Disyuntor 3RV2011-0DA40Quick shipping with stock available for you.ÚtilNo ayuda - G
George Johnson
16/11/2024
Siemens Disyuntor 3RV2011-0DA40I'm feeling incredibly happy and relieved that I've found what I needed and it's now on its way to me.ÚtilNo ayuda - I
Iván
28/06/2024
Siemens Disyuntor 3RV2011-0DA40really helped us out in saving money compared to distributorÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2011-0DA40¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2011-0DA40
$ 192 .44
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 2
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Fuji Disyuntor BW32SAG-2P020
US$51.54
Fuji Disyuntor BW32SAG-2P015
US$51.54
Fuji Disyuntor EW32AAG-2P020
US$88.46
TRIAD Transformador FP16-3000
US$54.42
Schneider Contactor LC1E1201M5N
US$134.62
Littelfuse Fusible KLK5
US$25.30
HONGFA Relé HF3FD-009-ZST
US$0.54
UniOhm Resistor 0603WAJ0134T5E
US$4.42
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
UniOhm Resistor 25121WF2002T4E
Contacta con nosotros
Trafag Transmisor 8253.86.4120.01
Contacta con nosotros
Schneider Disyuntor A9F18250
US$250.00
Bristol Compresor H27A54QCBCR
Contacta con nosotros
HENGSTLER Codificador RI32-O/600AR.14KB
US$343.15
Parker Denison Bomba de paletas T7DDBS-B42-B42-B09-2R00-A5-M0
Contacta con nosotros