Tipo | 3RV1 |
Tipo de disyuntor | Motor Protection Circuit Breakers |
Corriente nominal | 0.16 |
Número de polos | 2 pole |
Rango de ajuste para disparadores de sobrecarga térmica | 0.11...0.16 A |
Adecuado para motores de inducción con P | 0.04 kW |
Liberaciones instantáneas de sobrecorriente | 2.1 A |
Short-circuit breaking capacidad | 100 kA |
Peso approx. | 0.233 kg |
¡El Siemens Circuit Breaker es de alta calidad!
product brand nameSIRIUS
product designation circuit breaker
design of the product for motor protection
General technical data
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
surge voltage resistance rated value 6 000 V
protection class IP on the front IP20
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typica l100 000
continuous current rated value 0.16 A
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation-20 - +60 degrees centigrade
uring storage-50 - +80 degrees centigrade
during transport-50 - +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.11 - 0.16 A
operating voltage rated value 690 V at AC-3 rated value maximum 690 V
operating current at AC-3 at 400 V rated value 0.16 A
operating power at AC-3 at 400 V rated value 0.04 kW
operating frequency at AC-3 maximum 15 1/h
Auxiliary circuit
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No phase failure detection Yes
trip classCLASS 10
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
Short-circuit protection
design of the overcurrent release and short-circuit release thermomagnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
height 90 mm width 45 mm depth 81 mm
required spacing with side-by-side mounting
backwards 0 mm at the side 0 mm
type of electrical connection for main current circuit spring-loaded terminals
for auxiliary and control current circuit spring-loaded terminals
arrangement of electrical connectors for main current circuit front side
type of connectable conductor cross-sections
for main contacts solid 2x (0.25 - 2.5 mm?)
finely stranded with core end processing 2x (0.25 - 1.5 mm?)
finely stranded without core endprocessing 2x (0.25 - 2.5 mm?)
at AWG conductors for main contacts 2x (24 - 14)
product brand nameSIRIUS
product designation circuit breaker
design of the product for motor protection
General technical data
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
surge voltage resistance rated value 6 000 V
protection class IP on the front IP20
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typica l100 000
continuous current rated value 0.16 A
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation-20 - +60 degrees centigrade
uring storage-50 - +80 degrees centigrade
during transport-50 - +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.11 - 0.16 A
operating voltage rated value 690 V at AC-3 rated value maximum 690 V
operating current at AC-3 at 400 V rated value 0.16 A
operating power at AC-3 at 400 V rated value 0.04 kW
operating frequency at AC-3 maximum 15 1/h
Auxiliary circuit
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No phase failure detection Yes
trip classCLASS 10
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
Short-circuit protection
design of the overcurrent release and short-circuit release thermomagnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
height 90 mm width 45 mm depth 81 mm
required spacing with side-by-side mounting
backwards 0 mm at the side 0 mm
type of electrical connection for main current circuit spring-loaded terminals
for auxiliary and control current circuit spring-loaded terminals
arrangement of electrical connectors for main current circuit front side
type of connectable conductor cross-sections
for main contacts solid 2x (0.25 - 2.5 mm?)
finely stranded with core end processing 2x (0.25 - 1.5 mm?)
finely stranded without core endprocessing 2x (0.25 - 2.5 mm?)
at AWG conductors for main contacts 2x (24 - 14)
Las personas que compraron este artículo también vieron
Siemens Disyuntor 3RV1021-4BA10
US$322.00
GE Disyuntor MPD41W10
US$8653.85
Schneider Disyuntor LS8F18320G
US$250.00
Schneider Disyuntor LV510337
US$875.00
Siemens Transformador MT0350B
US$249.07
Shilin Contactor S-P40T 24V
US$42.31
SANYOU Relé SRG-S-105DM-F
US$1.31
EBG Resistor LXP-35-300R
US$5.00
Los clientes ven con frecuencia
Carel Válvula de expansión E6VB2ASV00
US$839.00
Mitsubishi Compresor RE277NRAMT
US$389.00
Togami Contactor CLK-25J3
US$79.00
AirTAC Cilindro de aire MARU32X10S
US$46.54
SMC Válvula solenoide SY5120-5LNZ-C6
US$84.53
KCL Bomba de paletas VQ25-47-F-RLR-01
US$3418.46
TYCO Relé T7CS5D-12
US$17.31
Publicaciones relacionadas recientes
-
05/12/2022
Reparación de averías en servoaccionamientos Ultra3000
Hemos enumerado las fallas comunes y los métodos de reparación de los servovariadores Ultra3000; si necesita reemplazar el equipo, le brindamos Servoaccionamiento Allen Bradley Rockwell.
-
11/18/2023
Transmisores Rosemount Series 1151, 2088, 2051, 3051CA, 3051S y sus diferencias
El transmisor de presión Rosemount es un tipo de transmisor de presión general. Está fabricado según la ley de inducción electromagnética y la norma JB/T9248-1999.
-
03/10/2024
Todo lo que debe saber sobre el embrague magnético del compresor de CA del coche
Este artículo presenta los componentes del embrague magnético del compresor y su principio de funcionamiento, así como varios parámetros importantes. Además, también le brindamos algunas experiencias sobre cómo lidiar con la quema de los embragues del compresor del aire acondicionado.
-
02/17/2024
Método de cableado del relé PTC de nevera
El relé PTC (coeficiente de temperatura positivo) está conectado directamente en serie con el devanado secundario (devanado de arranque) y en paralelo con el devanado principal del motor.
-
08/04/2023
Aire acondicionado Mitsubishi vs Panasonic
El verano es tan difícil de pasar que las personas sin aire acondicionado son como peces fuera del agua. Es fundamental elegir un buen aire acondicionado.
-
12/05/2023
Principios y diferencias de los transmisores de 2, 3 y 4 hilos
Los transmisores de 2, 3 y 4 hilos se refieren a transmisores cuyas salidas son señales analógicas de corriente CC.
-
07/29/2023
Compresor Scroll Vs. Compresor rotativo para CA
El compresor scrollue inventado en 1905 por el francés Copeland. Creó la compañía Copeland en los Estados Unidos, donde se utilizan principalmente acondicionadores de aire de agua
-
01/08/2024
¿Por qué vibra el servomotor?
¿En qué casos vibrará un servomotor? ¿Qué pasa si el servomotor vibra? ¿Cómo podemos solucionar los problemas causados por la vibración? Este artículo explicará varias razones para esto.
-
08/08/2022
Motor de inducción de jaula de ardilla frente a motor de inducción de rotor bobinado: Estructura del rotor, ventajas e inconvenientes
El motor de inducción trifásico consta de dos partes básicas: el estator y el rotor. El estator es la parte fija del motor y se utiliza para generar un campo magnético giratorio.
-
08/08/2023
Método de cálculo del peso por metro de tubo de cobre para aire acondicionado
Método de cálculo del peso por metro de tubería de cobre para aire acondicionado.