Mejores selecciones
1/1
Schneider Transformador ABL6TS40U
$ 210 .00
Envío gratuito (excluidos los derechos de aduana y los impuestos) >
✔ En stock (Puede enviarse en 5-7 días)
(4.6) 5
Comentarios
Cantidad
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Main range of product
Phaseo Optimum
product or component type
Safety and isolation transformer
rated power in VA
400 VA
input voltage
230 V AC single phase, terminal(s): N-L1
400 V AC phase to phase, terminal(s): L1-L2
output voltage
230 V AC
secondary winding
Single
protective cover
Without
ambient air temperature for operation
-20...50 Celsius degrees
Complementary input voltage limits
207...253 V
360...440 V
network frequency limits
47...63 Hz
input voltage tolerance
+/- 15 V
efficiency
92 %
power dissipation in W
34.8 W
output sustained overvoltage
4 % (no load, hot state)
voltage drop at rated load
<= 0.7 %
no load losses
12.4 W
short-circuit voltage
0,0477
output protection type
Against overload, protection technology: external
Against overvoltage, protection technology: external
Against short-circuits, protection technology: external
connections - terminals
Screw type terminals for input connection, connection capacity: 5 x 4 mm^2AWG 11
Screw type terminals for input ground connection, connection capacity: 1 x 4 mm^2AWG 11
Screw type terminals for output connection, connection capacity: 2 x 4 mm^2AWG 11
marking
CE
fixing mode
By 4 screws, screw(s) D= 5.8 mm on horizontal panel with derating to 90 %
By 4 screws, screw(s) D= 5.8 mm on vertical panel, operating position: horizontal
By 4 screws, screw(s) D= 5.8 mm on vertical panel, operating position: vertical
operating altitude
3000 m
electrical insulation class
Class B
width
136 mm
height
140 mm
depth
120 mm
product weight
6.5 kg
Environment product certifications
UR
EAC
standards
UL 506
IP degree of protection
IP20
environmental characteristic
EMC conforming to EN 62041
Safety conforming to EN 61558-1
Safety conforming to EN 61558-2-6
protective treatment
TC
ambient air temperature for storage
-40...80 Celsius degrees
overvoltage category
Class I conforming to VDE 0106-1
dielectric strength
Between winding and ground
Between primary and secondary
Phaseo Optimum
product or component type
Safety and isolation transformer
rated power in VA
400 VA
input voltage
230 V AC single phase, terminal(s): N-L1
400 V AC phase to phase, terminal(s): L1-L2
output voltage
230 V AC
secondary winding
Single
protective cover
Without
ambient air temperature for operation
-20...50 Celsius degrees
Complementary input voltage limits
207...253 V
360...440 V
network frequency limits
47...63 Hz
input voltage tolerance
+/- 15 V
efficiency
92 %
power dissipation in W
34.8 W
output sustained overvoltage
4 % (no load, hot state)
voltage drop at rated load
<= 0.7 %
no load losses
12.4 W
short-circuit voltage
0,0477
output protection type
Against overload, protection technology: external
Against overvoltage, protection technology: external
Against short-circuits, protection technology: external
connections - terminals
Screw type terminals for input connection, connection capacity: 5 x 4 mm^2AWG 11
Screw type terminals for input ground connection, connection capacity: 1 x 4 mm^2AWG 11
Screw type terminals for output connection, connection capacity: 2 x 4 mm^2AWG 11
marking
CE
fixing mode
By 4 screws, screw(s) D= 5.8 mm on horizontal panel with derating to 90 %
By 4 screws, screw(s) D= 5.8 mm on vertical panel, operating position: horizontal
By 4 screws, screw(s) D= 5.8 mm on vertical panel, operating position: vertical
operating altitude
3000 m
electrical insulation class
Class B
width
136 mm
height
140 mm
depth
120 mm
product weight
6.5 kg
Environment product certifications
UR
EAC
standards
UL 506
IP degree of protection
IP20
environmental characteristic
EMC conforming to EN 62041
Safety conforming to EN 61558-1
Safety conforming to EN 61558-2-6
protective treatment
TC
ambient air temperature for storage
-40...80 Celsius degrees
overvoltage category
Class I conforming to VDE 0106-1
dielectric strength
Between winding and ground
Between primary and secondary
Schneider Transformador ABL6TS40U
$ 210 .00
Envío gratuito (excluidos los derechos de aduana y los impuestos) >
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
(4.6)
5
Comentarios
Cantidad
MOQ : 2
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
CHINT Transformador TDGC2J-3
US$117.50
GE Disyuntor FD160 3P 125A
US$519.23
Eaton Contactor DILM38-01C
US$215.38
Fuji Fusible CS5F-400
US$46.15
Pilz Relé 773300
US$415.38
UniOhm Resistor 1206W4J0200T5E
US$10.96
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Sanyo Denki Ventilador 9G0848G101
US$22.66
Copeland Compresor 3DK3R15ME-TFD-201
Contacta con nosotros
Midea Aire acondicionado KFR-35GW-BP3DN1Y-PA402(A2)
Contacta con nosotros
Rexroth Bomba de paletas PVQ51-1X/154-046RA15UUVB
Contacta con nosotros
PIZZATO Interruptor NA B022KP-SMKR18
US$576.92
Teco TAIAN VFD Frequency Converter L510-1P5-SH1-PP
Contacta con nosotros
Bristol Compresor H22J22BABCC
Contacta con nosotros
Bosch IC Integrated Circuit Chip BNO055
US$107.69