Mejores selecciones
Siemens Disyuntor 3RV1011-1FA15
$ 401 .21
(5) 1
Comentarios
Cantidad
MOQ : 1
Pagos
Parámetro
Tipo | 3RV1 |
Tipo de disyuntor | Motor Protection Circuit Breakers |
Corriente nominal | 5 |
Número de polos | 1 pole |
Rango de ajuste para disparadores de sobrecarga térmica | 3.5...5 A |
Adecuado para motores de inducción con P | 1.5 kW |
Liberaciones instantáneas de sobrecorriente | 65 A |
Short-circuit breaking capacidad | 100 kA |
Peso approx. | 0.301 kg |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S00 for motor protection, CLASS 10 A-release3.5...5 A
N release 65 A 1 NO+1 NC transverse Screw terminalStandard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 3.5 - 5
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value5A
operating current
at AC-3 at 400 V rated value 5 A
operating power at AC-3
at 230 V rated value 1100 W
at 400 V rated value 1500 W
at 500 V rated value 2200 W
at 690 V rated value 4000 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 3 kA
at 690 V rated value 2 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 3 kA
at AC at 690 V rated value 2 kA
response value current
of instantaneous short-circuit trip unit 65 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value5A
at 600 V rated value5 A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 0.166 hp
at 230 V rated value 0.5 hp
for three-phase AC motor
at 200/208 V rated value 1 hp
at 220/230 V rated value 1 hp
at 460/480 V rated value 3 hp
at 575/600 V rated value 3 hp
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switchrequired
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit currentIk less 400 A)
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 50 A
at 500 V gL/gG 35 A
at 690 V gL/gG 35 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Circuit breaker size S00 for motor protection, CLASS 10 A-release3.5...5 A
N release 65 A 1 NO+1 NC transverse Screw terminalStandard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 3.5 - 5
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value5A
operating current
at AC-3 at 400 V rated value 5 A
operating power at AC-3
at 230 V rated value 1100 W
at 400 V rated value 1500 W
at 500 V rated value 2200 W
at 690 V rated value 4000 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 3 kA
at 690 V rated value 2 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 3 kA
at AC at 690 V rated value 2 kA
response value current
of instantaneous short-circuit trip unit 65 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value5A
at 600 V rated value5 A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 0.166 hp
at 230 V rated value 0.5 hp
for three-phase AC motor
at 200/208 V rated value 1 hp
at 220/230 V rated value 1 hp
at 460/480 V rated value 3 hp
at 575/600 V rated value 3 hp
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switchrequired
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit currentIk less 400 A)
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 50 A
at 500 V gL/gG 35 A
at 690 V gL/gG 35 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Las personas que compraron este artículo también vieron
GE Disyuntor GPS1BSAH 2.5-4A
US$223.08
Siemens Disyuntor 3RV2023-4AA10
US$277.79
Schneider Disyuntor EA9A47C10
US$125.00
ABB Disyuntor SH203-C50
US$44.92
CHINT Transformador JBK3-250
US$63.50
ALBRIGHT Contactor SW180-559
US$250.00
Schurter Fusible 3402.0015.22
US$1.38
FUJITSU Relé FTR-B3CA012Z
US$13.46
UniOhm Resistor 0603WAJ0272T5E
US$4.23
Los clientes ven con frecuencia
Carel Válvula de expansión E6VB2ASV00
US$839.00
Mitsubishi Compresor RE277NRAMT
US$389.00
Togami Contactor CLK-25J3
US$79.00
Copeland Compresor ZB76K5E-TFD-260
US$1860.00
SHAKO Cilindro de aire PCC32B175
US$116.18
KONAN Válvula solenoide MVD2-10A-UX-ZN-AC100
US$1923.08
Publicaciones relacionadas recientes
-
12/05/2023
Principios y diferencias de los transmisores de 2, 3 y 4 hilos
Los transmisores de 2, 3 y 4 hilos se refieren a transmisores cuyas salidas son señales analógicas de corriente CC.
-
08/08/2023
Método de cálculo del peso por metro de tubo de cobre para aire acondicionado
Método de cálculo del peso por metro de tubería de cobre para aire acondicionado.
-
07/29/2023
Compresor Scroll Vs. Compresor rotativo para CA
El compresor scrollue inventado en 1905 por el francés Copeland. Creó la compañía Copeland en los Estados Unidos, donde se utilizan principalmente acondicionadores de aire de agua
-
05/11/2022
Reparación de averías en servoaccionamientos Ultra3000
Hemos enumerado las fallas comunes y los métodos de reparación de los servovariadores Ultra3000; si necesita reemplazar el equipo, le brindamos Servoaccionamiento Allen Bradley Rockwell.
-
08/04/2023
Aire acondicionado Mitsubishi vs Panasonic
El verano es tan difícil de pasar que las personas sin aire acondicionado son como peces fuera del agua. Es fundamental elegir un buen aire acondicionado.
-
06/27/2023
Principio de funcionamiento del compresor frigorífico, esquema eléctrico, estructura
El componente principal del refrigerador es el compresor. Si un frigorífico no está equipado con un compresor de buena calidad y tecnología no puede ser un buen frigorífico.
-
01/07/2024
¿Por qué vibra el servomotor?
¿En qué casos vibrará un servomotor? ¿Qué pasa si el servomotor vibra? ¿Cómo podemos solucionar los problemas causados por la vibración? Este artículo explicará varias razones para esto.
-
03/10/2024
Todo lo que debe saber sobre el embrague magnético del compresor de CA del coche
Este artículo presenta los componentes del embrague magnético del compresor y su principio de funcionamiento, así como varios parámetros importantes. Además, también le brindamos algunas experiencias sobre cómo lidiar con la quema de los embragues del compresor del aire acondicionado.
-
11/18/2023
Transmisores Rosemount Series 1151, 2088, 2051, 3051CA, 3051S y sus diferencias
El transmisor de presión Rosemount es un tipo de transmisor de presión general. Está fabricado según la ley de inducción electromagnética y la norma JB/T9248-1999.
-
02/17/2024
Método de cableado del relé PTC de nevera
El relé PTC (coeficiente de temperatura positivo) está conectado directamente en serie con el devanado secundario (devanado de arranque) y en paralelo con el devanado principal del motor.