Chint Disyuntor NM8SL-250S/4C
No hay precio en este momento, puede solicitar una cotización
¡El Chint Circuit Breaker es de alta calidad!
¡El rated limit breaking capacity (kA) Icu AC50Hz 400V 50
¡El rated running breaking capacity (kA) Ics AC50Hz 400V 50
¡El minimum value of the rated residual switching-on and switching-off capacity I△m is 25%Icu. Twelve point five
Use category a.
Total life expectancy with load and no load 1500/8500/10000
Tripper type intelligent
¡El residual operating current (adjustable in the fourth gear) I △ n (a) x1: 0.05/0.1/0.2/0.5; X2:0.1/0.3/0.5/1
Breaking time (adjustable in third gear) Total breaking time (s) T1: 0.3/0.5/1
Weight (kg) 3P/4P 2.6/4
NM8 or NM8S plastic casing circuit breakers are NM8L and NM8SL residual current operated circuit breakers
after being assembled with residual current protection modules conveniently. NM8L and NM8SL series residual
current operated circuit breakers are mainly used in circuits with AC 50Hz, rated voltage up to 400V and
rated current up to 630A A.. Its main function is to provide indirect contact protection for fatal personal
electric shock, and at the same time, it can also be used to prevent electrical fire caused by ground fault
current. It can be used to protect the overload, short circuit and undervoltage of the line, and can also be
used for infrequent switching of the line.
NM8L: Thermomagnetic Residual Current Action Circuit Breaker
NM8SL: Intelligent Residual Current Action Circuit Breaker
Shell level 100A 250A 630A
¡El rated current (a) is 16, 20, 25, 32, 4050, 63, 80, 100, 125, 160, 180, 200, 225, 250, 315, 350, 400, 500, 630
Note: the maximum value of thermomagnetic residual current operated circuit breaker is 500A A.
3 means 3 poles
4 means 4 poles
4A indicates that the N pole is not equipped with an overcurrent release element, and the N pole is always on;
4B indicates that the N-pole is not equipped with an overcurrent release element, and the N-pole and the other
three poles are combined and divided together (the N-pole is combined first and then divided)
4C indicates that the N pole is equipped with an overcurrent trip element, and the N pole is closed and divided
together with the other three poles (the N pole is closed first and then divided), and the operating current is 1.0In;;
4D indicates that the N pole is equipped with an overcurrent tripping element, and the N pole is always on, and the
operating current is 1.0In;;
M: No code for motor protection: power distribution protection
Normal working conditions and installation conditions
¡El altitude of the product installation site is 2000m and below;
¡El external magnetic field of the installation site of residual current operated circuit breaker shall not
exceed 5 times of the earth magnetic field in any direction;
¡El action value of the intelligent release is not affected by temperature fluctuation. However, the maximum
allowable current of residual current operated circuit breaker is still the same as that of circuit breaker
Environmental temperature.
Damp-heat: the relative humidity of the atmosphere should not exceed 50% when the ambient air temperature is
+40℃, and it can be higher at lower temperature. ¡El monthly average maximum relative humidity in the wettest month is
90%, at the same time. ¡El monthly average minimum humidity in this month is +25℃, and the condensation on the
product surface due to temperature change is considered.
Pollution level: the pollution level is level 3
Characteristics
Using splicing modular design, users can install and maintain themselves without affecting the characteristics
of circuit breakers;
With power indication;
¡El residual action current and the breaking time of the residual current can be adjusted, which is convenient
for users to choose;
With residual current action indication and reset button, users can quickly judge the action reason of residual
current action circuit breaker.
In addition, the residual current operated circuit breaker cannot be closed without confirming and eliminating
the leakage fault (the reset button is not pressed);
¡El residual current operated circuit breaker equipped with auxiliary switch can remotely indicate the tripping
of the circuit breaker in case of leakage fault;
High breaking ability and no arcing;
With isolation function and reliable contact indication
Isolation position is in "0" (off) position;
Only when the contact is fully opened can the operating handle indicate the "0" (OFF) position;
Padlocks can only be installed when the contacts are opened;
Rotating the handle will not change the reliability of contact indication;
¡El isolation function shall ensure the mechanical reliability indicated by the contact, no residual current,
and the terminal on the power supply side can withstand high impact voltage;
Isolation function
¡El rated limit breaking capacity (kA) Icu AC50Hz 400V 50
¡El rated running breaking capacity (kA) Ics AC50Hz 400V 50
¡El minimum value of the rated residual switching-on and switching-off capacity I△m is 25%Icu. Twelve point five
Use category a.
Total life expectancy with load and no load 1500/8500/10000
Tripper type intelligent
¡El residual operating current (adjustable in the fourth gear) I △ n (a) x1: 0.05/0.1/0.2/0.5; X2:0.1/0.3/0.5/1
Breaking time (adjustable in third gear) Total breaking time (s) T1: 0.3/0.5/1
Weight (kg) 3P/4P 2.6/4
NM8 or NM8S plastic casing circuit breakers are NM8L and NM8SL residual current operated circuit breakers
after being assembled with residual current protection modules conveniently. NM8L and NM8SL series residual
current operated circuit breakers are mainly used in circuits with AC 50Hz, rated voltage up to 400V and
rated current up to 630A A.. Its main function is to provide indirect contact protection for fatal personal
electric shock, and at the same time, it can also be used to prevent electrical fire caused by ground fault
current. It can be used to protect the overload, short circuit and undervoltage of the line, and can also be
used for infrequent switching of the line.
