Mejores selecciones
1/3
Siemens Disyuntor 3RV1011-1EA10
$ 324 .91
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Parámetro
| Tipo | 3RV1 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 4 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 2.8...4 A |
| Adecuado para motores de inducción con P | 1.5 kW |
| Liberaciones instantáneas de sobrecorriente | 52 A |
| Short-circuit breaking capacidad | 100 kA |
| Peso approx. | 0.281 kg |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S00 for motor protection, CLASS 10 A-release2.8...4 A
N release 52 A Screw terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 2.8 - 4
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value 4 A
operating current
at AC-3 at 400 V rated value 4 A
operating power at AC-3
at 230 V rated value 750 W
at 400 V rated value 1500 W
at 500 V rated value 2200 W
at 690 V rated value 3000 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 3 kA
at 690 V rated value 2 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 3 kA
at AC at 690 V rated value 2 kA
response value current
of instantaneous short-circuit trip unit 52 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 4 A
at 600 V rated value 4 A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 0.125 hp
at 230 V rated value 0.33 hp
for three-phase AC motor
at 200/208 V rated value 0.75 hp
at 220/230 V rated value 0.75 hp
at 460/480 V rated value 2 hp
at 575/600 V rated value 3 hp
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 40 A
at 500 V gL/gG 35 A
at 690 V gL/gG 35 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Circuit breaker size S00 for motor protection, CLASS 10 A-release2.8...4 A
N release 52 A Screw terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 2.8 - 4
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value 4 A
operating current
at AC-3 at 400 V rated value 4 A
operating power at AC-3
at 230 V rated value 750 W
at 400 V rated value 1500 W
at 500 V rated value 2200 W
at 690 V rated value 3000 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 3 kA
at 690 V rated value 2 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 3 kA
at AC at 690 V rated value 2 kA
response value current
of instantaneous short-circuit trip unit 52 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 4 A
at 600 V rated value 4 A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 0.125 hp
at 230 V rated value 0.33 hp
for three-phase AC motor
at 200/208 V rated value 0.75 hp
at 220/230 V rated value 0.75 hp
at 460/480 V rated value 2 hp
at 575/600 V rated value 3 hp
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 40 A
at 500 V gL/gG 35 A
at 690 V gL/gG 35 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo consultar la fecha de producción o fecha de vencimiento de un producto?
Responder: Para comprobar la fecha de producción o la fecha de caducidad de un producto, puede consultar el embalaje o las etiquetas del producto. Proporcionamos información clara y precisa sobre la fecha de fabricación y la fecha de vencimiento, lo que le permite tomar decisiones de compra informadas. Si necesita más ayuda, nuestro equipo de atención al cliente siempre está listo para ayudar.
- Consulta: ¿El producto tiene garantía de calidad?
Responder: ¡Absolutamente! Estamos orgullosos de ofrecer productos de alta calidad. Cada producto se somete a rigurosos controles de calidad para garantizar la excelencia y la satisfacción del cliente. Respaldamos la calidad de nuestros productos.
- Consulta: ¿Cómo puedo enviar comentarios o reseñar un producto?
Responder: Puede proporcionar comentarios o reseñar un producto accediendo a la página del producto y haciendo clic en la opción "Escribir una reseña" o "Dejar comentarios". Comparta su experiencia y opiniones para ayudar a otros compradores a tomar decisiones informadas.
Comentarios
- L
Lucia
14/09/2024
Siemens Disyuntor 3RV1011-1EA10El Siemens 3RV1011-1EA10 es un disyuntor ideal para proteger mis circuitos de sobrecargas y cortocircuitos. Su alta capacidad de corte de 10 kA me da la tranquilidad de que mis equipos estarán seguros en caso de un fallo eléctrico. Además, su diseño compacto lo hace perfecto para mi panel eléctrico.ÚtilNo ayuda - A
Andrés
07/08/2024
Siemens Disyuntor 3RV1011-1EA10El Siemens 3RV1011-1EA10 es un disyuntor de alta calidad que cumple con todas mis expectativas. Su construcción robusta y sus conexiones de terminales de tornillo garantizan una larga vida útil y una fácil conexión. Es una excelente inversión para proteger mis equipos eléctricos.ÚtilNo ayuda - M
Miriam
18/07/2024
Siemens Disyuntor 3RV1011-1EA10Estoy muy satisfecho con el rendimiento del Siemens 3RV1011-1EA10. Su curva de disparo C asegura una protección rápida y precisa contra sobrecargas, mientras que su montaje en riel DIN facilita su instalación y mantenimiento. Lo recomiendo para cualquier aplicación industrial o comercial.ÚtilNo ayuda - E
Emilio
18/08/2023
Siemens Disyuntor 3RV1011-1EA10¡Los mejores precios!ÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV1011-1EA10¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV1011-1EA10
$ 324 .91
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Siemens Disyuntor 3RV2011-1BA15
US$313.83
Siemens Disyuntor 3VL5763-2AE36-0AA0
US$2656.25
Siemens Disyuntor 3RV1041-4KA15
US$1030.73
Mitsubishi Disyuntor NF30-FAU 2P 10A
US$42.97
TRIAD Transformador F56-045-C2
US$13.46
SPRECHER+SCHUH Contactor CA7-60-00
US$976.56
Siba Fusible 7006584
US$5.78
Pilz Relé 774053
US$455.00
UniOhm Resistor 0805W8F300JT5E
US$8.46
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Banner Sensor T18-2VNFF200-9M
US$44.23
YUTIEN Válvula de desbordamiento EBG-06
US$256.15
Yuci Bomba de paletas PFED-5141090/56-5-D-TB/PF
Contacta con nosotros
LUT Cojinete UC210
US$2.69
SUNON Ventilador PMD1206PMB4-A.(2).GN
Contacta con nosotros
ASCO Válvula solenoide L12BB652B000061
Contacta con nosotros
AirTAC Cilindro de aire ACP20X75S
US$61.92