Mejores selecciones
 1/1
 Chint Disyuntor NB1L-40H
 No hay precio en este momento, puede solicitar una cotización
¡El Chint Circuit Breaker es de alta calidad!
¡El NB1L-40□ residual current operated circuit breaker is suitable for AC 50Hz, rated voltage unipolar
two-wire and bipolar 230V.
Three-pole, three-pole four-wire, four-pole 400V, rated current to 40A line, when personal electric
shock or grid leakage current exceeds
When the value is specified, the residual current operated circuit breaker can quickly cut off the
fault power supply in a very short time to protect people and electricity
¡El safety of equipment can protect the overload or short circuit of the line, and can also be used
for infrequent conversion of the line.
This product is suitable for various places such as industry, commerce, high-rise building and civil residence.
Mechanical electrical life electrical life times (times) 2000 cos ф = 0.85 ~ 0.9 operating frequency In≤25A,
240 times/hour; In > 25a, 120 times/hour
Mechanical life times (times) 20000 operating frequency In≤25A, 240 times/hour; In > 25a, 120 times/hour
NB1L-40 residual current operated circuit breaker is composed of NB1-63 small circuit breaker and residual current
¡El flow tripper is assembled and has the following characteristics:
No auxiliary power supply is needed, which overcomes the disadvantages of poor anti-interference performance of electronic products, power grid voltage
¡El residual current is widened due to the defects of large fluctuation influence and unprotected neutral line disconnection
Scope of protection.
High rated short circuit breaking capacity.
Dynamic control of the test circuit makes it difficult to burn the test resistor.
¡El operating mechanism is designed as an energy storage mechanism, and the product is in moving contact during the closing operation
¡El head stores energy, which makes the moving contact close quickly, and improves the service life and product of the moving contact
¡El ability to break.
Impulse voltage resistance of insulation:
A. the impulse voltage with a peak value of 6000V can be borne between the poles connected together and the neutral pole;
B. Each pole is connected with the neutral pole and can withstand the peak value of 8000V between the metal bracket
Impulse voltage.
Under the action of impulse current with peak current of 200A, residual current operated circuit breaker has
Bearing capacity, and does not cause misoperation.
Elevation: ≤2000m
 
¡El NB1L-40□ residual current operated circuit breaker is suitable for AC 50Hz, rated voltage unipolar
two-wire and bipolar 230V.
Three-pole, three-pole four-wire, four-pole 400V, rated current to 40A line, when personal electric
shock or grid leakage current exceeds
When the value is specified, the residual current operated circuit breaker can quickly cut off the
fault power supply in a very short time to protect people and electricity
¡El safety of equipment can protect the overload or short circuit of the line, and can also be used
for infrequent conversion of the line.
This product is suitable for various places such as industry, commerce, high-rise building and civil residence.
Mechanical electrical life electrical life times (times) 2000 cos ф = 0.85 ~ 0.9 operating frequency In≤25A,
240 times/hour; In > 25a, 120 times/hour
Mechanical life times (times) 20000 operating frequency In≤25A, 240 times/hour; In > 25a, 120 times/hour
NB1L-40 residual current operated circuit breaker is composed of NB1-63 small circuit breaker and residual current
¡El flow tripper is assembled and has the following characteristics:
No auxiliary power supply is needed, which overcomes the disadvantages of poor anti-interference performance of electronic products, power grid voltage
¡El residual current is widened due to the defects of large fluctuation influence and unprotected neutral line disconnection
Scope of protection.
High rated short circuit breaking capacity.
Dynamic control of the test circuit makes it difficult to burn the test resistor.
¡El operating mechanism is designed as an energy storage mechanism, and the product is in moving contact during the closing operation
¡El head stores energy, which makes the moving contact close quickly, and improves the service life and product of the moving contact
¡El ability to break.
Impulse voltage resistance of insulation:
A. the impulse voltage with a peak value of 6000V can be borne between the poles connected together and the neutral pole;
B. Each pole is connected with the neutral pole and can withstand the peak value of 8000V between the metal bracket
Impulse voltage.
Under the action of impulse current with peak current of 200A, residual current operated circuit breaker has
Bearing capacity, and does not cause misoperation.
Elevation: ≤2000m
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo consultar la fecha de producción o fecha de vencimiento de un producto?Responder: Para comprobar la fecha de producción o la fecha de caducidad de un producto, puede consultar el embalaje o las etiquetas del producto. Proporcionamos información clara y precisa sobre la fecha de fabricación y la fecha de vencimiento, lo que le permite tomar decisiones de compra informadas. Si necesita más ayuda, nuestro equipo de atención al cliente siempre está listo para ayudar. 
- Consulta: ¿El producto tiene garantía de calidad?Responder: ¡Absolutamente! Estamos orgullosos de ofrecer productos de alta calidad. Cada producto se somete a rigurosos controles de calidad para garantizar la excelencia y la satisfacción del cliente. Respaldamos la calidad de nuestros productos. 
- Consulta: ¿Cómo puedo enviar comentarios o reseñar un producto?Responder: Puede proporcionar comentarios o reseñar un producto accediendo a la página del producto y haciendo clic en la opción "Escribir una reseña" o "Dejar comentarios". Comparta su experiencia y opiniones para ayudar a otros compradores a tomar decisiones informadas. 
Comentarios
- UUsuario anónimo 25/11/2022 Chint Disyuntor NB1L-40H¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Chint Disyuntor NB1L-40H
No hay precio en este momento, puede solicitar una cotización
Las personas que compraron este artículo también vieron
GE Disyuntor SFKOG 1.6-2.5A
US$176.92
 Schneider Transformador ABL6TS100G
US$321.80
 Siemens Contactor 3RT2326-1BF40
US$173.08
 Schurter Fusible 0034.6014
US$0.81
 TAIAN Relé RHU-10M/0ba 1.1-1.6A/8b2
US$66.54
 Panasonic Resistor EXB-Q16P332J
US$1.15
 Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
 SEALMASTER Cojinete FC-1510
Contacta con nosotros
 NKK Interruptor HS16-2SN
US$48.30
 TAKEX Sensor GMR2RPNN
US$138.00
 Mitsubishi Compresor RB174GNKC
US$340.00
 MGM Motor Eléctrico BM63C4
US$856.00
 Copeland Compresor KAN2-0050-IAA-200
Contacta con nosotros
 Copeland Compresor CS20K6E-TFE-155
Contacta con nosotros
 Copeland Compresor 6DKNF93KE-TSE-799
Contacta con nosotros
 Ebmpapst Ventilador D1G 160
Contacta con nosotros
 ASCO Válvula solenoide WBIS8317A308
Contacta con nosotros
 