JUMO Controlador de temperatura 702111/8-0001-23/221
$ 352 .60
(5) 1
Comentarios
Cantidad
MOQ : 1
Pagos
Description
Inputs and output:
Each device type has a universal analog input(for RTD temperature probe, thermocouple, current, voltage, resistance transmitter, resistance/potentiometer), a digital input and a switchable digital input/output. With the exception of type 702110, where the basic type has one relay output(N/O contact), all remaining types are equipped with two relay outputs(N/O contacts). ¡El digital inputs are provided to connect a potential-free contact. ¡El digital output provides a logic signal 0/14 V.
Additional relay outputs(N/O contacts), the logic outputs(0/14V), PhotoMOS® relay out puts1 and an analog output (0(2) to 10 V /0(4) to 20 mA) are available as options.Certain inputs and outputs cannot be used si multaneously (see notes in the connection di agram).
Signal allocation via selectors:
¡El input signals of the analog input and the digital inputs are available for further use in the device in so-called selectors (analog selector, digital selector). ¡El trigger signals for the an alog output and the digital outputs are also as signed via selectors, which allows for flexiblesignal/function assignment.
Interfaces:
¡El device is equipped with a USB device in terface (micro-B socket on the rear of the de vice) that is provided for the connection to a PC and is only used for the setup program.Thereby the device is powered via the USB in terface. As a result, no mains supply is re quired during the configuration. A RS485 interface is also available as an op tion which is provided for communication with a Modbus master (Modbus-RTU operating mode). ¡El master can transmit up to two an alog values and two binary values to the de vice that are used there as external input signals. Two analog flags and two digital flags (binary) are also available.
An Ethernet interface is also available as an option, which supports the Modbus-TCP and Modbus-RTU/ASCII via TCP operating modes. This allows the same parameters and process values to be transferred as via the RS485 interface.
Voltage supply:
¡El device is available in two voltage supply variants: AC 110 to 240 V or AC/ DC 20 to 30 V, each 48 to 63 Hz.
Electrical connection:
¡El electrical connection saves time by using practical spring-cage terminals (Push-In tech nology). Controller types and structures:¡El device is a one-channel controller that can be configured as a two-state controller, three-state controller, three-step controller, and continuous controller. Depending on the controller type, different controller structures can be prescribed (P, I, PD, PI, PID) using ad justable controller parameters. ¡El controller supports two switchable parameter blocks. ¡El controller setpoint can also be switched. Up to four setpoint values can be entered. ¡El selection of the active setpoint value is con trolled by two binary signals.
Autotuning:
Autotuning (oscillation method or step re sponse method) also makes it possible for the controller to be matched to the control process by a user who is not a control technology ex pert. ¡El way the control process reacts to changes in the actuating variable is evaluated in the process and certain controller parame ters are calculated.
Ramp function:
¡El ramp function is used for a constant change of setpoint value up to the ramp limit value (entered setpoint value). A rising or a falling edge arises depending on the actual value at the time of the ramp start. ¡El slope is defined via two adjustable gradients (up ward, downward). ¡El ramp function is con trolled via binary signals (start, brake, stop).
Program controller:
¡El controller can also be operated as a pro gram controller. Using a program editor, the user can create a program for a setpoint value and four operating contacts with up to 24 pro gram sections. This program is processed by the program generator. Details such as pro gram start, program repeat and the type of set point value change (jump or ramp) are specified by the configuration of the program generator.
Limit value monitoring:
¡El device is equipped with four limit value monitoring functions, each with eight configu rable alarm functions. Any analog signal from
a selector is selected as the value to be moni tored. An absolute value or a value that de pends on an additional analog signal serves as the limit value. Special functions such as switch-on/switch-off delay, pulse function, alarm suppression in the switch-on phase or in case of a parameter change, alarm latch and
lock with acknowledgment are available. With the limit value monitoring function, extensive alarm and limit value functions can be imple mented.
Digital controller signals:
Up to four digital control signals can be config ured using this function. In this process, the control signal is formed either by an AND/OR/ XOR link of up to three selectable binary sig nals. Or a single binary signal serves as an input signal and is output as a pulse-shaped signal, as a delayed signal, as a so-called wiper sig nal, or as an edge-triggered signal. In the latter case the rising or falling edge of the binary sig nal is detected, and the output signal is acti vated for the duration of the sampling interval. ¡El output signal can be inverted in all speci fied cases.
Timer:
After the timer is started, a signal is output for the duration of the timer running time; this sig nal is invertible. It is also possible to start the timer after the lead time has elapsed or after reaching a tolerance limit. A timer end signal can be output after the timer has elapsed (limit by time or acknowledgement). ¡El timer can be used to implement various, time-dependent functions like time-limited control or setpoint changeover or a time-de layed control.
Service counter:
¡El device is equipped with a counter function that can be used as a service counter. To this end, either the switching frequency of a binary signal is counted or its duty cycle is deter mined. When the set limit value is reached, a binary signal is activated that needs to be ac knowledged. In addition, an operating hours counter is
available that determines the device's opera tion time.
