Service:Homogeneous liquids that do not contain air bubbles capable of ultrasonic wave propagation.
Inputs:Lemo connector cable from sensors.
Range:0.33 to 65.62 ft/s (0.1 to 20 m/s).
Display:240 x 64 pixel graphic display, high contrast black on white with backlight; Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5.2" W x 1.5" H (132.1 x 38.1 mm).
Accuracy:± 0.5 to 2% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and Pipe ID > 3 in (75 mm). ± 3% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and Pipe ID in range 0.5 to 3 in (13 to 75 mm). ± 6% of flow reading for flow rate < 0.66 ft/s (0.2 m/s).
Power Requirements:9 to 24 VDC; (1) 5-Cell NiMH battery, internal, factory replaceable (continuous operation time: 20 hours with back light and output off); (recharging time: 6.5 hours, power adapter used).
Power Consumption:10.5 W.
Power Adapter:110/240 VAC adapter; UK,US, European adapters included.
Temperature Limits:-4 to 275°F (-20 to 135°C).
Outputs:Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 O max; Pulse: 1 opto-isolated MOSFET relay, 150 mA max, 500 pps max, 200 Hz max.
Serial Communications:USB; RS-232.
Enclosure Rating:Transducers: IP51; Carrying Case: IP67; Converter: IP54.
Materials:Flame retardant injection molded ABS plastic.
Repeatability:±0.5 % of measured value or ±0.066 ft/s (0.02 m/s).
Electrical Connections:Multi-pin Lemo plugs.
Turbidity:<3% by volume of particulate content.
Permissible Air Content:<3% by volume.
Response Time:<500 ms.
Weight:Unit without accessories: 2.30 lb (1.06 kg); Unit with accessories in carrying case: 14.40 lb (6.52 kg).
Inputs:Lemo connector cable from sensors.
Range:0.33 to 65.62 ft/s (0.1 to 20 m/s).
Display:240 x 64 pixel graphic display, high contrast black on white with backlight; Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5.2" W x 1.5" H (132.1 x 38.1 mm).
Accuracy:± 0.5 to 2% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and Pipe ID > 3 in (75 mm). ± 3% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and Pipe ID in range 0.5 to 3 in (13 to 75 mm). ± 6% of flow reading for flow rate < 0.66 ft/s (0.2 m/s).
Power Requirements:9 to 24 VDC; (1) 5-Cell NiMH battery, internal, factory replaceable (continuous operation time: 20 hours with back light and output off); (recharging time: 6.5 hours, power adapter used).
Power Consumption:10.5 W.
Power Adapter:110/240 VAC adapter; UK,US, European adapters included.
Temperature Limits:-4 to 275°F (-20 to 135°C).
Outputs:Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 O max; Pulse: 1 opto-isolated MOSFET relay, 150 mA max, 500 pps max, 200 Hz max.
Serial Communications:USB; RS-232.
Enclosure Rating:Transducers: IP51; Carrying Case: IP67; Converter: IP54.
Materials:Flame retardant injection molded ABS plastic.
Repeatability:±0.5 % of measured value or ±0.066 ft/s (0.02 m/s).
Electrical Connections:Multi-pin Lemo plugs.
Turbidity:<3% by volume of particulate content.
Permissible Air Content:<3% by volume.
Response Time:<500 ms.
Weight:Unit without accessories: 2.30 lb (1.06 kg); Unit with accessories in carrying case: 14.40 lb (6.52 kg).
Hacer preguntas
(0/1,200)
- Consulta: ¿Tiene una tabla de conversión de tallas para clientes internacionales?
Responder: Sí, proporcionamos tablas de conversión de tallas para clientes internacionales en nuestro sitio web. Estas tablas le ayudan a convertir tallas entre diferentes sistemas de medición, lo que garantiza que seleccione la talla adecuada para su región. Por lo general, se pueden encontrar en la descripción del producto o en la página de la guía de tallas.
- Consulta: ¿Tengo que pagar el envío al devolver un producto?
Responder: Compramos un seguro de envío para cada pedido para garantizar la seguridad de los productos durante el transporte. Si los productos se pierden o dañan, comuníquese con nuestro equipo de servicio al cliente de inmediato. Le ayudaremos a resolver el problema y le proporcionaremos una compensación adecuada.
- Consulta: ¿Ofrecen envío gratuito?
Responder: Podemos ofrecer envío gratuito en productos seleccionados o como parte de campañas promocionales. La disponibilidad de envío gratuito y las condiciones asociadas con él se mencionarán en la página del producto o durante el proceso de pago.
Comentarios
- U
Usuario anónimo
25/11/2022
Dwyer Caudalímetro PUF-1001¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Dwyer Caudalímetro PUF-1001
No hay precio en este momento, puede solicitar una cotización
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Sanyo Denki Ventilador 9RA0824M4001
US$18.41
Panasonic Relé ALZN5B24
US$3.48
Yeoshe Bomba de paletas IVP31-30-10-F-L-86AB-10
Contacta con nosotros
Hitachi Compresor ASD113RKQA6JT6
US$218.70
Carel Válvula de expansión E2V35SWF50
Contacta con nosotros
ULVAC Bomba de Vacío PMB600D-MF9A1S7I4B1
Contacta con nosotros
ANSON Bomba de paletas IVPQ43-75-38-L-R-11CC-10
Contacta con nosotros
SHAKO Cilindro de aire JQ40B25-H-M
Contacta con nosotros
SMC Válvula proporcional ITV2030-312CN2
Contacta con nosotros