Mejores selecciones
1/1
Dwyer Caudalímetro UFB-222
No hay precio en este momento, puede solicitar una cotización
Service:Homogeneous liquids that do not contain more than 3% of air bubbles or particulate and capable of ultrasonic wave propagation.
Inputs:TNC cable from sensors.
Range:0.33 to 33 ft/s (0.1 to 10 m/s).
Display:240 x 64 pixel graphic display, high contrast black on white with backlight; Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5" W x 1.3" H (5 x 33.02 mm).
Accuracy:±0.5 to ±2% of flow reading of flow rate > 0.03 ft/s (0.01 m/s) and pipe OD > 3.0 in (75 mm); ±3% of flow reading for flow rate > 0.03 ft/s (0.01 m/s) and pipe OD 0.5 to 3 in (13 to 75 mm); ±6% of flow reading for flow rate < 0.03 ft/s (0.01 m/s).
Power Requirements:86 to 264 VAC (50 to 60 Hz) or 24 VAC/VDC (1 A max).
Power Consumption:10.5 W.
Temperature Limits:Transducer: -4 to 275°F (-20 to 135°C); Controller: -4 to 122°F (-20 to 50°C).
Outputs:Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 O max; Alarm: 2 opto-isolated MOSFET NO relays, 48 V at 500 mA, maximum 200 Hz; Pulsed: 1 opto-isolated MOSFET relay, 48 V at 500 mA, 1 to 250 pps; Pulse width: 2 to 500 ms (selectable).
Enclosure Rating:IP65 when using TNC connector; Transducers IP54.
Materials:Plastic ABS and aluminum.
Repeatability:±0.5 % of measured value or 0.03 ft/s (0.01 m/s).
Electrical Connections:Removeable screw-in type terminal block.
Mounting:Wall mounted using 3 type M4 screws.
Turbidity:<3 % by volume of particulate content.Permissible Air Content:<3% by volume.
Response Time:<500 ms.
Weight:>Unit not including accessories: 2.80 lb (1.26 kg);
Unit including accessories: 9.92 lb (4.5 kg).
Inputs:TNC cable from sensors.
Range:0.33 to 33 ft/s (0.1 to 10 m/s).
Display:240 x 64 pixel graphic display, high contrast black on white with backlight; Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5" W x 1.3" H (5 x 33.02 mm).
Accuracy:±0.5 to ±2% of flow reading of flow rate > 0.03 ft/s (0.01 m/s) and pipe OD > 3.0 in (75 mm); ±3% of flow reading for flow rate > 0.03 ft/s (0.01 m/s) and pipe OD 0.5 to 3 in (13 to 75 mm); ±6% of flow reading for flow rate < 0.03 ft/s (0.01 m/s).
Power Requirements:86 to 264 VAC (50 to 60 Hz) or 24 VAC/VDC (1 A max).
Power Consumption:10.5 W.
Temperature Limits:Transducer: -4 to 275°F (-20 to 135°C); Controller: -4 to 122°F (-20 to 50°C).
Outputs:Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 O max; Alarm: 2 opto-isolated MOSFET NO relays, 48 V at 500 mA, maximum 200 Hz; Pulsed: 1 opto-isolated MOSFET relay, 48 V at 500 mA, 1 to 250 pps; Pulse width: 2 to 500 ms (selectable).
Enclosure Rating:IP65 when using TNC connector; Transducers IP54.
Materials:Plastic ABS and aluminum.
Repeatability:±0.5 % of measured value or 0.03 ft/s (0.01 m/s).
Electrical Connections:Removeable screw-in type terminal block.
Mounting:Wall mounted using 3 type M4 screws.
Turbidity:<3 % by volume of particulate content.Permissible Air Content:<3% by volume.
Response Time:<500 ms.
Weight:>Unit not including accessories: 2.80 lb (1.26 kg);
Unit including accessories: 9.92 lb (4.5 kg).
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo cancelar o modificar un pedido?
Responder: Si necesita cancelar o modificar un pedido, comuníquese con nuestro equipo de atención al cliente lo antes posible. Haremos todo lo posible para satisfacer sus necesidades y brindarle asistencia según el estado y la viabilidad del pedido.
- Consulta: ¿Cómo unirse a una comunidad o foro para discutir y compartir experiencias de compra?
Responder: Contamos con una comunidad vibrante y un foro donde puede participar en debates, compartir sus experiencias de compra y conectarse con otros compradores. Simplemente regístrese en nuestro sitio web y comience a interactuar con otros miembros de la comunidad.
- Consulta: ¿Puedo guardar mi información de pago para realizar un pago más rápido?
Responder: Priorizamos la seguridad de su información de pago y no almacenamos detalles de pago confidenciales en nuestros servidores. Sin embargo, es posible que tenga la opción de guardar de forma segura su información de pago con procesadores de pago externos confiables para realizar pagos más rápido en pedidos futuros.
Comentarios
- U
Usuario anónimo
25/11/2022
Dwyer Caudalímetro UFB-222¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Dwyer Caudalímetro UFB-222
No hay precio en este momento, puede solicitar una cotización
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Yaskawa Servo Motor SGMPH-01B1A21
Contacta con nosotros
CKD Cilindro de aire LCS-12-30
US$357.69
SKF Cojinete 23030 CC/C4W33
US$1393.46
Hisense Aire acondicionado KFR-35GW-K200X-A1
US$1380.00
Copeland Compresor ZP182KCE-TE5-551
Contacta con nosotros
Sanyo Denki Servo Motor P30B04010DBS00
Contacta con nosotros
Copeland Compresor ZPD42KSE-TFD-426
Contacta con nosotros
Ebmpapst Ventilador 4314 NM
Contacta con nosotros