Parámetro
| Tipo | 3RV1 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 3.2 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 2.2...3.2 A |
| Adecuado para motores de inducción con P | 1.1 kW |
| Liberaciones instantáneas de sobrecorriente | 42 A |
| Short-circuit breaking capacidad | 100 kA |
| Peso approx. | 0.283 kg |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S00 for motor protection, CLASS 10 A-release2.2...3.2 A
N release 42 A Screw terminal Standard switchingcapacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 2.2 - 3.2
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value3.2A
operating current
at AC-3 at 400 V rated value 3.2 A
operating power at AC-3
at 230 V rated value 550 W
at 400 V rated value1100 W
at 500 V rated value1500 W
at 690 V rated value2200 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 3 kA
at 690 V rated value 2 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 3 kA
at AC at 690 V rated value 2 kA
response value current
of instantaneous short-circuit trip unit 42 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value3.2A
at 600 V rated value3.2 A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 0.1 hp
at 230 V rated value 0.25 hp
for three-phase AC motor
at 200/208 V rated value 0.5 hp
at 220/230 V rated value 0.75 hp
at 460/480 V rated value 1.5 hp
at 575/600 V rated value2 hp
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 40 A
at 500 V gL/gG 35 A
at 690 V gL/gG 35 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Circuit breaker size S00 for motor protection, CLASS 10 A-release2.2...3.2 A
N release 42 A Screw terminal Standard switchingcapacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 2.2 - 3.2
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value3.2A
operating current
at AC-3 at 400 V rated value 3.2 A
operating power at AC-3
at 230 V rated value 550 W
at 400 V rated value1100 W
at 500 V rated value1500 W
at 690 V rated value2200 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 3 kA
at 690 V rated value 2 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 3 kA
at AC at 690 V rated value 2 kA
response value current
of instantaneous short-circuit trip unit 42 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value3.2A
at 600 V rated value3.2 A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 0.1 hp
at 230 V rated value 0.25 hp
for three-phase AC motor
at 200/208 V rated value 0.5 hp
at 220/230 V rated value 0.75 hp
at 460/480 V rated value 1.5 hp
at 575/600 V rated value2 hp
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 40 A
at 500 V gL/gG 35 A
at 690 V gL/gG 35 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo cambiar mi dirección de correo electrónico asociada a mi cuenta?
Responder: Para cambiar la dirección de correo electrónico asociada a su cuenta, comuníquese con nuestro equipo de servicio al cliente y proporcióneles la información de verificación necesaria. Ellos le ayudarán a actualizar su dirección de correo electrónico.
- Consulta: ¿Puedo guardar artículos en mi carrito para comprarlos más tarde?
Responder: Sí, puede guardar artículos en su carrito para futuras compras. Al agregar artículos a su lista de deseos o guardarlos en su cuenta, podrá acceder fácilmente a ellos y comprarlos más tarde sin necesidad de buscarlos nuevamente.
- Consulta: ¿Cómo puedo ver la calificación promedio y las reseñas de los usuarios de un producto?
Responder: En la página de detalles del producto, puede ver la calificación promedio y las reseñas de los usuarios. Alentamos a los usuarios a compartir sus experiencias de compra y comentarios sobre los productos, para que pueda comprender mejor las opiniones y sugerencias de otros compradores.
Comentarios
- M
Mauricio
08/09/2024
Siemens Disyuntor 3RV1011-1DA10Como técnico electricista, recomiendo el disyuntor Siemens 3RV1011-1DA10 para instalaciones comerciales e industriales. Su curva de disparo C asegura una respuesta rápida a sobrecargas, protegiendo los equipos sensibles. Además, sus conexiones mediante bornes roscados garantizan una conexión segura y confiable.ÚtilNo ayuda - R
Rosa
22/07/2024
Siemens Disyuntor 3RV1011-1DA10El disyuntor Siemens 3RV1011-1DA10 es ideal para proteger los circuitos de mi hogar. Su alta capacidad de corte de 10 kA me da la seguridad de que mis electrodomésticos estarán protegidos contra cortocircuitos. Además, su montaje sobre riel DIN facilita la instalación y su tamaño compacto me permite ahorrar espacio en mi tablero eléctrico.ÚtilNo ayuda - A
Adrián
22/07/2024
Siemens Disyuntor 3RV1011-1DA10En mi taller de reparación de electrodomésticos, el disyuntor Siemens 3RV1011-1DA10 es una herramienta indispensable. Su tamaño compacto me permite instalarlo en espacios reducidos y su peso ligero facilita su manipulación. Además, la marca Siemens es garantía de calidad y durabilidad, lo que me da la confianza de que mis clientes estarán satisfechos.ÚtilNo ayuda - A
Adriana
11/11/2023
Siemens Disyuntor 3RV1011-1DA10GraciasÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV1011-1DA10¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV1011-1DA10
$ 345 .00
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Honeywell Disyuntor HMS-2C6
US$28.99
Terasaki Disyuntor S225-NF
US$656.15
ABB Disyuntor S201M-C4UC
US$28.13
Eaton Moeller Disyuntor LZMN3-AE400
US$974.26
CHINT Transformador JBK4-2500
US$222.50
Eaton Contactor XTCG012B00DU
US$76.54
FANUC Fusible A03B-0815-K001
US$57.50
IXYS Relé CPC1540GSTR
US$8.08
Siemens Resistor JJY:023423320001
US$2884.62
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
SIEMENS Relé 3UG4621-1AA30
US$1153.46
Copeland Compresor 4MFD-13X-AWY-D
Contacta con nosotros
Bristol Compresor H25A32QDBFK
Contacta con nosotros
SKF Cojinete 7009 CD/P4ADB
US$257.69
ATOS Válvula solenoide DHA-0751/2/M/7
Contacta con nosotros
Sanyo Denki Ventilador 109P0405M901
US$13.23
Bristol Compresor H82J48BABCR
Contacta con nosotros
Tecumseh Compresor AE1390Y-AA1A
US$352.11