Mejores selecciones
1/1
Chint Disyuntor NXMLE-630S/4300
No hay precio en este momento, puede solicitar una cotización
¡El Chint Circuit Breaker es de alta calidad!
Residual current operating characteristics AC type, A type
¡El rated residual operating current IΔn (ma) (2p, 3P+N, 4P) is not adjustable in single gear,
and it is 50/100/200/300/500/1000 without delay
(2P, 3P+N, 4P) single gear is not adjustable, delay type 50/100/200/300/500/1000
¡El rated residual inoperative current IΔno (ma) is 0.5IΔn.
Maximum breaking time (s) of non-delay 5IΔn ≤ 0.04
¡El main function of residual current operated circuit breaker series is to provide indirect contact
protection for fatal personal electric shock, and to provide protection for electrical fire caused by
ground fault current, such as insulation damage. It also provides protection for overload, short
circuit and undervoltage of the line, and can also be used for infrequent switching of the line.
Grade of shell frame: 125A, 160A, 250A, 400A, 630A, 800A
¡El rated working voltage Ue(AC): AC 230V/240V(1P+N, 2P),
AC 400V/415V(3P, 3P+N,4P)
Code of breaking capacity: s and h
Number of poles: 1P+N, 2P, 3P, 3P+N, 4P 1P+N, 2P is only applicable to shell products of 250A and below)
Installation mode: fixed type and plug-in type
NXMLE-125 H P/3 300 2
NXMLE: residual current operated circuit breaker
125: current level code of shell frame 125A 160A 250A 400A 630A 800A
H: breaking capacity code s: (ac230v/ac240v): 36ka (ac400v/ac415v: 25ka
H:(AC230V/AC240V):50kA(AC400V/AC415V):36kA
P: operation mode code No code handle direct operation P electric operation Z: rotating handle operation
3: Pole number code 1P+N 2P 3P 3P+N 4P
300: Trip Method and Internal Attachment Code
2. Use code No code: for distribution protection 2: for motor protection 3: for generator protection
Residual current operating characteristics AC type, A type
¡El rated residual operating current IΔn (ma) (2p, 3P+N, 4P) is not adjustable in single gear,
and it is 50/100/200/300/500/1000 without delay
(2P, 3P+N, 4P) single gear is not adjustable, delay type 50/100/200/300/500/1000
¡El rated residual inoperative current IΔno (ma) is 0.5IΔn.
Maximum breaking time (s) of non-delay 5IΔn ≤ 0.04
¡El main function of residual current operated circuit breaker series is to provide indirect contact
protection for fatal personal electric shock, and to provide protection for electrical fire caused by
ground fault current, such as insulation damage. It also provides protection for overload, short
circuit and undervoltage of the line, and can also be used for infrequent switching of the line.
Grade of shell frame: 125A, 160A, 250A, 400A, 630A, 800A
¡El rated working voltage Ue(AC): AC 230V/240V(1P+N, 2P),
AC 400V/415V(3P, 3P+N,4P)
Code of breaking capacity: s and h
Number of poles: 1P+N, 2P, 3P, 3P+N, 4P 1P+N, 2P is only applicable to shell products of 250A and below)
Installation mode: fixed type and plug-in type
NXMLE-125 H P/3 300 2
NXMLE: residual current operated circuit breaker
125: current level code of shell frame 125A 160A 250A 400A 630A 800A
H: breaking capacity code s: (ac230v/ac240v): 36ka (ac400v/ac415v: 25ka
H:(AC230V/AC240V):50kA(AC400V/AC415V):36kA
P: operation mode code No code handle direct operation P electric operation Z: rotating handle operation
3: Pole number code 1P+N 2P 3P 3P+N 4P
300: Trip Method and Internal Attachment Code
2. Use code No code: for distribution protection 2: for motor protection 3: for generator protection
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo filtrar productos por rango de precios?
Responder: En la página de listado de productos, puede utilizar la herramienta de filtrado de precios para establecer el rango de precios deseado. El sistema mostrará los productos que cumplan con sus criterios, ayudándole a encontrar los artículos adecuados rápidamente.
- Consulta: ¿Cómo puedo consultar el estado del inventario de un producto?
Responder: En la página de detalles del producto, puede verificar el estado del stock del artículo. Si un producto está temporalmente agotado, lo repondremos lo antes posible o brindaremos una opción de pedido anticipado.
- Consulta: ¿Cómo puedo comprobar el estado de mi reembolso?
Responder: Para comprobar el estado de su reembolso, puede ponerse en contacto con nuestro equipo de atención al cliente y proporcionarles los detalles necesarios, como su número de pedido y solicitud de reembolso. Le ayudarán a seguir el progreso de su reembolso.
Comentarios
- U
Usuario anónimo
25/11/2022
Chint Disyuntor NXMLE-630S/4300¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Chint Disyuntor NXMLE-630S/4300
No hay precio en este momento, puede solicitar una cotización
Las personas que compraron este artículo también vieron
EATON Transformador DTZ4
US$1183.04
Siemens Contactor 3RT2327-1AP60
US$192.31
ABB Fusible OFAF000H10
US$47.14
JOKAB Relé 2TLA010033R1000
US$552.00
Panasonic Resistor EXB-Q16P222J
US$1.15
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
UniOhm Resistor 0.5W22K
US$5.77
Parker Válvula proporcional TEA050EW09A2NXWJ22
Contacta con nosotros
SAND Transmisor PT2326-M20-185Bar-1~5
Contacta con nosotros
Copeland Compresor AFE10C4U-IAZ-201
Contacta con nosotros
NTN Cojinete AN02
US$3.05
Copeland Compresor KATA-0151-TAC-8R0
Contacta con nosotros
WECO Cortina de luz WECO-957M71-AC220-A
US$326.92
Ferraz Shawmut Fusible D73GB60V500TF
US$230.77
VOGEL Reduction Drive Caja de cambios Reductor de velocidad VGE60-L2-28
Contacta con nosotros

