Mejores selecciones
Festo Cilindro de aire DNC-63-200-PPV-A-KP
$ 265 .38
(5) 1
Comentarios
Cantidad
MOQ : 2
Pagos
Maritime classification: See certificate
Stroke: 3 mm - 2000 mm
Piston diameter: 63 mm
Type code: DNC
Based on norm: ISO 15552
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Design: Piston: Piston rod: Profile barrel
Position sensing: For proximity sensor: None
Variants: Temperature range -40 to 80 Celsius Degree: With anti-twist protection: Piston rod with external hexagon: Continuous, hollow piston rod: Piston rod at one end: Monostable pneumatic valve, fitted on right, piston rod extended when not actuated: Extended piston rod: With end-position locking at both ends: Monostable pneumatic valve, mounted on right, piston rod retracted when not actuated: Bistable pneumatic valve, fitted on right, piston rod retracted when not actuated: With rear end-position locking: Through piston rod: Increased service life: Monostable pneumatic valve, mounted on left, piston rod retracted when not actuated: Clamping unit on the piston rod: Internal thread on piston rod: Special thread on piston rod: Bistable pneumatic valve, fitted on left, piston rod retracted when not actuated: High corrosion protection: Low friction: Heat-resistant seals max. 120Celsius Degree: Monostable pneumatic valve, fitted on left, piston rod extended when not actuated: Constant, slow movement: Extended external thread piston rod: With front end-position locking: Dust protection
Protection against torsion/guide: Square piston rod
Operating pressure: 0.15 bar - 12 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 1 (ATEX): Zone 22 (ATEX): Zone 21 (ATEX): Zone 2 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 2 - Moderate corrosion stress: 3 - High corrosion stress
Ambient temperature: -40 to 120 Celsius Degree
Impact energy in the end positions: 0.5 J
Max. torque for protection against rotation: 1.5 Nm
Theoretical force at 6 bar, retracting: 1682 N
Theoretical force at 6 bar, advancing: 1682 N - 1870 N
Type of mounting: With internal thread: With accessories
Pneumatic connection: G3/8
Note on materials: RoHS-compliant
Cover material: Coated: Die-cast aluminum
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Stroke: 3 mm - 2000 mm
Piston diameter: 63 mm
Type code: DNC
Based on norm: ISO 15552
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Design: Piston: Piston rod: Profile barrel
Position sensing: For proximity sensor: None
Variants: Temperature range -40 to 80 Celsius Degree: With anti-twist protection: Piston rod with external hexagon: Continuous, hollow piston rod: Piston rod at one end: Monostable pneumatic valve, fitted on right, piston rod extended when not actuated: Extended piston rod: With end-position locking at both ends: Monostable pneumatic valve, mounted on right, piston rod retracted when not actuated: Bistable pneumatic valve, fitted on right, piston rod retracted when not actuated: With rear end-position locking: Through piston rod: Increased service life: Monostable pneumatic valve, mounted on left, piston rod retracted when not actuated: Clamping unit on the piston rod: Internal thread on piston rod: Special thread on piston rod: Bistable pneumatic valve, fitted on left, piston rod retracted when not actuated: High corrosion protection: Low friction: Heat-resistant seals max. 120Celsius Degree: Monostable pneumatic valve, fitted on left, piston rod extended when not actuated: Constant, slow movement: Extended external thread piston rod: With front end-position locking: Dust protection
Protection against torsion/guide: Square piston rod
Operating pressure: 0.15 bar - 12 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 1 (ATEX): Zone 22 (ATEX): Zone 21 (ATEX): Zone 2 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 2 - Moderate corrosion stress: 3 - High corrosion stress
Ambient temperature: -40 to 120 Celsius Degree
Impact energy in the end positions: 0.5 J
Max. torque for protection against rotation: 1.5 Nm
Theoretical force at 6 bar, retracting: 1682 N
Theoretical force at 6 bar, advancing: 1682 N - 1870 N
Type of mounting: With internal thread: With accessories
Pneumatic connection: G3/8
Note on materials: RoHS-compliant
Cover material: Coated: Die-cast aluminum
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Las personas que compraron este artículo también vieron
Festo Cilindro de aire ADVU-80-60-P-A
US$533.17
Festo Cilindro de aire ADN-125-30-A-P-A
US$523.08
AirTAC Cilindro de aire SC63X230
US$46.15
Festo Cilindro de aire DNC-50-125-PPV-A-KP
US$1072.95
HENGSTLER Codificador RI32-O/720AR.11KB
US$343.15
SMC Válvula solenoide VG342R-2D-04
US$211.54
Belimo Actuator SM24A
US$317.16
SMC Válvula proporcional ITV3031-31N2S4
US$604.81
Los clientes ven con frecuencia
Carel Válvula de expansión E6VB2ASV00
US$839.00
Mitsubishi Compresor RE277NRAMT
US$389.00
Togami Contactor CLK-25J3
US$79.00
Contrinex Sensor DW-HD-603-M18-411
US$100.00
Publicaciones relacionadas recientes
-
05/11/2022
Reparación de averías en servoaccionamientos Ultra3000
Hemos enumerado las fallas comunes y los métodos de reparación de los servovariadores Ultra3000; si necesita reemplazar el equipo, le brindamos Servoaccionamiento Allen Bradley Rockwell.
-
02/17/2024
Método de cableado del relé PTC de nevera
El relé PTC (coeficiente de temperatura positivo) está conectado directamente en serie con el devanado secundario (devanado de arranque) y en paralelo con el devanado principal del motor.
-
03/10/2024
Todo lo que debe saber sobre el embrague magnético del compresor de CA del coche
Este artículo presenta los componentes del embrague magnético del compresor y su principio de funcionamiento, así como varios parámetros importantes. Además, también le brindamos algunas experiencias sobre cómo lidiar con la quema de los embragues del compresor del aire acondicionado.
-
11/18/2023
Transmisores Rosemount Series 1151, 2088, 2051, 3051CA, 3051S y sus diferencias
El transmisor de presión Rosemount es un tipo de transmisor de presión general. Está fabricado según la ley de inducción electromagnética y la norma JB/T9248-1999.
-
06/27/2023
Principio de funcionamiento del compresor frigorífico, esquema eléctrico, estructura
El componente principal del refrigerador es el compresor. Si un frigorífico no está equipado con un compresor de buena calidad y tecnología no puede ser un buen frigorífico.
-
12/05/2023
Principios y diferencias de los transmisores de 2, 3 y 4 hilos
Los transmisores de 2, 3 y 4 hilos se refieren a transmisores cuyas salidas son señales analógicas de corriente CC.
-
07/29/2023
Compresor Scroll Vs. Compresor rotativo para CA
El compresor scrollue inventado en 1905 por el francés Copeland. Creó la compañía Copeland en los Estados Unidos, donde se utilizan principalmente acondicionadores de aire de agua
-
08/08/2023
Método de cálculo del peso por metro de tubo de cobre para aire acondicionado
Método de cálculo del peso por metro de tubería de cobre para aire acondicionado.
-
08/04/2023
Aire acondicionado Mitsubishi vs Panasonic
El verano es tan difícil de pasar que las personas sin aire acondicionado son como peces fuera del agua. Es fundamental elegir un buen aire acondicionado.
-
01/07/2024
¿Por qué vibra el servomotor?
¿En qué casos vibrará un servomotor? ¿Qué pasa si el servomotor vibra? ¿Cómo podemos solucionar los problemas causados por la vibración? Este artículo explicará varias razones para esto.