Tipo | 3RV1 |
Tipo de disyuntor | Motor Protection Circuit Breakers |
Corriente nominal | 0.16 |
Número de polos | 1 pole |
Rango de ajuste para disparadores de sobrecarga térmica | 0.11...0.16 A |
Adecuado para motores de inducción con P | 0.04 kW |
Liberaciones instantáneas de sobrecorriente | 2.1 A |
Short-circuit breaking capacidad | 100 kA |
Peso approx. | 0.245 kg |
¡El Siemens Circuit Breaker es de alta calidad!
product brand name SIRIUS
product designationCircuit breaker
design of the productFor motor protection
product type designation3RV1
General technical data
size of the circuit-breakerS00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state5.5 W
at AC in hot operating state per pole1.8 W
insulation voltage with degree of pollution 3 at AC rated value690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation in networks
with grounded star point betweenmain and auxiliary circuit 400V
protection class IP on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea levelmaximum 2 000 mambient temperature
during operation-20 - +60 degrees centigrade
during storage-50 - +80 degrees centigrade
during transport-50 - +80 degrees centigrade
temperature compensation-20 - +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release0.11 - 0.16 A
operating voltage rated value690 V at AC-3 rated value maximum 690 V
operating frequency rated value50 - 60 Hz
operating current rated value 0.16 A
operating current
at AC-3
at 400 V rated value 0.16 A
operating power
at AC-3v at 230 V rated value25 W
at 400 V rated value40 W
at 500 V rated value60 W
at 690 V rated value60 Woperating frequency
at AC-3 maximum15 1/h
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1 note 1
number of NO contacts for auxiliary contacts 1 note 1
number of CO contacts for auxiliary contacts 0
operating current of auxiliary contacts at AC-15 at 24 V 2A at 110 V 2A at 120 V 2A at 125 V 2A at 230 V 0.5A
operating current of auxiliary contacts at DC-13 at 24 V 1A at 60 V 0.15A
Protective and monitoring functions
product function ground fault detection No phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current of instantaneous short-circuit trip unit 2.1 A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.16 A
at 600 V rated value 0.16 A
contact rating of auxiliary contacts according to ULC300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit tripmagnetic
design of the fuse link
for short-circuit protection of the auxiliary switch required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit currentIk < 400 A)
design of the fuse link for IT network for short-circuitprotection of the main circuit
at 240 V none required
at 400 V None required
at 500 V None required
at 690 V None required
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
product brand name SIRIUS
product designationCircuit breaker
design of the productFor motor protection
product type designation3RV1
General technical data
size of the circuit-breakerS00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state5.5 W
at AC in hot operating state per pole1.8 W
insulation voltage with degree of pollution 3 at AC rated value690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation in networks
with grounded star point betweenmain and auxiliary circuit 400V
protection class IP on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea levelmaximum 2 000 mambient temperature
during operation-20 - +60 degrees centigrade
during storage-50 - +80 degrees centigrade
during transport-50 - +80 degrees centigrade
temperature compensation-20 - +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release0.11 - 0.16 A
operating voltage rated value690 V at AC-3 rated value maximum 690 V
operating frequency rated value50 - 60 Hz
operating current rated value 0.16 A
operating current
at AC-3
at 400 V rated value 0.16 A
operating power
at AC-3v at 230 V rated value25 W
at 400 V rated value40 W
at 500 V rated value60 W
at 690 V rated value60 Woperating frequency
at AC-3 maximum15 1/h
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1 note 1
number of NO contacts for auxiliary contacts 1 note 1
number of CO contacts for auxiliary contacts 0
