Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 0.5 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 0.35...0.5 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S00 for motor protection, CLASS 10 with
overload relay function A-release 0.35...0.5 A N-release 6.5 A screw
terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection with overload relay function
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5?W
at AC in hot operating state per pole 1.8?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
0.35?...?0.5?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 0.5?A
operating current
at AC-3
at 400 V rated value 0.5?A
operating power
at AC-3
at 230 V rated value 60?W
at 400 V rated value 120?W
at 500 V rated value 120?W
at 690 V rated value 180?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch laterally
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 1.5?A
at 230 V 1.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 100?kA
at 500 V rated value 100?kA
at 690 V rated value 100?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 100?kA
at AC at 690 V rated value 100?kA
response value current
of instantaneous short-circuit trip unit 6.5?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.5?A
at 600 V rated value 0.5?A
contact rating of auxiliary contacts according to UL C600 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gL/gG: 6 A, quick: 10 A
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 690 V gL/gG 4 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97?mm
width 65?mm
depth 97?mm
Circuit breaker size S00 for motor protection, CLASS 10 with
overload relay function A-release 0.35...0.5 A N-release 6.5 A screw
terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection with overload relay function
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5?W
at AC in hot operating state per pole 1.8?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
0.35?...?0.5?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 0.5?A
operating current
at AC-3
at 400 V rated value 0.5?A
operating power
at AC-3
at 230 V rated value 60?W
at 400 V rated value 120?W
at 500 V rated value 120?W
at 690 V rated value 180?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch laterally
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 1.5?A
at 230 V 1.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 100?kA
at 500 V rated value 100?kA
at 690 V rated value 100?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 100?kA
at AC at 690 V rated value 100?kA
response value current
of instantaneous short-circuit trip unit 6.5?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.5?A
at 600 V rated value 0.5?A
contact rating of auxiliary contacts according to UL C600 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gL/gG: 6 A, quick: 10 A
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 690 V gL/gG 4 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97?mm
width 65?mm
depth 97?mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo filtrar productos por rango de precios?
Responder: En la página de listado de productos, puede utilizar la herramienta de filtrado de precios para establecer el rango de precios deseado. El sistema mostrará los productos que cumplan con sus criterios, ayudándole a encontrar los artículos adecuados rápidamente.
- Consulta: ¿Cómo puedo consultar la cobertura de garantía de un producto?
Responder: La cobertura de garantía de un producto generalmente se especifica en la página de detalles del producto o en la información de garantía proporcionada por el fabricante. Puede revisar esta información antes de realizar una compra para comprender la cobertura de la garantía.
- Consulta: ¿Qué debo hacer si recibo un producto dañado o defectuoso?
Responder: En el raro caso de que reciba un producto dañado o defectuoso, comuníquese con nuestro servicio de atención al cliente de inmediato. Le ayudaremos a resolver el problema organizando una devolución, reemplazo o reparación, según las circunstancias.
Comentarios
- L
Lance Hymas
07/05/2025
Siemens Disyuntor 3RV2111-0FA10Thanks, you're the best friend.ÚtilNo ayuda - T
Tom Lawson
04/05/2025
Siemens Disyuntor 3RV2111-0FA10Uplifting!ÚtilNo ayuda - D
Daniil Treshchin
23/02/2025
Siemens Disyuntor 3RV2111-0FA10Exceeded my expectations!ÚtilNo ayuda - E
Elisa
28/04/2024
Siemens Disyuntor 3RV2111-0FA10Sitio fácil para comprar.ÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2111-0FA10¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2111-0FA10
$ 360 .79
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Fuji Disyuntor BB3ASB-010
US$43.08
Siemens Disyuntor 5SY6120-7CC
US$25.39
ABB Disyuntor 10103906
US$10.16
Delixi Transformador CDZB-200VA
US$70.00
Eaton Contactor DILM32-10(RDC60)
US$138.46
Raychem Fusible RGEF1200 12A
US$0.17
CRYDOM Relé CWD24120P
US$161.54
EBG Resistor UXP-800-0.25R
US$184.63
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Copeland Compresor ARE36C3-IAA-902
Contacta con nosotros
Ebmpapst Ventilador W3G 300-CB56-01
Contacta con nosotros
Relpol Relé R30N-3021-85-1012
US$7.69
CKD Cilindro de aire SCG-FB-40B-620
Contacta con nosotros
KOMPASS Bomba de pistón V18A4RSB-D2
US$1384.62