Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 40 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 32...40 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S2 for motor protection, CLASS 10 A-release
70...80 A N-release 1040 A screw terminal increased switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 29.5?W
at AC in hot operating state per pole 9.8?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 20?000
of auxiliary contacts typical 20?000
electrical endurance (switching cycles)
typical 20?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
70?...?80?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 80?A
operating current
at AC-3
at 400 V rated value 80?A
operating power
at AC-3
at 230 V rated value 22?000?W
at 400 V rated value 37?000?W
at 500 V rated value 55?000?W
at 690 V rated value 75?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 8?kA
at 690 V rated value 4?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 1?040?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 77?A
at 600 V rated value 77?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 7.5?hp
at 230 V rated value 15?hp
for three-phase AC motor
at 200/208 V rated value 25?hp
at 220/230 V rated value 30?hp
at 460/480 V rated value 60?hp
at 575/600 V rated value 75?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 160
at 500 V 125
at 690 V 100
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Circuit breaker size S2 for motor protection, CLASS 10 A-release
70...80 A N-release 1040 A screw terminal increased switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 29.5?W
at AC in hot operating state per pole 9.8?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 20?000
of auxiliary contacts typical 20?000
electrical endurance (switching cycles)
typical 20?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
70?...?80?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 80?A
operating current
at AC-3
at 400 V rated value 80?A
operating power
at AC-3
at 230 V rated value 22?000?W
at 400 V rated value 37?000?W
at 500 V rated value 55?000?W
at 690 V rated value 75?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 8?kA
at 690 V rated value 4?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 1?040?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 77?A
at 600 V rated value 77?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 7.5?hp
at 230 V rated value 15?hp
for three-phase AC motor
at 200/208 V rated value 25?hp
at 220/230 V rated value 30?hp
at 460/480 V rated value 60?hp
at 575/600 V rated value 75?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 160
at 500 V 125
at 690 V 100
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo buscar productos en el sitio web?
Responder: Puede utilizar la barra de búsqueda ubicada en la parte superior del sitio web para ingresar palabras clave y encontrar los productos deseados. Alternativamente, puede navegar a través de diferentes categorías y filtrar opciones para limitar su búsqueda.
- Consulta: ¿Admiten envíos internacionales?
Responder: Sí, admitimos envíos internacionales. Puede seleccionar la opción de envío internacional y proporcionar la dirección de envío correspondiente durante el proceso de pago. Tenga en cuenta que el envío internacional puede requerir tarifas y tiempo adicionales.
- Consulta: ¿Cómo puedo verificar el estado de mi artículo pendiente?
Responder: Para verificar el estado de su artículo pendiente, comuníquese con nuestro equipo de servicio al cliente. Le proporcionarán la información más reciente sobre la disponibilidad y la fecha estimada de envío del artículo.
Comentarios
- J
Jon Nash
14/09/2025
Siemens Disyuntor 3RV2032-4RA15Wonderful experience, I’ll shop here again.ÚtilNo ayuda - K
Kandy Siroonian
12/02/2025
Siemens Disyuntor 3RV2032-4RA15Thanks, I really appreciate it!ÚtilNo ayuda - R
Richard Everett
23/11/2024
Siemens Disyuntor 3RV2032-4RA15Expressway DeliveryÚtilNo ayuda - C
Celia
24/04/2024
Siemens Disyuntor 3RV2032-4RA15Great serviceÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2032-4RA15¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2032-4RA15
$ 875 .82
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Siemens Disyuntor 3RV2021-1AA10
US$228.14
Eaton Moeller Disyuntor LZMS1-A63
US$338.24
ABB Disyuntor GSH201 AC-C63/0.03
US$45.31
TRIAD Transformador VPT36-2780
US$137.88
TE Contactor EVC500 2272991-1
US$1093.00
Ferraz Shawmut Fusible A120UD73LI500
US$176.92
TYCO Relé V23047-A1110-A511
US$11.54
UniOhm Resistor 0.25W680R
US$3.85
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Teco TAIAN VFD Frequency Converter F510-4125-C
Contacta con nosotros
LG LS Contactor MC-9a 1316001000
Contacta con nosotros
Mitsubishi Compresor HNB71FA-YJHC
US$2353.84
BANDO Belt XL-146-381G
US$164.04
Omega Caudalímetro FL-10P
US$942.31
Danfoss Válvula de expansión TGE 067N2165
Contacta con nosotros
Copeland Compresor 3DG3A090E-TFE-801
Contacta con nosotros
Emerson Alco Válvula de expansión TCL 1/2RWS-01
Contacta con nosotros