Mejores selecciones
1/1
Siemens Disyuntor 3VM1063-4ED32-0AA0
$ 195 .31
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
¡El Siemens Circuit Breaker es de alta calidad!
circuit breaker 3VM1 IEC frame 100 breaking capacity class S
Icu=36kA @ 415V 3-pole, line protection TM210, FTFM, In=63A
overload protection Ir=63A, not adjustable short-circuit protection
Ii=10 x In nut keeper kit
Model
product brand name SENTRON
product designation Molded case circuit breaker
Product version Line protection
design of the overcurrent release TM210
protection function of the overcurrent release LI
number of poles 3
General technical data
Tension assignée d'isolement Ui 690 V
Max. rated operational voltage Ue with AC 50/60Hz 500 V
Max. rated operational voltage Ue with DC 250 V
power loss W / maximum 22 W
Active power loss / for rated value of the current / at
AC / in hot operating state / per pole
7.33 W
mechanical service life (switching cycles) / typical 10 000
Electrical endurance (switching cycles) / at AC-1 / at
380/415 V 50/60 Hz
2 000
Neutral conductors / upgradeable/retrofittable No
ground-fault monitoring version Without
product function
communication function No
other measurement function No
net weight 0.941 kg
Current
Max. rated operational current of the frame size 100 A
Courant permanent assigné Iu 63 A
operational current
at 40 degrees centigrade 63 A
at 45 degrees centigrade 63 A
at 50 degrees centigrade 63 A
at 55 degrees centigrade 62 A
at 60 degrees centigrade 61 A
at 65 degrees centigrade 60 A
at 70 degrees centigrade 58 A
Switching capacity according to IEC 60947
switching capacity class of the circuit breaker S
breaking capacity maximum short-circuit current (Icu)
at 240 V 55 kA
at 415 V 36 kA
at 440 V 20 kA
at 500 V 7 kA
breaking capacity operating short-circuit current (Ics)
at 240 V 18 kA
at 415 V 12 kA
at 440 V 8 kA
at 500 V 2.5 kA
short-circuit current making capacity (Icm)
at 240 V 121 kA
at 415 V 76 kA
at 440 V 40 kA
at 500 V 11.9 kA
design of short-circuit protection For switching capacity values in DC power systems, see the 3VA
Molded Case Circuit Breaker Manual; link available under Service
& Support in the last chapter
Adjustable parameters
Adjustable response value current / lg min. 63 A
Adjustable response value current / lg min. 63 A
Short-term delayed / tripping switchable /
I2t=ON/OFF
No
Adjustable response value current / li min. 630 A
Adjustable response value current / li max. 630 A
Ground fault protection / tripping switchable /
I2t=ON/OFF
No
circuit breaker 3VM1 IEC frame 100 breaking capacity class S
Icu=36kA @ 415V 3-pole, line protection TM210, FTFM, In=63A
overload protection Ir=63A, not adjustable short-circuit protection
Ii=10 x In nut keeper kit
Model
product brand name SENTRON
product designation Molded case circuit breaker
Product version Line protection
design of the overcurrent release TM210
protection function of the overcurrent release LI
number of poles 3
General technical data
Tension assignée d'isolement Ui 690 V
Max. rated operational voltage Ue with AC 50/60Hz 500 V
Max. rated operational voltage Ue with DC 250 V
power loss W / maximum 22 W
Active power loss / for rated value of the current / at
AC / in hot operating state / per pole
7.33 W
mechanical service life (switching cycles) / typical 10 000
Electrical endurance (switching cycles) / at AC-1 / at
380/415 V 50/60 Hz
2 000
Neutral conductors / upgradeable/retrofittable No
ground-fault monitoring version Without
product function
communication function No
other measurement function No
net weight 0.941 kg
Current
Max. rated operational current of the frame size 100 A
Courant permanent assigné Iu 63 A
operational current
