Service:Homogeneous liquids that do not contain air bubbles capable of ultrasonic wave propagation.
Inputs:Lemo connector cable from sensors.
Range:0.33 to 65.62 ft/s (0.1 to 20 m/s).
Display:240 x 64 pixel graphic display, high contrast black on white with backlight; Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5.2" W x 1.5" H (132.1 x 38.1 mm).
Accuracy:± 0.5 to 2% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and Pipe ID > 3 in (75 mm). ± 3% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and Pipe ID in range 0.5 to 3 in (13 to 75 mm). ± 6% of flow reading for flow rate < 0.66 ft/s (0.2 m/s).
Power Requirements:9 to 24 VDC; (1) 5-Cell NiMH battery, internal, factory replaceable (continuous operation time: 20 hours with back light and output off); (recharging time: 6.5 hours, power adapter used).
Power Consumption:10.5 W.
Power Adapter:110/240 VAC adapter; UK,US, European adapters included.
Temperature Limits:-4 to 275°F (-20 to 135°C).
Outputs:Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 O max; Pulse: 1 opto-isolated MOSFET relay, 150 mA max, 500 pps max, 200 Hz max.
Serial Communications:USB; RS-232.
Enclosure Rating:Transducers: IP51; Carrying Case: IP67; Converter: IP54.
Materials:Flame retardant injection molded ABS plastic.
Repeatability:±0.5 % of measured value or ±0.066 ft/s (0.02 m/s).
Electrical Connections:Multi-pin Lemo plugs.
Turbidity:<3% by volume of particulate content.
Permissible Air Content:<3% by volume.
Response Time:<500 ms.
Weight:Unit without accessories: 2.30 lb (1.06 kg); Unit with accessories in carrying case: 14.40 lb (6.52 kg).
Inputs:Lemo connector cable from sensors.
Range:0.33 to 65.62 ft/s (0.1 to 20 m/s).
Display:240 x 64 pixel graphic display, high contrast black on white with backlight; Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5.2" W x 1.5" H (132.1 x 38.1 mm).
Accuracy:± 0.5 to 2% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and Pipe ID > 3 in (75 mm). ± 3% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and Pipe ID in range 0.5 to 3 in (13 to 75 mm). ± 6% of flow reading for flow rate < 0.66 ft/s (0.2 m/s).
Power Requirements:9 to 24 VDC; (1) 5-Cell NiMH battery, internal, factory replaceable (continuous operation time: 20 hours with back light and output off); (recharging time: 6.5 hours, power adapter used).
Power Consumption:10.5 W.
Power Adapter:110/240 VAC adapter; UK,US, European adapters included.
Temperature Limits:-4 to 275°F (-20 to 135°C).
Outputs:Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 O max; Pulse: 1 opto-isolated MOSFET relay, 150 mA max, 500 pps max, 200 Hz max.
Serial Communications:USB; RS-232.
Enclosure Rating:Transducers: IP51; Carrying Case: IP67; Converter: IP54.
Materials:Flame retardant injection molded ABS plastic.
Repeatability:±0.5 % of measured value or ±0.066 ft/s (0.02 m/s).
Electrical Connections:Multi-pin Lemo plugs.
Turbidity:<3% by volume of particulate content.
Permissible Air Content:<3% by volume.
Response Time:<500 ms.
Weight:Unit without accessories: 2.30 lb (1.06 kg); Unit with accessories in carrying case: 14.40 lb (6.52 kg).
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo cancelar o modificar un pedido?
Responder: Si necesita cancelar o modificar un pedido, comuníquese con nuestro equipo de atención al cliente lo antes posible. Haremos todo lo posible para atender su solicitud según el estado y la viabilidad del pedido.
- Consulta: ¿Cómo puedo comparar precios y reseñas de productos similares?
Responder: En la página de listado de productos, puede ver los precios y calificaciones de diferentes artículos simultáneamente. También puede utilizar herramientas de filtrado para ordenar los productos por precio o calificación, lo que facilita una mejor comparación y selección.
- Consulta: ¿Cómo puedo participar en promociones o sorteos organizados por vendedores?
Responder: Regularmente realizamos eventos promocionales, obsequios y actividades de obsequios. Puede seguir nuestros anuncios oficiales, correos electrónicos o canales de redes sociales para obtener información sobre cómo participar y los detalles de estas actividades y unirse.
Comentarios
- U
Usuario anónimo
25/11/2022
Dwyer Caudalímetro PUF-1003¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Dwyer Caudalímetro PUF-1003
No hay precio en este momento, puede solicitar una cotización
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Lika Codificador I58-H-1024ZCZ46
Contacta con nosotros
Neuma Válvula solenoide NV-ISO1-32-D2
Contacta con nosotros
Copeland Compresor ZPD91KCE-TFV-600
Contacta con nosotros
Leynow Bomba de Vacío LD0030C
US$3576.92
CKD Válvula solenoide 4KA229-L
Contacta con nosotros
Eaton Contactor C25FRD150J
Contacta con nosotros
Banner Sensor S18SP6DQ
US$75.00
ULVAC Bomba de Vacío VS750A-W-02222-492231135
Contacta con nosotros