Parámetro
| Tipo | 3RV1 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 10 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 7...10 A |
| Adecuado para motores de inducción con P | 4 kW |
| Liberaciones instantáneas de sobrecorriente | 130 A |
| Short-circuit breaking capacidad | 50 kA |
| Peso approx. | 0.3 kg |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S00 for motor protection, CLASS 10 A-release7...10 A N release 130 A Screw terminal Standard switching capacitywith transverse auxiliary switch 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 9.25 W
at AC in hot operating state per pole 3.1 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 7 - 10
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value 10A
operating current
at AC-3 at 400 V rated value 10 A
operating power at AC-3
at 230 V rated value 2200 W
at 400 V rated value 4000 W
at 500 V rated value 5500 W
at 690 V rated value 7500 W
operating frequency at AC-3 maximum 15 1/h
design of the auxiliary switcht ransverse
number of NC contacts for auxiliary contact 1 note 1
number of NO contacts for auxiliary contacts 1 note 1
number of CO contacts for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 2 A at 110 V 2 A at 120 V 2 A at 125 V 2 A at 230 V 0.5 A
operating current of auxiliary contacts at DC-13
at 24 V 1 A at 60 V 0.15 A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 12.5 kA
at 500 V rated value 3 kA
at 690 V rated value 2 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 50 kA
at AC at 500 V rated value 3 kA
at AC at 690 V rated value 2 kA
response value current
of instantaneous short-circuit trip unit 130 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 10A
at 600 V rated value 10A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 0.5 hp
at 230 V rated value 1.5 hp
for three-phase AC motor
at 200/208 V rated value 2 hp
at 220/230 V rated value 3 hp
at 460/480 V rated value 5 hp
at 575/600 V rated value 7.5 hp
contact rating of auxiliary contacts according to UL C300 R300
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switchrequired
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit currentIk less 400 A)
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V gL/gG 80 A
at 400 V gL/gG 63 A
at 500 V gL/gG 50 A
at 690 V gL/gG 50 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 9.25 W
at AC in hot operating state per pole 3.1 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 7 - 10
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value 10A
operating current
at AC-3 at 400 V rated value 10 A
operating power at AC-3
at 230 V rated value 2200 W
at 400 V rated value 4000 W
at 500 V rated value 5500 W
at 690 V rated value 7500 W
operating frequency at AC-3 maximum 15 1/h
design of the auxiliary switcht ransverse
number of NC contacts for auxiliary contact 1 note 1
number of NO contacts for auxiliary contacts 1 note 1
number of CO contacts for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 2 A at 110 V 2 A at 120 V 2 A at 125 V 2 A at 230 V 0.5 A
operating current of auxiliary contacts at DC-13
at 24 V 1 A at 60 V 0.15 A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 12.5 kA
at 500 V rated value 3 kA
at 690 V rated value 2 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 50 kA
at AC at 500 V rated value 3 kA
at AC at 690 V rated value 2 kA
response value current
of instantaneous short-circuit trip unit 130 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 10A
at 600 V rated value 10A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 0.5 hp
at 230 V rated value 1.5 hp
for three-phase AC motor
at 200/208 V rated value 2 hp
at 220/230 V rated value 3 hp
at 460/480 V rated value 5 hp
at 575/600 V rated value 7.5 hp
contact rating of auxiliary contacts according to UL C300 R300
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switchrequired
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit currentIk less 400 A)
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V gL/gG 80 A
at 400 V gL/gG 63 A
at 500 V gL/gG 50 A
at 690 V gL/gG 50 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo buscar productos en el sitio web?
Responder: Puede utilizar la barra de búsqueda ubicada en la parte superior del sitio web para ingresar palabras clave y encontrar los productos deseados. Alternativamente, puede navegar a través de diferentes categorías y filtrar opciones para limitar su búsqueda.
- Consulta: ¿Admiten envíos internacionales?
Responder: Sí, admitimos envíos internacionales. Puede seleccionar la opción de envío internacional y proporcionar la dirección de envío correspondiente durante el proceso de pago. Tenga en cuenta que el envío internacional puede requerir tarifas y tiempo adicionales.
- Consulta: ¿Cómo puedo verificar el estado de mi artículo pendiente?
Responder: Para verificar el estado de su artículo pendiente, comuníquese con nuestro equipo de servicio al cliente. Le proporcionarán la información más reciente sobre la disponibilidad y la fecha estimada de envío del artículo.
Comentarios
- R
Ronny Montgomery
07/09/2025
Siemens Disyuntor 3RV1011-1JA15Couldn’t be happier with the overall experience!ÚtilNo ayuda - J
Joshua Sealey
03/03/2025
Siemens Disyuntor 3RV1011-1JA15Excellent, just what we were looking forÚtilNo ayuda - C
Carl Howat
02/03/2025
Siemens Disyuntor 3RV1011-1JA15The customer service team provided fantastic guidance on selecting the right thermostat.ÚtilNo ayuda - E
Emilia
27/04/2024
Siemens Disyuntor 3RV1011-1JA15Mi pedido llegó puntualmente, era lo que había pedido y funcionaba perfectamenteÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV1011-1JA15¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV1011-1JA15
$ 443 .06
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Eaton Moeller Disyuntor PL9-C4
US$43.38
GE Disyuntor GPS1BHAM 11-16A
US$529.00
Siemens Disyuntor 3VU1340-1TL00
US$187.89
TRIAD Transformador TCT50-05E07AE
US$58.00
Schneider Contactor LC1N1201F5N
US$47.69
Ferraz Shawmut Fusible PC36UD60V22CP11
US$423.08
SHARP Relé S105T01
US$11.54
UniOhm Resistor 0805W8J0205T5E
US$10.00
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Copeland Compresor ZPS122KCE-TFD-250
Contacta con nosotros
SMC Válvula solenoide VFR2100-4FZ-02
US$269.23
KAYDON Cojinete SB040CP0
US$38.08
Huaguang Compresor EYA60
US$147.31
Carrier Compresor 06DF8252DC0600
Contacta con nosotros
Dwyer Interruptor A6-451221
US$138.46
Fuji VFD Frequency Converter FRN001C1J-6A2
Contacta con nosotros
CHANTO Cilindro de aire GXS12X10
Contacta con nosotros