NM8L: Thermomagnetic Residual Current Action Circuit Breaker
NM8SL: Intelligent Residual Current Action Circuit Breaker
Shell level 100A 250A 630A
¡El rated current (a) is 16, 20, 25, 32, 4050, 63, 80, 100, 125, 160, 180, 200, 225, 250, 315, 350, 400, 500, 630
Note: the maximum value of thermomagnetic residual current operated circuit breaker is 500A A.
3 means 3 poles
4 means 4 poles
4A indicates that the N pole is not equipped with an overcurrent release element, and the N pole is always on;
4B indicates that the N-pole is not equipped with an overcurrent release element, and the N-pole and the other
three poles are combined and divided together (the N-pole is combined first and then divided)
4C indicates that the N pole is equipped with an overcurrent trip element, and the N pole is closed and divided
together with the other three poles (the N pole is closed first and then divided), and the operating current is 1.0In;;
4D indicates that the N pole is equipped with an overcurrent tripping element, and the N pole is always on, and the
operating current is 1.0In;;
M: No code for motor protection: power distribution protection
Normal working conditions and installation conditions
¡El altitude of the product installation site is 2000m and below;
¡El external magnetic field of the installation site of residual current operated circuit breaker shall not
exceed 5 times of the earth magnetic field in any direction;
¡El action value of the intelligent release is not affected by temperature fluctuation. However, the maximum
allowable current of residual current operated circuit breaker is still the same as that of circuit breaker
Environmental temperature.
Damp-heat: the relative humidity of the atmosphere should not exceed 50% when the ambient air temperature is
+40℃, and it can be higher at lower temperature. ¡El monthly average maximum relative humidity in the wettest month is
90%, at the same time. ¡El monthly average minimum humidity in this month is +25℃, and the condensation on the
product surface due to temperature change is considered.
Pollution level: the pollution level is level 3
Characteristics
Using splicing modular design, users can install and maintain themselves without affecting the characteristics
of circuit breakers;
With power indication;
¡El residual action current and the breaking time of the residual current can be adjusted, which is convenient
for users to choose;
With residual current action indication and reset button, users can quickly judge the action reason of residual
current action circuit breaker.
In addition, the residual current operated circuit breaker cannot be closed without confirming and eliminating
the leakage fault (the reset button is not pressed);
¡El residual current operated circuit breaker equipped with auxiliary switch can remotely indicate the tripping
of the circuit breaker in case of leakage fault;
High breaking ability and no arcing;
With isolation function and reliable contact indication
Isolation position is in "0" (off) position;
Only when the contact is fully opened can the operating handle indicate the "0" (OFF) position;
Padlocks can only be installed when the contacts are opened;
Rotating the handle will not change the reliability of contact indication;
¡El isolation function shall ensure the mechanical reliability indicated by the contact, no residual current,
and the terminal on the power supply side can withstand high impact voltage;
Isolation function
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo ver el tamaño y las especificaciones de un producto?
Responder: En la página de detalles del producto, puede encontrar información detallada sobre el tamaño y las especificaciones, incluidas tablas de tamaños, medidas específicas y más, para ayudarlo a seleccionar el producto correcto.
- Consulta: ¿Cómo puedo rastrear mi pedido?
Responder: Una vez que se envíe su pedido, recibirá un correo electrónico de confirmación con información de seguimiento. Puede utilizar esta información para realizar un seguimiento de su pedido a través del sitio web del proveedor de logística.
- Consulta: ¿Ofrecéis servicios de instalación para determinados productos?
Responder: Desafortunadamente, no brindamos directamente servicios de instalación de productos. La disponibilidad de los servicios de instalación generalmente se menciona en la página del producto. Si realmente necesita ayuda con la instalación, comuníquese con nuestro equipo de servicio al cliente para obtener información y arreglos más detallados. Le brindaremos asistencia activamente .
Comentarios
- U
Usuario anónimo
25/11/2022
Chint Disyuntor NM8SL-250S/4C¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Chint Disyuntor NM8SL-250S/4C
No hay precio en este momento, puede solicitar una cotización
Las personas que compraron este artículo también vieron
Siemens Disyuntor 3VT8110-1AA03-0AA0
US$369.00
Block Transformador VB 2,0/1/15
US$13.85
Siemens Contactor 3RT2015-1AV62
US$50.00
Tyco Fusible JK130-090
US$0.77
Lovato Relé ATD
US$8895.69
VISHAY Resistor HRHAFN2000KB
US$70.31
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
NKK Interruptor SW-3003A
US$10.35
TAKEX Sensor NTL50PW
US$557.75
SICK Cortina de luz M40S-062200AR0
Contacta con nosotros
CKD Cilindro de aire SCA2-CB-40B-400/Z
Contacta con nosotros
Bristol Compresor H73C473ABKH
Contacta con nosotros
Ebmpapst Ventilador A6D 800-AS01-02
Contacta con nosotros
CHELIC Pneumatic Equipment Cilindro de aire JDAD63*75-B-SE2
Contacta con nosotros