Math and logic function:
¡El optional math and logic function (extra code) can be used to link analog or binary val ues. Up to four freely configurable maths or logic formulae can be created using the setup program. ¡El results are available in the ana log or digital selector for further use.
Individual user level:
¡El individually configurable user level con tains up to 16 editable configuration parame ters. ¡El parameters are selected in the setup program.
Setup program:
¡El setup program provides the user with an easy and comfortable way to configure the de vice using a PC. You can use it to create and edit data records, transfer them to the device, and extract them from it. ¡El data can be stored and printed. In addition, the user can easily create and print out a connection dia gram that shows the current terminal assign ment of the device. Startup: the startup function is for recording process variables during startup (max. 24 hours). ¡El recorded diagrams are available on the PC and can, for example, be used for system documentation.Online data: ¡El device's current process variables are shown in a separate window. Program editor: In addition to the program ed itor inside the device, the setup program also provides the option to create a setpoint value
program.
Customer-specific linearization:
Sensor signals with special characteristic line characteristics can also be used through cus tomer-specific linearization. Programming is carried out in the setup program on the basis of a value table with up to 40 value pairs or through a formula (4th order polynomial).
Structured text:
¡El user has the option to create his/her own
application using the "Structured text" option
(extra code).
¡El application with the ST editor, which is part of the setup program, is created in the PLC programming language "Structured text". ¡El finished application is transmitted to the device and continuously processed there. There are online-debugger functions available in the ST editor for testing and troubleshoot ing.
Up to 10 stored text messages can be dis played via the ST code depending on the application.
Las personas que compraron este artículo también vieron
E+E Transmisor EE65VC5K200
US$897.66
HANNA Medidor de conductividad HI9033
US$1896.92
OMEGA Manómetro DPG101-200A
US$757.70
Los clientes ven con frecuencia
Carel Válvula de expansión E6VB2ASV00
US$839.00
Mitsubishi Compresor RE277NRAMT
US$389.00
Togami Contactor CLK-25J3
US$79.00
SAND Transmisor PT124B-35MPa-M14-150/470
US$312.50
MAC Válvula solenoide 55B-14-PI-501JB
US$261.54
Sanyo Compresor C-L105M83
US$2884.62
Honeywell Sensor HOA0870-N51
US$6.16
KOMPASS Bomba de pistón PV270A3LM1A
US$3418.46
Publicaciones relacionadas recientes
-
12/05/2023
Principios y diferencias de los transmisores de 2, 3 y 4 hilos
Los transmisores de 2, 3 y 4 hilos se refieren a transmisores cuyas salidas son señales analógicas de corriente CC.
-
03/10/2024
Todo lo que debe saber sobre el embrague magnético del compresor de CA del coche
Este artículo presenta los componentes del embrague magnético del compresor y su principio de funcionamiento, así como varios parámetros importantes. Además, también le brindamos algunas experiencias sobre cómo lidiar con la quema de los embragues del compresor del aire acondicionado.
-
01/08/2024
¿Por qué vibra el servomotor?
¿En qué casos vibrará un servomotor? ¿Qué pasa si el servomotor vibra? ¿Cómo podemos solucionar los problemas causados por la vibración? Este artículo explicará varias razones para esto.
-
02/17/2024
Método de cableado del relé PTC de nevera
El relé PTC (coeficiente de temperatura positivo) está conectado directamente en serie con el devanado secundario (devanado de arranque) y en paralelo con el devanado principal del motor.
-
11/18/2023
Transmisores Rosemount Series 1151, 2088, 2051, 3051CA, 3051S y sus diferencias
El transmisor de presión Rosemount es un tipo de transmisor de presión general. Está fabricado según la ley de inducción electromagnética y la norma JB/T9248-1999.
-
08/08/2023
Método de cálculo del peso por metro de tubo de cobre para aire acondicionado
Método de cálculo del peso por metro de tubería de cobre para aire acondicionado.
-
08/04/2023
Aire acondicionado Mitsubishi vs Panasonic
El verano es tan difícil de pasar que las personas sin aire acondicionado son como peces fuera del agua. Es fundamental elegir un buen aire acondicionado.
-
06/27/2023
Principio de funcionamiento del compresor frigorífico, esquema eléctrico, estructura
El componente principal del refrigerador es el compresor. Si un frigorífico no está equipado con un compresor de buena calidad y tecnología no puede ser un buen frigorífico.
-
05/12/2022
Reparación de averías en servoaccionamientos Ultra3000
Hemos enumerado las fallas comunes y los métodos de reparación de los servovariadores Ultra3000; si necesita reemplazar el equipo, le brindamos Servoaccionamiento Allen Bradley Rockwell.
-
07/29/2023
Compresor Scroll Vs. Compresor rotativo para CA
El compresor scrollue inventado en 1905 por el francés Copeland. Creó la compañía Copeland en los Estados Unidos, donde se utilizan principalmente acondicionadores de aire de agua