Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 32 |
| Número de polos | 2 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 27...32 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S0 for motor protection, CLASS 10 A-release
27...32 A N-release 400 A Spring-type terminal Standard switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S0
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 13.25?W
at AC in hot operating state per pole 4.4?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
27?...?32?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 32?A
operating current
at AC-3
at 400 V rated value 32?A
operating power
at AC-3
at 230 V rated value 7?500?W
at 400 V rated value 15?000?W
at 500 V rated value 18?500?W
at 690 V rated value 30?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 25?kA
at 500 V rated value 5?kA
at 690 V rated value 2?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 55?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 4?kA
response value current
of instantaneous short-circuit trip unit 400?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 32?A
at 600 V rated value 32?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 2?hp
at 230 V rated value 5?hp
for three-phase AC motor
at 200/208 V rated value 7.5?hp
at 220/230 V rated value 10?hp
at 460/480 V rated value 20?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 400 V gL/gG 63 A
at 500 V gL/gG 63 A
at 690 V gL/gG 63 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 119?mm
width 45?mm
depth 97?mm
Circuit breaker size S0 for motor protection, CLASS 10 A-release
27...32 A N-release 400 A Spring-type terminal Standard switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S0
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 13.25?W
at AC in hot operating state per pole 4.4?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
27?...?32?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 32?A
operating current
at AC-3
at 400 V rated value 32?A
operating power
at AC-3
at 230 V rated value 7?500?W
at 400 V rated value 15?000?W
at 500 V rated value 18?500?W
at 690 V rated value 30?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 25?kA
at 500 V rated value 5?kA
at 690 V rated value 2?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 55?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 4?kA
response value current
of instantaneous short-circuit trip unit 400?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 32?A
at 600 V rated value 32?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 2?hp
at 230 V rated value 5?hp
for three-phase AC motor
at 200/208 V rated value 7.5?hp
at 220/230 V rated value 10?hp
at 460/480 V rated value 20?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 400 V gL/gG 63 A
at 500 V gL/gG 63 A
at 690 V gL/gG 63 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 119?mm
width 45?mm
depth 97?mm
Hacer preguntas
(0/1,200)
- Consulta: Cuanto tiempo tarda el envio?
Responder: El tiempo de envío depende del método de envío que elijas y del destino. Los tiempos de entrega estimados generalmente se proporcionan durante el proceso de pago.
- Consulta: ¿Cómo puedo verificar la certificación de seguridad o la información de cumplimiento de un producto?
Responder: Para productos que requieren certificación o cumplimiento de seguridad, proporcionamos información relevante en la página de detalles del producto. Puede consultar las etiquetas de certificación o descripciones para asegurarse de que el producto cumpla con los estándares y regulaciones pertinentes.
- Consulta: ¿Cómo me registro como miembro y qué privilegios tienen los miembros?
Responder: Registrarse como miembro es muy simple; solo necesita proporcionar cierta información básica. Los miembros pueden disfrutar de actividades promocionales exclusivas, puntos de recompensa, pago rápido y privilegios exclusivos de servicio al cliente.
Comentarios
- D
Damon Schoen
12/10/2025
Siemens Disyuntor 3RV2021-4EA20Always on the mark.ÚtilNo ayuda - D
David Walker
22/09/2025
Siemens Disyuntor 3RV2021-4EA20That's great, I've found what I was looking for.ÚtilNo ayuda - T
Tony Rodriguez
08/05/2025
Siemens Disyuntor 3RV2021-4EA20Fantastic helpÚtilNo ayuda - A
Andrea
07/09/2024
Siemens Disyuntor 3RV2021-4EA20I urgently need this sample for experimentation, it’s goodÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2021-4EA20¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2021-4EA20
$ 428 .33
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Fuji Disyuntor BC63E1CG-1P002
US$46.54
Fuji Disyuntor EG103F-3P100
US$103.85
Eaton Moeller Disyuntor HKW70K
US$3125.00
TRIAD Transformador F-143XP
US$38.45
Panasonic Contactor AECN11012
US$34.62
Ferraz Shawmut Fusible FR14GR69V2
US$32.69
CRYDOM Relé CSW2460
US$103.85
UniOhm Resistor 1206W4F390KT5E
US$21.15
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
SMC Válvula proporcional ITV2090-01F2CL5
Contacta con nosotros
Bristol Compresor H21J29BABCR
Contacta con nosotros
Littelfuse Fusible FLM9
US$18.40
STYLE Ventilador ZS15D15-W
US$141.54
YUKEN Bomba de paletas PVR50-F-T51-RLL-3180
Contacta con nosotros
Copeland Compresor 3DFDF40KE-TFD-201
Contacta con nosotros