at 40 degrees centigrade 63 A
at 45 degrees centigrade 63 A
at 50 degrees centigrade 63 A
at 55 degrees centigrade 62 A
at 60 degrees centigrade 61 A
at 65 degrees centigrade 60 A
at 70 degrees centigrade 58 A
Switching capacity according to IEC 60947
switching capacity class of the circuit breaker S
breaking capacity maximum short-circuit current (Icu)
at 240 V 55 kA
at 415 V 36 kA
at 440 V 20 kA
at 500 V 7 kA
breaking capacity operating short-circuit current (Ics)
at 240 V 18 kA
at 415 V 12 kA
at 440 V 8 kA
at 500 V 2.5 kA
short-circuit current making capacity (Icm)
at 240 V 121 kA
at 415 V 76 kA
at 440 V 40 kA
at 500 V 11.9 kA
design of short-circuit protection For switching capacity values in DC power systems, see the 3VA
Molded Case Circuit Breaker Manual; link available under Service
& Support in the last chapter
Adjustable parameters
Adjustable response value current / lg min. 63 A
Adjustable response value current / lg min. 63 A
Short-term delayed / tripping switchable /
I2t=ON/OFF
No
Adjustable response value current / li min. 630 A
Adjustable response value current / li max. 630 A
Ground fault protection / tripping switchable /
I2t=ON/OFF
No
Hacer preguntas
(0/1,200)
- Consulta: Cuanto tiempo tarda el envio?
Responder: El tiempo de envío depende del método de envío que elijas y del destino. Los tiempos de entrega estimados generalmente se proporcionan durante el proceso de pago.
- Consulta: ¿Cómo puedo verificar la certificación de seguridad o la información de cumplimiento de un producto?
Responder: Para productos que requieren certificación o cumplimiento de seguridad, proporcionamos información relevante en la página de detalles del producto. Puede consultar las etiquetas de certificación o descripciones para asegurarse de que el producto cumpla con los estándares y regulaciones pertinentes.
- Consulta: ¿Cómo me registro como miembro y qué privilegios tienen los miembros?
Responder: Registrarse como miembro es muy simple; solo necesita proporcionar cierta información básica. Los miembros pueden disfrutar de actividades promocionales exclusivas, puntos de recompensa, pago rápido y privilegios exclusivos de servicio al cliente.
Comentarios
- G
Gilbert Aranda
17/08/2025
Siemens Disyuntor 3VM1063-4ED32-0AA0I came across this item and want to find out if I can return it if it's the wrong one.ÚtilNo ayuda - K
Kyle Buttinger
07/07/2025
Siemens Disyuntor 3VM1063-4ED32-0AA0That's a lot of cash, but it's worth it.ÚtilNo ayuda - S
Stacey Torell
24/01/2025
Siemens Disyuntor 3VM1063-4ED32-0AA0The search results were exactly what I was looking for.ÚtilNo ayuda - G
Guillermo
05/04/2024
Siemens Disyuntor 3VM1063-4ED32-0AA0¡Gracias, tenías lo que necesitaba!ÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3VM1063-4ED32-0AA0¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3VM1063-4ED32-0AA0
$ 195 .31
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 2
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Siemens Disyuntor 3VM1112-3ED42-0AA0
US$273.44
GE Disyuntor GPS1BHAM 11-16A
US$529.00
Siemens Disyuntor 3RV1011-0CA15
US$346.66
Siemens Disyuntor 3RV1021-1EA10
US$431.25
TRIAD Transformador F24-100
US$17.80
Moeller Contactor DILR22-G
US$107.69
Tyco Fusible 1206SFH100F/24-2
US$1.15
EATON Relé EASY512-DC-RC
US$150.00
UniOhm Resistor 1210W3J0151T5E
US$3.27
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Delta Ventilador PFR1212UHE-F00
Contacta con nosotros
Eaton Contactor 6702ED664-2
Contacta con nosotros
ROHM Resistor ESR03EZPF62R0
Contacta con nosotros
BANDO Belt T5-545-15
US$17.69
Contrinex Sensor BD5-S2-Q35
US$38.46
Eaton Vickers Bomba de paletas 4525VQS60E12-297AB20
Contacta con nosotros