circuit breaker 3VA1 IEC frame 630 breaking capacity class S
Icu=36kA @ 415V 4-pole, line protection TM220, ATFM, In=630A
overload protection Ir=440A...630A short-circuit protection Ii=8 x In N
conductor unprotected nut keeper kit
Model
product brand name SENTRON
product designation Molded case circuit breaker
Product version Line protection
design of the overcurrent release TM220
protection function of the overcurrent release LI
number of poles 4
General technical data
Tension assignée d'isolement Ui 800 V
Max. rated operational voltage Ue with AC 50/60Hz 690 V
Max. rated operational voltage Ue with DC 600 V
power loss W / maximum 192.9 W
Active power loss / for rated value of the current / at
AC / in hot operating state / per pole
64.3 W
mechanical service life (switching cycles) / typical 15 000
Electrical endurance (switching cycles) / at AC-1 / at
380/415 V 50/60 Hz
4 000
Electrical endurance (switching cycles) / at AC-1 / at
690 V 50/60 Hz
2 700
Neutral conductors / upgradeable/retrofittable No
ground fault monitoring version Without
product function
communication function No
other measurement function No
Current
Max. rated operational current of the frame size 630 A
Courant permanent assigné Iu 630 A
operating current
at 40 degrees centigrade 630 A
at 45 degrees centigrade 630 A
at 50 degrees centigrade 630 A
at 55 degrees centigrade 618 A
at 60 degrees centigrade 607 A
at 65 degrees centigrade 595 A
at 70 degrees centigrade 583 A
Switching capacity according to IEC 60947
switching capacity class of the circuit breaker S
maximum short-circuit current breaking capacity (Icu)
at 240 V 55 kA
at 415 V 36 kA
at 440 V 36 kA
at 500 V 25 kA
at 690 V 7 kA
operational short-circuit current breaking capacity
(Ics)
at 240 V 55 kA
at 415 V 36 kA
at 440 V 36 kA
at 500 V 25 kA
at 690 V 5 kA
short-circuit current making capacity (Icm)
at 240 V 121 kA
at 415 V 76 kA
at 440 V 76 kA
at 500 V 53 kA
at 690 V 10.5 kA
design of short-circuit protection For switching power values in DC networks, see the 3VA molded
case circuit breaker device manual; link to be found under Service
& Support in the last chapter
Adjustable parameters
Adjustable response value current / lg min. 441 A
Adjustable response value current / lg min. 630 A
Adjustable response value current / li min. 5 040 A
Adjustable response value current / li max. 5 040 A
design of the N-conductor protection Without
Ground fault protection / tripping switchable /
I2t=ON/OFF
No
Mechanical Design
height in 9.8 in
Height 248 mm
width in 7.2 in
Width 184 mm
depth in 4.3 in
depth 110 mm
Connections
arrangement of electrical connectors / for main
current circuit
Front terminal
Auxiliary circuit
number of CO contacts / for auxiliary contacts 0
Accessories
product extension / optional / motor drive Yes
Environmental conditions
protection class IP / on the front IP40
ambient temperature
during operation / minimum -25 degrees centigrade
during operation / maximum 70 degrees centigrade
during storage / minimum -40 degrees centigrade
during storage / maximum 80 degrees centigrade
Certificates
reference code / acc. to DIN EN 81346-2 Q
circuit breaker 3VA1 IEC frame 630 breaking capacity class S
Icu=36kA @ 415V 4-pole, line protection TM220, ATFM, In=630A
overload protection Ir=440A...630A short-circuit protection Ii=8 x In N
conductor unprotected nut keeper kit
Model
product brand name SENTRON
product designation Molded case circuit breaker
Product version Line protection
design of the overcurrent release TM220
protection function of the overcurrent release LI
number of poles 4
General technical data
Tension assignée d'isolement Ui 800 V
Max. rated operational voltage Ue with AC 50/60Hz 690 V
Max. rated operational voltage Ue with DC 600 V
power loss W / maximum 192.9 W
Active power loss / for rated value of the current / at
AC / in hot operating state / per pole
64.3 W
mechanical service life (switching cycles) / typical 15 000
Electrical endurance (switching cycles) / at AC-1 / at
380/415 V 50/60 Hz
4 000
Electrical endurance (switching cycles) / at AC-1 / at
690 V 50/60 Hz
2 700
Neutral conductors / upgradeable/retrofittable No
ground fault monitoring version Without
product function
communication function No
other measurement function No
Current
Max. rated operational current of the frame size 630 A
Courant permanent assigné Iu 630 A
operating current
at 40 degrees centigrade 630 A
at 45 degrees centigrade 630 A
at 50 degrees centigrade 630 A
at 55 degrees centigrade 618 A
at 60 degrees centigrade 607 A
at 65 degrees centigrade 595 A
at 70 degrees centigrade 583 A
Switching capacity according to IEC 60947
switching capacity class of the circuit breaker S
maximum short-circuit current breaking capacity (Icu)
at 240 V 55 kA
at 415 V 36 kA
at 440 V 36 kA
at 500 V 25 kA
at 690 V 7 kA
