| Tipo | 3RV1 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 2.5 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 1.8...2.5 A |
| Adecuado para motores de inducción con P | 0.75 kW |
| Liberaciones instantáneas de sobrecorriente | 33 A |
| Short-circuit breaking capacidad | 100 kA |
| Peso approx. | 0.298 kg |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S00 for motor protection, CLASS 10 A-release1.8...2.5 A
N-release 33 A Screw terminal Standard switchingcapacity with transverse auxiliary switch 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 1.8 - 2.5
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value2.5A
operating current
at AC-3 at 400 V rated value 2.5 A
operating power at AC-3
at 230 V rated value 370 W
at 400 V rated value750 W
at 500 V rated value110 W
at 690 V rated value1500 W
operating frequency at AC-3 maximum 15 1/h
design of the auxiliary switcht ransverse
number of NC contacts for auxiliary contact 1 note 1
number of NO contacts for auxiliary contacts 1 note 1
number of CO contacts for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 2 A at 110 V 2 A at 120 V 2 A at 125 V 2 A at 230 V 0.5 A
operating current of auxiliary contacts at DC-13
at 24 V 1 A at 60 V 0.15 A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 2 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 2 kA
response value current
of instantaneous short-circuit trip unit 33 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value2.5A
at 600 V rated value2.5 A
yielded mechanical performance hp
for single-phase AC motor
at 230 V rated value 0.166 hp
for three-phase AC motor
at 200/208 V rated value 0.5 hp
at 220/230 V rated value 0.5 hp
at 460/480 V rated value 1 hp
at 575/600 V rated value1.5 hp
contact rating of auxiliary contacts according to UL C300 R300
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switchrequired
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit currentIk less 400 A)
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 35 A
at 500 V gL/gG 25 A
at 690 V gL/gG 25 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Circuit breaker size S00 for motor protection, CLASS 10 A-release1.8...2.5 A
N-release 33 A Screw terminal Standard switchingcapacity with transverse auxiliary switch 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 1.8 - 2.5
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value2.5A
operating current
at AC-3 at 400 V rated value 2.5 A
operating power at AC-3
at 230 V rated value 370 W
at 400 V rated value750 W
at 500 V rated value110 W
at 690 V rated value1500 W
operating frequency at AC-3 maximum 15 1/h
design of the auxiliary switcht ransverse
number of NC contacts for auxiliary contact 1 note 1
number of NO contacts for auxiliary contacts 1 note 1
number of CO contacts for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 2 A at 110 V 2 A at 120 V 2 A at 125 V 2 A at 230 V 0.5 A
operating current of auxiliary contacts at DC-13
at 24 V 1 A at 60 V 0.15 A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 2 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 2 kA
response value current
of instantaneous short-circuit trip unit 33 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value2.5A
at 600 V rated value2.5 A
yielded mechanical performance hp
for single-phase AC motor
at 230 V rated value 0.166 hp
for three-phase AC motor
at 200/208 V rated value 0.5 hp
at 220/230 V rated value 0.5 hp
at 460/480 V rated value 1 hp
at 575/600 V rated value1.5 hp
contact rating of auxiliary contacts according to UL C300 R300
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switchrequired
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit currentIk less 400 A)
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 35 A
at 500 V gL/gG 25 A
at 690 V gL/gG 25 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo cambiar mi dirección de correo electrónico asociada a mi cuenta?
Responder: Para cambiar la dirección de correo electrónico asociada a su cuenta, comuníquese con nuestro equipo de servicio al cliente y proporcióneles la información de verificación necesaria. Ellos le ayudarán a actualizar su dirección de correo electrónico.
- Consulta: ¿Puedo guardar artículos en mi carrito para comprarlos más tarde?
Responder: Sí, puede guardar artículos en su carrito para futuras compras. Al agregar artículos a su lista de deseos o guardarlos en su cuenta, podrá acceder fácilmente a ellos y comprarlos más tarde sin necesidad de buscarlos nuevamente.
- Consulta: ¿Cómo puedo ver la calificación promedio y las reseñas de los usuarios de un producto?
Responder: En la página de detalles del producto, puede ver la calificación promedio y las reseñas de los usuarios. Alentamos a los usuarios a compartir sus experiencias de compra y comentarios sobre los productos, para que pueda comprender mejor las opiniones y sugerencias de otros compradores.
Comentarios
- F
Fernando
22/09/2024
Siemens Disyuntor 3RV1011-1CA15El 3RV1011-1CA15 de Siemens me ha impresionado por su capacidad de corte de 50 kA. Esto lo convierte en una excelente opción para proteger circuitos con alto riesgo de cortocircuito. Además, su tamaño compacto y su fácil montaje lo hacen ideal para espacios reducidos. Lo recomiendo para aplicaciones industriales y comerciales donde se necesita una protección robusta.ÚtilNo ayuda - J
Jimena
22/07/2024
Siemens Disyuntor 3RV1011-1CA15El Siemens 3RV1011-1CA15 es un interruptor automático confiable y eficiente. Su protección contra sobrecargas y cortocircuitos es excelente, y su curva de disparo C lo hace adecuado para una amplia gama de aplicaciones. Lo recomiendo para cualquier instalación eléctrica donde se necesite una protección segura y confiable.ÚtilNo ayuda - I
Inés
07/07/2024
Siemens Disyuntor 3RV1011-1CA15El Siemens 3RV1011-1CA15 es un interruptor automático de alta calidad que ofrece una excelente protección contra sobrecargas y cortocircuitos. Su curva de disparo C lo hace ideal para aplicaciones generales, y su montaje sobre riel DIN facilita su instalación. Lo recomiendo para cualquier aplicación donde se necesite una protección confiable y eficiente.ÚtilNo ayuda - M
Marcos
03/04/2024
Siemens Disyuntor 3RV1011-1CA15excelenteÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV1011-1CA15¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV1011-1CA15
$ 401 .21
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Fuji Disyuntor BW250EAG-3P150
US$1573.08
Siemens Disyuntor 3RV2021-4FA10
US$555.59
Mitsubishi Disyuntor NF400-SP
US$679.69
Siemens Disyuntor 5SY6103-8CC
US$35.16
Delixi Transformador JBK5-200VA
US$60.00
TE Contactor EV200ADANA
US$405.09
Ferraz Shawmut Fusible BS36UL69V90
US$38.46
TYCO Relé SR4D4024
US$69.62
UniOhm Resistor 0603WAF3604T5E
US$6.73
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
NSK Servoaccionamiento ESA-Y2005C23-2
Contacta con nosotros
MINDMAN Cilindro de aire MCQA-27-40-55M
US$192.31
FAG Cojinete B7016-C-T-P4S-UL
US$900.00
NORGREN Válvula de retención T1000C2800
Contacta con nosotros
Copeland Compresor RSL2-0101-CAV-702
Contacta con nosotros
LG LS Contactor MC-12a 1317100500
Contacta con nosotros
Copeland Compresor ZR160KCE-TED-561
Contacta con nosotros
Mitsubishi Compresor RB233YABC
US$579.00