Mejores selecciones
Siemens Circuit Breake 3WL1106-3CB36-4GA2
$ 6,544 .92
(5) 1
Comentarios
Cantidad
MOQ : 1
Pagos
¡El Siemens Circuit Breaker es de alta calidad!
withdrawable circuit breaker with guide frame 3-pole, size I, IEC
In=630A to 690V, AC50/60Hz Icu=66kA at 500V rear connection
horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-
1 in Motorized/manual operating mechanism with spring charging
motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60
Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1
50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd
auxiliary release 2NO+2NC
Model
product brand name SENTRON
product designation ACB
design of the product IEC 60947-2
design of the actuating element Pushbutton
type of the driving mechanism Manual/motorized operating mechanism with mechanical and
electrical closing
type of the driving mechanism / motor drive Yes
design of the overcurrent release ETU25B
General technical data
number of poles 3
size of the circuit-breaker 1
utilization category B
circuit-breaker / Design 3WL1
Voltage
Rated insulation voltage Ui 1 000 V
insulation voltage / rated value 1 000 V
operating voltage
at AC / at 50/60 Hz / rated value 690 V
Protection class
protection class IP IP20
protection class IP / on the front IP20
protection function of the overcurrent release LSI
Dissipation
power loss W
for rated value of the current / at AC / in hot
operating state / per pole
65 W
maximum 195 W
Current
continuous current / rated value / maximum 630 A
continuous current / rated value 630 A
adjustable current response value current
of the current-dependent overload release / fullscale value
630 A
of instantaneous short-circuit trip unit / initial
value
12 600 A
of instantaneous short-circuit trip unit / full-scale
value
12 600 A
Main circuit
operating frequency
1 / rated value 50 Hz
2 / rated value 60 Hz
operational current
at 40 degrees centigrade / rated value 630 A
at 50 degrees centigrade / rated value 630 A
at 55 degrees centigrade / rated value 630 A
at 60 degrees centigrade / rated value 630 A
at 65 degrees centigrade / rated value 630 A
at 70 degrees centigrade / rated value 630 A
Auxiliary circuit
number of NC contacts / for auxiliary contacts 2
number of NO contacts / for auxiliary contacts 2
Suitability
suitability for use Plant / motor protection
Adjustable parameters
adjustable current response value current / of the
current-dependent overload release / initial value
252 A
Product details
product component
trip indicator Yes
voltage trigger Yes
undervoltage release No
design of the auxiliary switch 2 NO + 2 NC
product extension / optional / motor drive No
Product function
product function
grounding protection No
phase failure detection Yes
Display and operation
display version without display
Short circuit
breaking capacity operating short-circuit current
(Ics) / at 415 V / rated value
66 kA
breaking capacity operating short-circuit current
(Ics) / at 500 V / rated value
66 kA
breaking capacity operating short-circuit current
(Ics) / at 690 V / rated value
50 kA
breaking capacity maximum short-circuit
current (Icu) / at 415 V / rated value
66 kA
breaking capacity maximum short-circuit
current (Icu) / at 500 V / rated value
66 kA
breaking capacity maximum short-circuit
current (Icu) / at 690 V / rated value
50 kA
Connections
arrangement of electrical connectors / for main
current circuit
Main connection rear side horizontal
type of electrical connection / for main current circuit busbar connection
Mechanical Design
height 460 mm
width 320 mm
depth 456 mm
fastening method drawer unit
Environmental conditions
ambient temperature / during operation
minimum -20 degrees centigrade
maximum 70 degrees centigrade
ambient temperature / during storage
minimum -40 degrees centigrade
maximum 70 degrees centigrade
Certificates
reference code
acc. to DIN EN 61346-2 Q
acc. to IEC 81346-2 Q
withdrawable circuit breaker with guide frame 3-pole, size I, IEC
In=630A to 690V, AC50/60Hz Icu=66kA at 500V rear connection
horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-
1 in Motorized/manual operating mechanism with spring charging
motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60
Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1
50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd
auxiliary release 2NO+2NC
Model
product brand name SENTRON
product designation ACB
design of the product IEC 60947-2
design of the actuating element Pushbutton
type of the driving mechanism Manual/motorized operating mechanism with mechanical and
electrical closing
type of the driving mechanism / motor drive Yes
design of the overcurrent release ETU25B
General technical data
number of poles 3
size of the circuit-breaker 1
utilization category B
circuit-breaker / Design 3WL1
Voltage
Rated insulation voltage Ui 1 000 V
insulation voltage / rated value 1 000 V
operating voltage
at AC / at 50/60 Hz / rated value 690 V
Protection class
protection class IP IP20
protection class IP / on the front IP20
protection function of the overcurrent release LSI
Dissipation
power loss W
for rated value of the current / at AC / in hot
operating state / per pole
65 W
maximum 195 W
Current
continuous current / rated value / maximum 630 A
continuous current / rated value 630 A
adjustable current response value current
of the current-dependent overload release / fullscale value
630 A
of instantaneous short-circuit trip unit / initial
value
12 600 A
