Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 28 |
| Número de polos | 4 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 23...28 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S0 for motor protection, CLASS 10 A-release
23...28 A N-release 364 A ring cable lug connection Standard
switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S0
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 13.25?W
at AC in hot operating state per pole 4.4?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP00
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
23?...?28?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 28?A
operating current
at AC-3
at 400 V rated value 28?A
operating power
at AC-3
at 230 V rated value 7?500?W
at 400 V rated value 15?000?W
at 500 V rated value 18?500?W
at 690 V rated value 22?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 25?kA
at 500 V rated value 5?kA
at 690 V rated value 2?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 55?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 4?kA
response value current
of instantaneous short-circuit trip unit 364?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 28?A
at 600 V rated value 28?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 2?hp
at 230 V rated value 5?hp
for three-phase AC motor
at 200/208 V rated value 7.5?hp
at 220/230 V rated value 10?hp
at 460/480 V rated value 20?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 400 V gL/gG 63 A
at 500 V gL/gG 63 A
at 690 V gL/gG 63 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97?mm
width 45?mm
depth 97?mm
Circuit breaker size S0 for motor protection, CLASS 10 A-release
23...28 A N-release 364 A ring cable lug connection Standard
switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S0
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 13.25?W
at AC in hot operating state per pole 4.4?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP00
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
23?...?28?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 28?A
operating current
at AC-3
at 400 V rated value 28?A
operating power
at AC-3
at 230 V rated value 7?500?W
at 400 V rated value 15?000?W
at 500 V rated value 18?500?W
at 690 V rated value 22?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 25?kA
at 500 V rated value 5?kA
at 690 V rated value 2?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 55?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 4?kA
response value current
of instantaneous short-circuit trip unit 364?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 28?A
at 600 V rated value 28?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 2?hp
at 230 V rated value 5?hp
for three-phase AC motor
at 200/208 V rated value 7.5?hp
at 220/230 V rated value 10?hp
at 460/480 V rated value 20?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 400 V gL/gG 63 A
at 500 V gL/gG 63 A
at 690 V gL/gG 63 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97?mm
width 45?mm
depth 97?mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo cambiar mi dirección de correo electrónico asociada a mi cuenta?
Responder: Para cambiar la dirección de correo electrónico asociada a su cuenta, comuníquese con nuestro equipo de servicio al cliente y proporcióneles la información de verificación necesaria. Ellos le ayudarán a actualizar su dirección de correo electrónico.
- Consulta: ¿Puedo guardar artículos en mi carrito para comprarlos más tarde?
Responder: Sí, puede guardar artículos en su carrito para futuras compras. Al agregar artículos a su lista de deseos o guardarlos en su cuenta, podrá acceder fácilmente a ellos y comprarlos más tarde sin necesidad de buscarlos nuevamente.
- Consulta: ¿Cómo puedo ver la calificación promedio y las reseñas de los usuarios de un producto?
Responder: En la página de detalles del producto, puede ver la calificación promedio y las reseñas de los usuarios. Alentamos a los usuarios a compartir sus experiencias de compra y comentarios sobre los productos, para que pueda comprender mejor las opiniones y sugerencias de otros compradores.
Comentarios
- C
Carla Garner
18/07/2025
Siemens Disyuntor 3RV2021-4NA40Needed precisely in all waysÚtilNo ayuda - T
Tom Gross
02/03/2025
Siemens Disyuntor 3RV2021-4NA40I'm feeling very happy and satisfied.ÚtilNo ayuda - R
Rick Glossett
07/11/2024
Siemens Disyuntor 3RV2021-4NA40Excellent and incredibleÚtilNo ayuda - E
Esperanza
26/05/2024
Siemens Disyuntor 3RV2021-4NA40Fast, and the price was a good oneÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2021-4NA40¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2021-4NA40
$ 428 .33
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Mitsubishi Disyuntor NF250-SW 4P 250A
US$336.72
Siemens Disyuntor 5SY6104-7
US$23.44
Siemens Disyuntor 3RV1011-0DA10
US$271.99
Siemens Disyuntor 5SL6232-7CC
US$38.67
Aiharadenki Transformador SR-500
US$192.30
Eaton Contactor DILM12-01(380V50HZ
US$44.62
Littelfuse Fusible 0215008.MXGP
US$0.58
PARKER Relé PSB040AF1A5
US$576.92
Caddock Resistor MP915-7.50-1%
US$7.38
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
VACON VFD Frequency Converter NXS07305A2L0SSAA1A2
Contacta con nosotros
Yageo Resistor FRM-50JT-52-2R2
US$76.92
YTP Guía lineal LMF12UU
US$5.00
AirTAC Cilindro de aire MDD25X30
US$37.69
Jeou Gang Válvula de desbordamiento BSG-06-2PN-1-32
Contacta con nosotros
THK Cojinete NHS 3TL
US$323.08
Burkert Transmisor 00559612
US$2656.25
Yaskawa Servo Motor SGMBH-2BDCA61
US$461.54
Kompass Bomba de paletas T6DR-024-2R00-050-A4
Contacta con nosotros
Mitsubishi Compresor RB233YABC
US$579.00