operating current of auxiliary contacts at AC-15 at 24 V 2A at 110 V 2A at 120 V 2A at 125 V 2A at 230 V 0.5A
operating current of auxiliary contacts at DC-13 at 24 V 1A at 60 V 0.15A
Protective and monitoring functions
product function ground fault detection No phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current of instantaneous short-circuit trip unit 2.1 A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.16 A
at 600 V rated value 0.16 A
contact rating of auxiliary contacts according to ULC300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit tripmagnetic
design of the fuse link
for short-circuit protection of the auxiliary switch required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit currentIk < 400 A)
design of the fuse link for IT network for short-circuitprotection of the main circuit
at 240 V none required
at 400 V None required
at 500 V None required
at 690 V None required
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Las personas que compraron este artículo también vieron
Siemens Disyuntor 5SL6304-7CC
US$70.31
Terasaki Disyuntor XS225NS
US$690.00
Siemens Disyuntor 3RV1041-4KA15
US$1030.73
TRIAD Transformador F16-070
US$26.73
Eaton Contactor DILM25-01C(24V50HZ)
US$192.31
Littelfuse Fusible 0215008.MXP
US$4.03
TOKY Relé HP7-RB40W/096
US$196.00
UniOhm Resistor 1210W2J0361T5E
US$46.15
Los clientes ven con frecuencia
Carel Válvula de expansión E6VB2ASV00
US$839.00
Mitsubishi Compresor RE277NRAMT
US$389.00
Togami Contactor CLK-25J3
US$79.00
Burgmann Sello mecánico HJ92N-45
US$238.46
P+F Pepperl Fuchs Sensor OBT15-R3-E0
US$152.49
CML Relé CPS-01-420-1
US$186.54
Publicaciones relacionadas recientes
-
05/19/2022
17 fabricantes de compresores centrífugos, en el mundo. ¿cuántos conoce?
En la última década, en un contexto de globalización económica y feroz competencia, la industria de fabricación de compresores centrífugos también ha experimentado continuas fusiones, adquisiciones y reorganizaciones.
-
05/12/2022
Reparación de averías en servoaccionamientos Ultra3000
Hemos enumerado las fallas comunes y los métodos de reparación de los servovariadores Ultra3000; si necesita reemplazar el equipo, le brindamos Servoaccionamiento Allen Bradley Rockwell.
-
08/08/2023
Método de cálculo del peso por metro de tubo de cobre para aire acondicionado
Método de cálculo del peso por metro de tubería de cobre para aire acondicionado.
-
02/17/2024
Método de cableado del relé PTC de nevera
El relé PTC (coeficiente de temperatura positivo) está conectado directamente en serie con el devanado secundario (devanado de arranque) y en paralelo con el devanado principal del motor.
-
01/08/2024
¿Por qué vibra el servomotor?
¿En qué casos vibrará un servomotor? ¿Qué pasa si el servomotor vibra? ¿Cómo podemos solucionar los problemas causados por la vibración? Este artículo explicará varias razones para esto.
-
08/04/2023
Aire acondicionado Mitsubishi vs Panasonic
El verano es tan difícil de pasar que las personas sin aire acondicionado son como peces fuera del agua. Es fundamental elegir un buen aire acondicionado.
-
03/10/2024
Todo lo que debe saber sobre el embrague magnético del compresor de CA del coche
Este artículo presenta los componentes del embrague magnético del compresor y su principio de funcionamiento, así como varios parámetros importantes. Además, también le brindamos algunas experiencias sobre cómo lidiar con la quema de los embragues del compresor del aire acondicionado.
-
06/27/2023
Principio de funcionamiento del compresor frigorífico, esquema eléctrico, estructura
El componente principal del refrigerador es el compresor. Si un frigorífico no está equipado con un compresor de buena calidad y tecnología no puede ser un buen frigorífico.
-
07/29/2023
Compresor Scroll Vs. Compresor rotativo para CA
El compresor scrollue inventado en 1905 por el francés Copeland. Creó la compañía Copeland en los Estados Unidos, donde se utilizan principalmente acondicionadores de aire de agua
-
12/05/2023
Principios y diferencias de los transmisores de 2, 3 y 4 hilos
Los transmisores de 2, 3 y 4 hilos se refieren a transmisores cuyas salidas son señales analógicas de corriente CC.