Mejores selecciones
Siemens Disyuntor 3RV1021-0BA10
$ 255 .30
(5) 1
Comentarios
Cantidad
MOQ : 2
Pagos
Parámetro
Tipo | 3RV1 |
Tipo de disyuntor | Motor Protection Circuit Breakers |
Corriente nominal | 0.2 |
Número de polos | 1 pole |
Rango de ajuste para disparadores de sobrecarga térmica | 0.14...0.2 A |
Adecuado para motores de inducción con P | 0.06 kW |
Liberaciones instantáneas de sobrecorriente | 2.6 A |
Short-circuit breaking capacidad | 100 kA |
Peso approx. | 0.288 kg |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S0 for motor protection CLASS 10 A-release0.14...0.2 A Short-circuit release 2.6 A
Screw terminal Standardswitching capacity Phased-out product Successor is SIRIUS3RV2 Preferred successor
type is 3RV2011-0BA10
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
General technical data
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
protection class IP
on the front IP20 mechanical service life (switching cycles)
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typica 100 000
continuous current rated value 0.2 A
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.14 - 0.2
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating current
at AC-3 at 400 V rated value 0.2 A
operating power at AC-3
at 400 V rated value 60 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 50022
height 97 mm width 45 mm depth 96 mm
Circuit breaker size S0 for motor protection CLASS 10 A-release0.14...0.2 A Short-circuit release 2.6 A
Screw terminal Standardswitching capacity Phased-out product Successor is SIRIUS3RV2 Preferred successor
type is 3RV2011-0BA10
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
General technical data
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
protection class IP
on the front IP20 mechanical service life (switching cycles)
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typica 100 000
continuous current rated value 0.2 A
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.14 - 0.2
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating current
at AC-3 at 400 V rated value 0.2 A
operating power at AC-3
at 400 V rated value 60 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 50022
height 97 mm width 45 mm depth 96 mm
Las personas que compraron este artículo también vieron
ABB Disyuntor SH201-D6
US$16.80
Schneider Disyuntor LS8F09420G
US$375.00
GE Disyuntor G63 C06
US$53.85
GE Disyuntor FDL36TD040ED
US$436.54
Tamura Transformador MET-59
US$48.00
Schneider Contactor LC1DWK12F7C
US$221.15
Siemens Fusible 5SE2325
US$9.20
TYCO Relé IM41GR
US$2.50
UniOhm Resistor 0.5W100K
US$5.77
Los clientes ven con frecuencia
Carel Válvula de expansión E6VB2ASV00
US$839.00
Mitsubishi Compresor RE277NRAMT
US$389.00
Togami Contactor CLK-25J3
US$79.00
SUNON Ventilador MF92252V3-1000C-A99
US$24.23
TAKEX Sensor FR520C-3J
US$207.00
ABB Arrancador suave PSR105-600-11
US$1326.92
ULVAC Bomba de Vacío GHD-031A
US$4615.38
Publicaciones relacionadas recientes
-
08/04/2023
Aire acondicionado Mitsubishi vs Panasonic
El verano es tan difícil de pasar que las personas sin aire acondicionado son como peces fuera del agua. Es fundamental elegir un buen aire acondicionado.
-
12/05/2023
Principios y diferencias de los transmisores de 2, 3 y 4 hilos
Los transmisores de 2, 3 y 4 hilos se refieren a transmisores cuyas salidas son señales analógicas de corriente CC.
-
05/19/2022
17 fabricantes de compresores centrífugos, en el mundo. ¿cuántos conoce?
En la última década, en un contexto de globalización económica y feroz competencia, la industria de fabricación de compresores centrífugos también ha experimentado continuas fusiones, adquisiciones y reorganizaciones.
-
03/10/2024
Todo lo que debe saber sobre el embrague magnético del compresor de CA del coche
Este artículo presenta los componentes del embrague magnético del compresor y su principio de funcionamiento, así como varios parámetros importantes. Además, también le brindamos algunas experiencias sobre cómo lidiar con la quema de los embragues del compresor del aire acondicionado.
-
11/18/2023
Transmisores Rosemount Series 1151, 2088, 2051, 3051CA, 3051S y sus diferencias
El transmisor de presión Rosemount es un tipo de transmisor de presión general. Está fabricado según la ley de inducción electromagnética y la norma JB/T9248-1999.
-
08/08/2023
Método de cálculo del peso por metro de tubo de cobre para aire acondicionado
Método de cálculo del peso por metro de tubería de cobre para aire acondicionado.
-
07/29/2023
Compresor Scroll Vs. Compresor rotativo para CA
El compresor scrollue inventado en 1905 por el francés Copeland. Creó la compañía Copeland en los Estados Unidos, donde se utilizan principalmente acondicionadores de aire de agua
-
01/08/2024
¿Por qué vibra el servomotor?
¿En qué casos vibrará un servomotor? ¿Qué pasa si el servomotor vibra? ¿Cómo podemos solucionar los problemas causados por la vibración? Este artículo explicará varias razones para esto.
-
06/27/2023
Principio de funcionamiento del compresor frigorífico, esquema eléctrico, estructura
El componente principal del refrigerador es el compresor. Si un frigorífico no está equipado con un compresor de buena calidad y tecnología no puede ser un buen frigorífico.
-
05/12/2022
Reparación de averías en servoaccionamientos Ultra3000
Hemos enumerado las fallas comunes y los métodos de reparación de los servovariadores Ultra3000; si necesita reemplazar el equipo, le brindamos Servoaccionamiento Allen Bradley Rockwell.