liquid type: most clean liquids or liquids with a small amount of suspended solids or bubbles
Flow rate range: two-way to more than 40 FPS (12 MPS)
Flow accuracy:
more than 50 mm (2""): ± 1% of reading or ±0.01 FPS (0.003 MPS), whichever is higher
25~50 mm (1~2""): ±1% of reading or ±0.04 FPS (0.012 MPS), whichever is higher
19 mm (¾"") and below: ±1% full scale
temperature accuracy:
absolute temperature: 0.25°C (0.45°F)
temperature difference: 0.1°C (0.18°F)
energy temperature range: 0~100°C (32~ 212°F)
Flow sensitivity: 0.001 FPS (0.0003 MPS)
Temperature: 0.025°C (0.05°F)
Repeatability: 0.5% of reading transmitter
Power requirements (AC): 95~264 Vac 47~63 Hz @ 17 VA maximum standard, 20~28 Vac 47~63 Hz @ 0.35 A maximum ("-24 VAC" model), 10~28 Vdc @ 5 W maximum Value ("-VDC" model)
Protection: automatic reset fuse, reverse polarity and transient suppression
display: two-line LCD, LED backlight; top row 18 mm (0.7"") high, 7 segments; bottom row 9 mm (0.35) "") High, 14-segment
icons: RUN, PROGRAM, RELAY1 (Relay 1), RELAY2 (Relay 2)
Flow rate indication: 8 positive numbers, 7 negative maximum values; automatic decimals, starting with zero Bit blanking
flow totalizer: 8-digit positive number, 7-digit negative maximum value (reset by keyboard keys, software, network command or instantaneous contact closure)
Shell NEMA 4 (IP65) structure: powder-coated aluminum, polycarbonate , Stainless steel, polyurethane, nickel-plated steel mounting bracket
size (electronic enclosure only): 152 (width) × 112 (height) × 56 (thickness) mm (6.0""×4.4""×2.2"")
Conduit hole: ( 2) ½ NPT female (1) ¾ NPT female
temperature: -40~85°C (-40~185°F)
RTD: Platinum 385,1000O, 3-wire
Flow rate range: two-way to more than 40 FPS (12 MPS)
Flow accuracy:
more than 50 mm (2""): ± 1% of reading or ±0.01 FPS (0.003 MPS), whichever is higher
25~50 mm (1~2""): ±1% of reading or ±0.04 FPS (0.012 MPS), whichever is higher
19 mm (¾"") and below: ±1% full scale
temperature accuracy:
absolute temperature: 0.25°C (0.45°F)
temperature difference: 0.1°C (0.18°F)
energy temperature range: 0~100°C (32~ 212°F)
Flow sensitivity: 0.001 FPS (0.0003 MPS)
Temperature: 0.025°C (0.05°F)
Repeatability: 0.5% of reading transmitter
Power requirements (AC): 95~264 Vac 47~63 Hz @ 17 VA maximum standard, 20~28 Vac 47~63 Hz @ 0.35 A maximum ("-24 VAC" model), 10~28 Vdc @ 5 W maximum Value ("-VDC" model)
Protection: automatic reset fuse, reverse polarity and transient suppression
display: two-line LCD, LED backlight; top row 18 mm (0.7"") high, 7 segments; bottom row 9 mm (0.35) "") High, 14-segment
icons: RUN, PROGRAM, RELAY1 (Relay 1), RELAY2 (Relay 2)
Flow rate indication: 8 positive numbers, 7 negative maximum values; automatic decimals, starting with zero Bit blanking
flow totalizer: 8-digit positive number, 7-digit negative maximum value (reset by keyboard keys, software, network command or instantaneous contact closure)
Shell NEMA 4 (IP65) structure: powder-coated aluminum, polycarbonate , Stainless steel, polyurethane, nickel-plated steel mounting bracket
size (electronic enclosure only): 152 (width) × 112 (height) × 56 (thickness) mm (6.0""×4.4""×2.2"")
Conduit hole: ( 2) ½ NPT female (1) ¾ NPT female
temperature: -40~85°C (-40~185°F)
RTD: Platinum 385,1000O, 3-wire
Hacer preguntas
(0/1,200)
- Consulta: ¿Puedo realizar un seguimiento de varios pedidos a la vez?
Responder: Sí, si tienes varios pedidos, puedes rastrearlos simultáneamente accediendo a la sección "Seguimiento de pedido" en nuestro sitio web. Ingresa los detalles necesarios para cada pedido y podrás monitorear su progreso en un solo lugar.
- Consulta: ¿Tiene una tabla de conversión de tallas para clientes internacionales?
Responder: Sí, proporcionamos tablas de conversión de tallas para clientes internacionales en nuestro sitio web. Estas tablas le ayudan a convertir tallas entre diferentes sistemas de medición, lo que garantiza que seleccione la talla adecuada para su región. Por lo general, se pueden encontrar en la descripción del producto o en la página de la guía de tallas.
- Consulta: ¿Cómo puedo comunicarme con el servicio de atención al cliente para obtener ayuda?
Responder: Puedes encontrar la información de contacto del servicio de atención al cliente en la parte inferior de la página web de la plataforma de comercio electrónico o en tu cuenta de usuario. Por lo general, las opciones incluyen chat en línea, línea directa de atención al cliente o correo electrónico. Nuestro equipo de atención al cliente responderá lo antes posible para brindarle asistencia.
Comentarios
- U
Usuario anónimo
25/11/2022
Omega Caudalímetro FDT-40E-VDC¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Omega Caudalímetro FDT-40E-VDC
No hay precio en este momento, puede solicitar una cotización
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
SYNCHROFLEX Belt T 10-1390
US$14.23
ULVAC Bomba de Vacío PMB2400D-MF2A2R4XXB1
Contacta con nosotros
Bosch Rexroth Válvula solenoide 4WE6E6X/EW230NZ45L
Contacta con nosotros
NSK Cojinete NJ 316 EM C3
US$167.31
Daikin Aire acondicionado FZFSP71AB
US$4230.75
Omron PLC CPM2A-40CDT1-D
Contacta con nosotros
Kompass Bomba de paletas PV2R13-76+25-FR
Contacta con nosotros
NSK Cojinete QJ 1021
US$363.46