Mejores selecciones
1/1
Dwyer Caudalímetro UFC-123
No hay precio en este momento, puede solicitar una cotización
Service:Homogeneous liquids that do not contain more than 3% of air bubbles or particulate and capable of ultrasonic wave propagation.
Inputs:TNC cable from sensors.
Range:0.33 to 33 ft/s (0.1 to 10 m/s) .
Display:240 x 64 pixel graphic display, high contrast black on white with backlight. Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5" W x 1.3" H (5 x 33.02 mm).
Accuracy:±0.5 to ±2% of flow reading of flow rate > 0.03 ft/s (0.01 m/s) and pipe OD > 3.0 in (75 mm); ±3% of flow reading for flow rate > 0.03 ft/s (0.01 m/s) and pipe OD 0.5 to 3 in (13 to 75 mm); ±6% of flow reading for flow rate < 0.03 ft/s (0.01 m/s).
Power Requirements:86 to 264 VAC (50 to 60 Hz) or 24 VAC/VDC (1 A max.).
Power Consumption:10.5 W.
Temperature Limits:Transducer: -4 to 275°F (-20 to 135°C); Controller: -4 to 122°F (-20 to 50°C).
Outputs:Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 O max; Alarm: 2 opto-isolated MOSFET NO relays, 48 V at 500 mA, maximum 200 Hz; Pulsed: 1 opto-isolated MOSFET relay, 48 V at 500 mA, 1 to 250 pps; Pulse width: 2 to 500 ms (selectable).
Serial Communications:USB.Materials:Plastic ABS and aluminum.
Repeatability:±0.5% of measured value or 0.03 ft/s (0.01 m/s).
Electrical Connections:Removeable screw in type terminal block.
Mounting:Wall mounted using 3 type M4 screws.
Turbidity:<3% by volume of particulate content.
Permissible Air Content:<3% by volume.
Response Time:<500 ms.
Weight:Unit not including accessories: 2.80 lb (1.26 kg); Unit including accessories: 9.92 lb (4.5 kg).
Inputs:TNC cable from sensors.
Range:0.33 to 33 ft/s (0.1 to 10 m/s) .
Display:240 x 64 pixel graphic display, high contrast black on white with backlight. Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5" W x 1.3" H (5 x 33.02 mm).
Accuracy:±0.5 to ±2% of flow reading of flow rate > 0.03 ft/s (0.01 m/s) and pipe OD > 3.0 in (75 mm); ±3% of flow reading for flow rate > 0.03 ft/s (0.01 m/s) and pipe OD 0.5 to 3 in (13 to 75 mm); ±6% of flow reading for flow rate < 0.03 ft/s (0.01 m/s).
Power Requirements:86 to 264 VAC (50 to 60 Hz) or 24 VAC/VDC (1 A max.).
Power Consumption:10.5 W.
Temperature Limits:Transducer: -4 to 275°F (-20 to 135°C); Controller: -4 to 122°F (-20 to 50°C).
Outputs:Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 O max; Alarm: 2 opto-isolated MOSFET NO relays, 48 V at 500 mA, maximum 200 Hz; Pulsed: 1 opto-isolated MOSFET relay, 48 V at 500 mA, 1 to 250 pps; Pulse width: 2 to 500 ms (selectable).
Serial Communications:USB.Materials:Plastic ABS and aluminum.
Repeatability:±0.5% of measured value or 0.03 ft/s (0.01 m/s).
Electrical Connections:Removeable screw in type terminal block.
Mounting:Wall mounted using 3 type M4 screws.
Turbidity:<3% by volume of particulate content.
Permissible Air Content:<3% by volume.
Response Time:<500 ms.
Weight:Unit not including accessories: 2.80 lb (1.26 kg); Unit including accessories: 9.92 lb (4.5 kg).
Hacer preguntas
(0/1,200)
- Consulta: ¿Conseguimos descuentos adicionales por compras al mayor?
Responder: Absolutamente. Ofrecemos descuentos especiales para compras al por mayor. Cuanto más compre, más ahorrará. Comuníquese con nuestro equipo de ventas o visite nuestro sitio web para obtener más información sobre precios y descuentos al por mayor.
- Consulta: ¿Qué debo hacer si recibo el artículo incorrecto?
Responder: Si recibe el artículo incorrecto, comuníquese con nuestro equipo de servicio al cliente de inmediato. Bríndeles los detalles del pedido y una descripción del artículo incorrecto recibido. Rectificaremos el problema organizando una devolución y enviándole el artículo correcto.
- Consulta: ¿Cómo puedo ofrecer sugerencias para mejorar sus servicios?
Responder: Valoramos sus comentarios y sugerencias para mejorar nuestros servicios. Puede proporcionar sugerencias comunicándose con nuestro equipo de atención al cliente o utilizando el formulario de comentarios en nuestro sitio web. Apreciamos sus comentarios y nos esforzamos por mejorar nuestras ofertas en función de las sugerencias de los clientes.
Comentarios
- U
Usuario anónimo
25/11/2022
Dwyer Caudalímetro UFC-123¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Dwyer Caudalímetro UFC-123
No hay precio en este momento, puede solicitar una cotización
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Balluff Sensor BES00TM
US$42.31
Nais Relé HC2-HPL-DC24V-F
US$49.23
Contrinex Sensor DW-AD-605-M8-120
US$46.15
ARK Válvula solenoide KVP642-DC24V
US$715.00
AirTAC Cilindro de aire SE80X110
US$89.23
TOWA SEIDEN Interruptor CS-A3SA-025
US$718.78
PIZZATO Interruptor FL 676-M2
US$269.23
Mitsubishi Compresor ANB52FKKMT
US$1478.87