operational short-circuit current breaking capacity
(Ics)
at 240 V 55 kA
at 415 V 36 kA
at 440 V 36 kA
at 500 V 25 kA
at 690 V 5 kA
short-circuit current making capacity (Icm)
at 240 V 121 kA
at 415 V 76 kA
at 440 V 76 kA
at 500 V 53 kA
at 690 V 10.5 kA
design of short-circuit protection For switching power values in DC networks, see the 3VA molded
case circuit breaker device manual; link to be found under Service
& Support in the last chapter
Adjustable parameters
Adjustable response value current / lg min. 441 A
Adjustable response value current / lg min. 630 A
Adjustable response value current / li min. 5 040 A
Adjustable response value current / li max. 5 040 A
design of the N-conductor protection Without
Ground fault protection / tripping switchable /
I2t=ON/OFF
No
Mechanical Design
height in 9.8 in
Height 248 mm
width in 7.2 in
Width 184 mm
depth in 4.3 in
depth 110 mm
Connections
arrangement of electrical connectors / for main
current circuit
Front terminal
Auxiliary circuit
number of CO contacts / for auxiliary contacts 0
Accessories
product extension / optional / motor drive Yes
Environmental conditions
protection class IP / on the front IP40
ambient temperature
during operation / minimum -25 degrees centigrade
during operation / maximum 70 degrees centigrade
during storage / minimum -40 degrees centigrade
during storage / maximum 80 degrees centigrade
Certificates
reference code / acc. to DIN EN 81346-2 Q
Las personas que compraron este artículo también vieron
Schneider Disyuntor GV2-ME21C
US$625.00
Schneider Disyuntor A9V53263
US$200.00
Siemens Disyuntor 3RV1011-0AA10
US$337.47
TRIAD Transformador F-354X
US$68.40
Lovato Contactor BF8000E024
US$500.25
Siba Fusible NH00 63A
US$34.63
HONGFA Relé HF32FV-5-HSTF
US$1.17
EPCOS Resistor B72660M381K072
US$1.15
Los clientes ven con frecuencia
Carel Válvula de expansión E6VB2ASV00
US$839.00
Mitsubishi Compresor RE277NRAMT
US$389.00
Togami Contactor CLK-25J3
US$79.00
SHAKO Cilindro de aire JC32B110-H-M
US$121.35
PILZ Controller Módulo PST-4-24VDC-6S4O
US$7360.00
Nidec Ventilador U30R12NS1Z5-53
US$23.85
Asco Bobina de solenoide 238714-006-D
US$339.69
Publicaciones relacionadas recientes
-
02/17/2024
Método de cableado del relé PTC de nevera
El relé PTC (coeficiente de temperatura positivo) está conectado directamente en serie con el devanado secundario (devanado de arranque) y en paralelo con el devanado principal del motor.
-
05/19/2022
17 fabricantes de compresores centrífugos, en el mundo. ¿cuántos conoce?
En la última década, en un contexto de globalización económica y feroz competencia, la industria de fabricación de compresores centrífugos también ha experimentado continuas fusiones, adquisiciones y reorganizaciones.
-
05/11/2022
Reparación de averías en servoaccionamientos Ultra3000
Hemos enumerado las fallas comunes y los métodos de reparación de los servovariadores Ultra3000; si necesita reemplazar el equipo, le brindamos Servoaccionamiento Allen Bradley Rockwell.
-
08/08/2022
Motor de inducción de jaula de ardilla frente a motor de inducción de rotor bobinado: Estructura del rotor, ventajas e inconvenientes
El motor de inducción trifásico consta de dos partes básicas: el estator y el rotor. El estator es la parte fija del motor y se utiliza para generar un campo magnético giratorio.
-
01/07/2024
¿Por qué vibra el servomotor?
¿En qué casos vibrará un servomotor? ¿Qué pasa si el servomotor vibra? ¿Cómo podemos solucionar los problemas causados por la vibración? Este artículo explicará varias razones para esto.
-
06/27/2023
Principio de funcionamiento del compresor frigorífico, esquema eléctrico, estructura
El componente principal del refrigerador es el compresor. Si un frigorífico no está equipado con un compresor de buena calidad y tecnología no puede ser un buen frigorífico.
-
11/18/2023
Transmisores Rosemount Series 1151, 2088, 2051, 3051CA, 3051S y sus diferencias
El transmisor de presión Rosemount es un tipo de transmisor de presión general. Está fabricado según la ley de inducción electromagnética y la norma JB/T9248-1999.
-
08/04/2023
Aire acondicionado Mitsubishi vs Panasonic
El verano es tan difícil de pasar que las personas sin aire acondicionado son como peces fuera del agua. Es fundamental elegir un buen aire acondicionado.
-
03/10/2024
Todo lo que debe saber sobre el embrague magnético del compresor de CA del coche
Este artículo presenta los componentes del embrague magnético del compresor y su principio de funcionamiento, así como varios parámetros importantes. Además, también le brindamos algunas experiencias sobre cómo lidiar con la quema de los embragues del compresor del aire acondicionado.
-
12/05/2023
Principios y diferencias de los transmisores de 2, 3 y 4 hilos
Los transmisores de 2, 3 y 4 hilos se refieren a transmisores cuyas salidas son señales analógicas de corriente CC.