Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 52 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 42...52 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S2 for motor protection, CLASS 10 A-release
42...52 A N-release 741 A screw terminal Standard switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 24.5?W
at AC in hot operating state per pole 8.2?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
42?...?52?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 52?A
operating current
at AC-3
at 400 V rated value 52?A
operating power
at AC-3
at 230 V rated value 15?000?W
at 400 V rated value 22?000?W
at 500 V rated value 30?000?W
at 690 V rated value 45?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 30?kA
at 500 V rated value 4?kA
at 690 V rated value 2?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 65?kA
at AC at 500 V rated value 8?kA
at AC at 690 V rated value 4?kA
response value current
of instantaneous short-circuit trip unit 741?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 52?A
at 600 V rated value 52?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 5?hp
at 230 V rated value 10?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 20?hp
at 460/480 V rated value 40?hp
at 575/600 V rated value 50?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 160
at 500 V 125
at 690 V 100
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Circuit breaker size S2 for motor protection, CLASS 10 A-release
42...52 A N-release 741 A screw terminal Standard switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 24.5?W
at AC in hot operating state per pole 8.2?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
42?...?52?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 52?A
operating current
at AC-3
at 400 V rated value 52?A
operating power
at AC-3
at 230 V rated value 15?000?W
at 400 V rated value 22?000?W
at 500 V rated value 30?000?W
at 690 V rated value 45?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 30?kA
at 500 V rated value 4?kA
at 690 V rated value 2?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 65?kA
at AC at 500 V rated value 8?kA
at AC at 690 V rated value 4?kA
response value current
of instantaneous short-circuit trip unit 741?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 52?A
at 600 V rated value 52?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 5?hp
at 230 V rated value 10?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 20?hp
at 460/480 V rated value 40?hp
at 575/600 V rated value 50?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 160
at 500 V 125
at 690 V 100
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Hacer preguntas
(0/1,200)
- Consulta: Cuanto tiempo tarda el envio?
Responder: El tiempo de envío depende del método de envío que elijas y del destino. Los tiempos de entrega estimados generalmente se proporcionan durante el proceso de pago.
- Consulta: ¿Cómo puedo verificar la certificación de seguridad o la información de cumplimiento de un producto?
Responder: Para productos que requieren certificación o cumplimiento de seguridad, proporcionamos información relevante en la página de detalles del producto. Puede consultar las etiquetas de certificación o descripciones para asegurarse de que el producto cumpla con los estándares y regulaciones pertinentes.
- Consulta: ¿Cómo me registro como miembro y qué privilegios tienen los miembros?
Responder: Registrarse como miembro es muy simple; solo necesita proporcionar cierta información básica. Los miembros pueden disfrutar de actividades promocionales exclusivas, puntos de recompensa, pago rápido y privilegios exclusivos de servicio al cliente.
Comentarios
- D
Douglas Gilbert
13/09/2025
Siemens Disyuntor 3RV2031-4WA15Speedy and stresslessÚtilNo ayuda - W
Wayne Wilson
09/09/2025
Siemens Disyuntor 3RV2031-4WA15A+ serviceÚtilNo ayuda - J
Jose Rodriguez
08/06/2025
Siemens Disyuntor 3RV2031-4WA15Easy peasy, found exactly what I needed and ordered.ÚtilNo ayuda - B
Bruno
11/02/2024
Siemens Disyuntor 3RV2031-4WA15Was easy enough. Items were in great condition.ÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2031-4WA15¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2031-4WA15
$ 619 .16
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Terasaki Disyuntor S100-NF
US$519.23
Mitsubishi Disyuntor NF32-SV 3P 3A
US$58.59
Fuji Disyuntor EG203C-3P175A
US$141.15
Fuji Disyuntor BW250JAG-3P225
US$181.54
LUNDAHL Transformador LL1671
US$538.46
Ferraz Shawmut Fusible BS236UH25V600
US$38.46
TAKAMISAWA Relé 24V<br>
US$4.62
UniOhm Resistor 0603WAF110JT5E
US$4.81
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Bristol Compresor H89A423CBCH
Contacta con nosotros
SMC Válvula proporcional ITV3030-402S2
Contacta con nosotros
Copeland Compresor ZR34KH-TFD-522
US$868.50
UniOhm Resistor 2W4.7R
Contacta con nosotros
SAND Transmisor PT1625-PF3/8"-85Bar-250/460
Contacta con nosotros
ABB Servo Motor PS130/6-200-P-LSS-4101
Contacta con nosotros
Ebmpapst Ventilador A1G250-AI37-52
Contacta con nosotros
KITA Interruptor KP102-F2
US$59.62