Mejores selecciones
Schneider Transformador ABL6TS16G
$ 222 .50
(5) 1
Comentarios
Cantidad
MOQ : 2
Pagos
Main range of product
Phaseo Optimum
product or component type
Safety and isolation transformer
rated power in VA
160 VA
input voltage
230 V AC single phase, terminal(s): N-L1
400 V AC phase to phase, terminal(s): L1-L2
output voltage
115 V AC
secondary winding
Single
protective cover
Without
ambient air temperature for operation
-20...50 Celsius degrees
Complementary input voltage limits
207...253 V
360...440 V
network frequency limits
47...63 Hz
input voltage tolerance
+/- 15 V
efficiency
88 %
power dissipation in W
21.8 W
output sustained overvoltage
6 % (no load, hot state)
voltage drop at rated load
<= 0.7 %
no load losses
9.1 W
short-circuit voltage
0,0665
output protection type
Against overload, protection technology: external
Against overvoltage, protection technology: external
Against short-circuits, protection technology: external
connections - terminals
Screw type terminals for input connection, connection capacity: 5 x 4 mm^2 AWG 11
Screw type terminals for input ground connection, connection capacity: 1 x 4 mm^2 AWG 11
Screw type terminals for output connection, connection capacity: 2 x 4 mm^2 AWG 11
marking
CE
fixing mode
By 4 screws, screw(s) D = 5.8 mm on horizontal panel with derating to 90 %
By 4 screws, screw(s) D = 5.8 mm on vertical panel, operating position: horizontal
By 4 screws, screw(s) D = 5.8 mm on vertical panel, operating position: vertical
operating altitude
3000 m
electrical insulation class
Class B
width
106 mm
height
112 mm
depth
81 mm
product weight
3.2 kg
Environment product certifications
UR
EAC
standards
UL 506
IP degree of protection
IP20
environmental characteristic
EMC conforming to EN 62041
Safety conforming to EN 61558-1
Safety conforming to EN 61558-2-6
protective treatment
TC
ambient air temperature for storage
-40...80 Celsius degrees
overvoltage category
Class I conforming to VDE 0106-1
dielectric strength
Between winding and ground
Between primary and secondary
Phaseo Optimum
product or component type
Safety and isolation transformer
rated power in VA
160 VA
input voltage
230 V AC single phase, terminal(s): N-L1
400 V AC phase to phase, terminal(s): L1-L2
output voltage
115 V AC
secondary winding
Single
protective cover
Without
ambient air temperature for operation
-20...50 Celsius degrees
Complementary input voltage limits
207...253 V
360...440 V
network frequency limits
47...63 Hz
input voltage tolerance
+/- 15 V
efficiency
88 %
power dissipation in W
21.8 W
output sustained overvoltage
6 % (no load, hot state)
voltage drop at rated load
<= 0.7 %
no load losses
9.1 W
short-circuit voltage
0,0665
output protection type
Against overload, protection technology: external
Against overvoltage, protection technology: external
Against short-circuits, protection technology: external
connections - terminals
Screw type terminals for input connection, connection capacity: 5 x 4 mm^2 AWG 11
Screw type terminals for input ground connection, connection capacity: 1 x 4 mm^2 AWG 11
Screw type terminals for output connection, connection capacity: 2 x 4 mm^2 AWG 11
marking
CE
fixing mode
By 4 screws, screw(s) D = 5.8 mm on horizontal panel with derating to 90 %
By 4 screws, screw(s) D = 5.8 mm on vertical panel, operating position: horizontal
By 4 screws, screw(s) D = 5.8 mm on vertical panel, operating position: vertical
operating altitude
3000 m
electrical insulation class
Class B
width
106 mm
height
112 mm
depth
81 mm
product weight
3.2 kg
Environment product certifications
UR
EAC
standards
UL 506
IP degree of protection
IP20
environmental characteristic
EMC conforming to EN 62041
Safety conforming to EN 61558-1
Safety conforming to EN 61558-2-6
protective treatment
TC
ambient air temperature for storage
-40...80 Celsius degrees
overvoltage category
Class I conforming to VDE 0106-1
dielectric strength
Between winding and ground
Between primary and secondary
Las personas que compraron este artículo también vieron
CHINT Transformador NDK(BK)-500
US$96.25
Moeller Contactor DIL00M-10
US$341.54
Fuji Fusible CS5F-800
US$38.46
CELDUC Relé SO849070
US$92.31
Arcol Resistor HS50200RF
US$15.38
Los clientes ven con frecuencia
Carel Válvula de expansión E6VB2ASV00
US$839.00
Mitsubishi Compresor RE277NRAMT
US$389.00
Togami Contactor CLK-25J3
US$79.00
Daikin Válvula de expansión AKZ438
US$175.68
PALL Filtro HC8314FCT39H
US$146.15
Delta PLC Analog I/O module AS08AD-B
US$583.85
Publicaciones relacionadas recientes
-
05/12/2022
Reparación de averías en servoaccionamientos Ultra3000
Hemos enumerado las fallas comunes y los métodos de reparación de los servovariadores Ultra3000; si necesita reemplazar el equipo, le brindamos Servoaccionamiento Allen Bradley Rockwell.
-
11/18/2023
Transmisores Rosemount Series 1151, 2088, 2051, 3051CA, 3051S y sus diferencias
El transmisor de presión Rosemount es un tipo de transmisor de presión general. Está fabricado según la ley de inducción electromagnética y la norma JB/T9248-1999.
-
01/08/2024
¿Por qué vibra el servomotor?
¿En qué casos vibrará un servomotor? ¿Qué pasa si el servomotor vibra? ¿Cómo podemos solucionar los problemas causados por la vibración? Este artículo explicará varias razones para esto.
-
06/27/2023
Principio de funcionamiento del compresor frigorífico, esquema eléctrico, estructura
El componente principal del refrigerador es el compresor. Si un frigorífico no está equipado con un compresor de buena calidad y tecnología no puede ser un buen frigorífico.
-
05/19/2022
17 fabricantes de compresores centrífugos, en el mundo. ¿cuántos conoce?
En la última década, en un contexto de globalización económica y feroz competencia, la industria de fabricación de compresores centrífugos también ha experimentado continuas fusiones, adquisiciones y reorganizaciones.
-
08/08/2023
Método de cálculo del peso por metro de tubo de cobre para aire acondicionado
Método de cálculo del peso por metro de tubería de cobre para aire acondicionado.
-
12/05/2023
Principios y diferencias de los transmisores de 2, 3 y 4 hilos
Los transmisores de 2, 3 y 4 hilos se refieren a transmisores cuyas salidas son señales analógicas de corriente CC.
-
08/04/2023
Aire acondicionado Mitsubishi vs Panasonic
El verano es tan difícil de pasar que las personas sin aire acondicionado son como peces fuera del agua. Es fundamental elegir un buen aire acondicionado.
-
07/29/2023
Compresor Scroll Vs. Compresor rotativo para CA
El compresor scrollue inventado en 1905 por el francés Copeland. Creó la compañía Copeland en los Estados Unidos, donde se utilizan principalmente acondicionadores de aire de agua
-
02/17/2024
Método de cableado del relé PTC de nevera
El relé PTC (coeficiente de temperatura positivo) está conectado directamente en serie con el devanado secundario (devanado de arranque) y en paralelo con el devanado principal del motor.