Mejores selecciones
1/1
Dwyer Caudalímetro PUB-20
No hay precio en este momento, puede solicitar una cotización
Service:Homogeneous liquids that do not contain air bubbles capable of ultrasonic wave propagation.
Inputs:Lemo connector cable from sensors.
Range:0.33 to 65.62 ft/s (0.1 to 20 m/s).
Display:240 x 64 pixel graphic display, high contrast black on white with backlight; Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5.2" W x 1.5" H.
Accuracy:±0.5 to 2% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and pipe ID > 2.95" (75 mm); ±3% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and pipe ID in range 0.512 to 2.95" (13 to 75 mm); ±6% of flow reading for flow rate < 0.66 ft/s (0.2 m/s).
Power Requirements:9 to 24 VDC, (1) 5-Cell NiMH battery, internal, factory replaceable (continuous operation time: 20 hours with back-light and output off) (recharging time: 6.5 hours, power adapter used).
Power Consumption:10.5 W.
Power Adapter:110/240 VAC adapter. UK, US, European adapters included.
Temperature Limits:-4 to 275°F (-20 to 135°C).
Outputs:Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 Ω max;
Pulse: 1 opto-isolated MOSFET relay, 150 mA max, 500 pps max, 200 Hz max.
Enclosure Rating:Converter: IP54; Transducers: IP51.
Materials:Flame retardant injection molded ABS plastic.
Repeatability:±0.5 % of measured value or ±0.066 ft/s (0.02 m/s).
Electrical Connections:Multi-pin Lemo plugs.
Turbidity:< 3% by volume of particulate content.
Permissible Air Content:< 3% by volume.
Response Time:< 500 ms.
Weight:Unit without accessories: 2.3 lb (1.06 kg); Unit with accessories in carrying case: 13.23 lb (6.0 kg).
Inputs:Lemo connector cable from sensors.
Range:0.33 to 65.62 ft/s (0.1 to 20 m/s).
Display:240 x 64 pixel graphic display, high contrast black on white with backlight; Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5.2" W x 1.5" H.
Accuracy:±0.5 to 2% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and pipe ID > 2.95" (75 mm); ±3% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and pipe ID in range 0.512 to 2.95" (13 to 75 mm); ±6% of flow reading for flow rate < 0.66 ft/s (0.2 m/s).
Power Requirements:9 to 24 VDC, (1) 5-Cell NiMH battery, internal, factory replaceable (continuous operation time: 20 hours with back-light and output off) (recharging time: 6.5 hours, power adapter used).
Power Consumption:10.5 W.
Power Adapter:110/240 VAC adapter. UK, US, European adapters included.
Temperature Limits:-4 to 275°F (-20 to 135°C).
Outputs:Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 Ω max;
Pulse: 1 opto-isolated MOSFET relay, 150 mA max, 500 pps max, 200 Hz max.
Enclosure Rating:Converter: IP54; Transducers: IP51.
Materials:Flame retardant injection molded ABS plastic.
Repeatability:±0.5 % of measured value or ±0.066 ft/s (0.02 m/s).
Electrical Connections:Multi-pin Lemo plugs.
Turbidity:< 3% by volume of particulate content.
Permissible Air Content:< 3% by volume.
Response Time:< 500 ms.
Weight:Unit without accessories: 2.3 lb (1.06 kg); Unit with accessories in carrying case: 13.23 lb (6.0 kg).
Hacer preguntas
(0/1,200)
- Consulta: ¿Qué debo hacer si recibo un artículo dañado o defectuoso?
Responder: Si recibe un artículo dañado o defectuoso, comuníquese con nuestro equipo de atención al cliente de inmediato. Bríndeles los detalles necesarios y, si es posible, incluya fotografías de los daños. Le ayudaremos a resolver el problema ofreciéndole un reemplazo, un reembolso o una solución adecuada.
- Consulta: ¿Cómo puedo ver el estado y el historial de mis pedidos?
Responder: Puede iniciar sesión en su cuenta, acceder a la página de pedidos y ver el estado y el historial de sus pedidos. Actualizaremos el estado del pedido con prontitud y proporcionaremos información detallada del pedido para su comodidad al realizar consultas y seguimiento.
- Consulta: ¿Qué debo hacer si recibo el artículo incorrecto?
Responder: Si recibe el artículo incorrecto, comuníquese con nuestro equipo de servicio al cliente de inmediato. Bríndeles los detalles del pedido y una descripción del artículo incorrecto recibido. Rectificaremos el problema organizando una devolución y enviándole el artículo correcto.
Comentarios
- U
Usuario anónimo
25/11/2022
Dwyer Caudalímetro PUB-20¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Dwyer Caudalímetro PUB-20
No hay precio en este momento, puede solicitar una cotización
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
HENGSTLER Codificador RI58-O/2048ES.41RA
Contacta con nosotros
Delta Ventilador AHB1748GH-R00
Contacta con nosotros
CKD Válvula solenoide 4F510-10
US$307.69
CKD Cilindro de aire SRL3-00-50B-1100
Contacta con nosotros
MITSUBOSHI Belt S3M-888-8
US$14.62
MURATA Condensador GRM32EB31E226ME15L
Contacta con nosotros
Copeland Compresor ZH40KCE-TW7-512
Contacta con nosotros
Bristol Compresor H71J233DBVK
Contacta con nosotros