of instantaneous short-circuit trip unit / full-scale
value
12 600 A
Main circuit
operating frequency
1 / rated value 50 Hz
2 / rated value 60 Hz
operational current
at 40 degrees centigrade / rated value 630 A
at 50 degrees centigrade / rated value 630 A
at 55 degrees centigrade / rated value 630 A
at 60 degrees centigrade / rated value 630 A
at 65 degrees centigrade / rated value 630 A
at 70 degrees centigrade / rated value 630 A
Auxiliary circuit
number of NC contacts / for auxiliary contacts 2
number of NO contacts / for auxiliary contacts 2
Suitability
suitability for use Plant / motor protection
Adjustable parameters
adjustable current response value current / of the
current-dependent overload release / initial value
252 A
Product details
product component
trip indicator Yes
voltage trigger Yes
undervoltage release No
design of the auxiliary switch 2 NO + 2 NC
product extension / optional / motor drive No
Product function
product function
grounding protection No
phase failure detection Yes
Display and operation
display version without display
Short circuit
breaking capacity operating short-circuit current
(Ics) / at 415 V / rated value
66 kA
breaking capacity operating short-circuit current
(Ics) / at 500 V / rated value
66 kA
breaking capacity operating short-circuit current
(Ics) / at 690 V / rated value
50 kA
breaking capacity maximum short-circuit
current (Icu) / at 415 V / rated value
66 kA
breaking capacity maximum short-circuit
current (Icu) / at 500 V / rated value
66 kA
breaking capacity maximum short-circuit
current (Icu) / at 690 V / rated value
50 kA
Connections
arrangement of electrical connectors / for main
current circuit
Main connection rear side horizontal
type of electrical connection / for main current circuit busbar connection
Mechanical Design
height 460 mm
width 320 mm
depth 456 mm
fastening method drawer unit
Environmental conditions
ambient temperature / during operation
minimum -20 degrees centigrade
maximum 70 degrees centigrade
ambient temperature / during storage
minimum -40 degrees centigrade
maximum 70 degrees centigrade
Certificates
reference code
acc. to DIN EN 61346-2 Q
acc. to IEC 81346-2 Q
Las personas que compraron este artículo también vieron
Siemens Disyuntor 3VL2716-3AA33-0AA0
US$644.53
Siemens Disyuntor 3VT8110-1AA04-0AA0
US$390.23
Schneider Disyuntor LS8F18432G
US$625.00
Schneider Disyuntor EA9AN2C20
US$250.00
Tamura Transformador 3FD-216
US$27.50
Hartland Controls Contactor HCC-3XQ02CG
US$156.25
PHOENIX Relé 2909522
US$82.31
Arcol Resistor HS25270RJ
US$19.23
Los clientes ven con frecuencia
Carel Válvula de expansión E6VB2ASV00
US$839.00
Mitsubishi Compresor RE277NRAMT
US$389.00
Togami Contactor CLK-25J3
US$79.00
Honeywell Sensor P8000A0007G
US$1950.00
Copeland Compresor VR84KS-TFP-522
US$1115.38
AirTAC Cilindro de aire SE40X800
US$157.50
Ingersoll Rand Filtro 88343181
US$53.85
Publicaciones relacionadas recientes
-
05/12/2022
Reparación de averías en servoaccionamientos Ultra3000
Hemos enumerado las fallas comunes y los métodos de reparación de los servovariadores Ultra3000; si necesita reemplazar el equipo, le brindamos Servoaccionamiento Allen Bradley Rockwell.
-
12/05/2023
Principios y diferencias de los transmisores de 2, 3 y 4 hilos
Los transmisores de 2, 3 y 4 hilos se refieren a transmisores cuyas salidas son señales analógicas de corriente CC.
-
11/18/2023
Transmisores Rosemount Series 1151, 2088, 2051, 3051CA, 3051S y sus diferencias
El transmisor de presión Rosemount es un tipo de transmisor de presión general. Está fabricado según la ley de inducción electromagnética y la norma JB/T9248-1999.
-
08/04/2023
Aire acondicionado Mitsubishi vs Panasonic
El verano es tan difícil de pasar que las personas sin aire acondicionado son como peces fuera del agua. Es fundamental elegir un buen aire acondicionado.
-
05/19/2022
17 fabricantes de compresores centrífugos, en el mundo. ¿cuántos conoce?
En la última década, en un contexto de globalización económica y feroz competencia, la industria de fabricación de compresores centrífugos también ha experimentado continuas fusiones, adquisiciones y reorganizaciones.
-
03/10/2024
Todo lo que debe saber sobre el embrague magnético del compresor de CA del coche
Este artículo presenta los componentes del embrague magnético del compresor y su principio de funcionamiento, así como varios parámetros importantes. Además, también le brindamos algunas experiencias sobre cómo lidiar con la quema de los embragues del compresor del aire acondicionado.
-
02/17/2024
Método de cableado del relé PTC de nevera
El relé PTC (coeficiente de temperatura positivo) está conectado directamente en serie con el devanado secundario (devanado de arranque) y en paralelo con el devanado principal del motor.
-
06/27/2023
Principio de funcionamiento del compresor frigorífico, esquema eléctrico, estructura
El componente principal del refrigerador es el compresor. Si un frigorífico no está equipado con un compresor de buena calidad y tecnología no puede ser un buen frigorífico.
-
07/29/2023
Compresor Scroll Vs. Compresor rotativo para CA
El compresor scrollue inventado en 1905 por el francés Copeland. Creó la compañía Copeland en los Estados Unidos, donde se utilizan principalmente acondicionadores de aire de agua
-
01/08/2024
¿Por qué vibra el servomotor?
¿En qué casos vibrará un servomotor? ¿Qué pasa si el servomotor vibra? ¿Cómo podemos solucionar los problemas causados por la vibración? Este artículo explicará varias razones para esto.